An In Vitro Study to Compare the Shear Bond Strength of Orthodontic Brackets Bonded to Permanent Teeth by Using Conventional Acid-Etching and Self-Etching Primers
Objectives: The objective of the present study was to evaluate and compare the bond strength of orthodontic brackets bonded to permanent teeth with a conventional acid-etching and self-etching primer systems. Also, the study aims to evaluate the mode of bond failure after debonding the brackets. Mat...
Guardado en:
Autor principal: | |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Wolters Kluwer Medknow Publications
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/f5d98344f2fb408a9597e15b734f2f59 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:f5d98344f2fb408a9597e15b734f2f59 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:f5d98344f2fb408a9597e15b734f2f592021-11-12T10:10:06ZAn In Vitro Study to Compare the Shear Bond Strength of Orthodontic Brackets Bonded to Permanent Teeth by Using Conventional Acid-Etching and Self-Etching Primers2155-821310.4103/denthyp.denthyp_41_21https://doaj.org/article/f5d98344f2fb408a9597e15b734f2f592021-01-01T00:00:00Zhttp://www.dentalhypotheses.com/article.asp?issn=2155-8213;year=2021;volume=12;issue=3;spage=155;epage=160;aulast=Bilalhttps://doaj.org/toc/2155-8213Objectives: The objective of the present study was to evaluate and compare the bond strength of orthodontic brackets bonded to permanent teeth with a conventional acid-etching and self-etching primer systems. Also, the study aims to evaluate the mode of bond failure after debonding the brackets. Materials and Methods: It was an experimental study. Fifty extracted permanent premolars were collected, checked, and cleaned. Teeth were split equally into two groups, group A and B. Orthodontic brackets were bonded using conventional acid-etching and self-etching primer systems for group A and B, respectively. Shear bond strength (SBS) was measured with a universal testing machine, and the mode of bracket-adhesive failure was determined by using adhesive remnant index (ARI). Data were analyzed with a statistical software. Independent sample t-test was used to compare the SBS and Mann–Whitney U test was used to assess whether there is a significant difference of ARI score between the groups. Results: Although the SBS with self-etching primer was within clinically acceptable range, the overall mean SBS for group A (14.71 MPa) was significantly greater than group B (9.24 MPa) (P = 0.024). There was no significant difference in ARI scores between conventional acid-etching and self-etching groups (P = 0.801). Conclusion: The SBS of the conventional acid-etching was significantly higher than the self-etching primer. The SBS of self-etch was within the acceptable range to withstand the forces of mastication. The majority of the brackets recorded ARI score of 1 indicating a cohesive failure with no significant difference between acid-etch and self-etch groups.Rabia BilalWolters Kluwer Medknow Publicationsarticleadhesive remnant indexconventional acid-etchingdentistryself-etching primerorthodonticsshear bond strengthuniversal testing machineDentistryRK1-715ENDental Hypotheses, Vol 12, Iss 3, Pp 155-160 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
adhesive remnant index conventional acid-etching dentistry self-etching primer orthodontics shear bond strength universal testing machine Dentistry RK1-715 |
spellingShingle |
adhesive remnant index conventional acid-etching dentistry self-etching primer orthodontics shear bond strength universal testing machine Dentistry RK1-715 Rabia Bilal An In Vitro Study to Compare the Shear Bond Strength of Orthodontic Brackets Bonded to Permanent Teeth by Using Conventional Acid-Etching and Self-Etching Primers |
description |
Objectives: The objective of the present study was to evaluate and compare the bond strength of orthodontic brackets bonded to permanent teeth with a conventional acid-etching and self-etching primer systems. Also, the study aims to evaluate the mode of bond failure after debonding the brackets. Materials and Methods: It was an experimental study. Fifty extracted permanent premolars were collected, checked, and cleaned. Teeth were split equally into two groups, group A and B. Orthodontic brackets were bonded using conventional acid-etching and self-etching primer systems for group A and B, respectively. Shear bond strength (SBS) was measured with a universal testing machine, and the mode of bracket-adhesive failure was determined by using adhesive remnant index (ARI). Data were analyzed with a statistical software. Independent sample t-test was used to compare the SBS and Mann–Whitney U test was used to assess whether there is a significant difference of ARI score between the groups. Results: Although the SBS with self-etching primer was within clinically acceptable range, the overall mean SBS for group A (14.71 MPa) was significantly greater than group B (9.24 MPa) (P = 0.024). There was no significant difference in ARI scores between conventional acid-etching and self-etching groups (P = 0.801). Conclusion: The SBS of the conventional acid-etching was significantly higher than the self-etching primer. The SBS of self-etch was within the acceptable range to withstand the forces of mastication. The majority of the brackets recorded ARI score of 1 indicating a cohesive failure with no significant difference between acid-etch and self-etch groups. |
format |
article |
author |
Rabia Bilal |
author_facet |
Rabia Bilal |
author_sort |
Rabia Bilal |
title |
An In Vitro Study to Compare the Shear Bond Strength of Orthodontic Brackets Bonded to Permanent Teeth by Using Conventional Acid-Etching and Self-Etching Primers |
title_short |
An In Vitro Study to Compare the Shear Bond Strength of Orthodontic Brackets Bonded to Permanent Teeth by Using Conventional Acid-Etching and Self-Etching Primers |
title_full |
An In Vitro Study to Compare the Shear Bond Strength of Orthodontic Brackets Bonded to Permanent Teeth by Using Conventional Acid-Etching and Self-Etching Primers |
title_fullStr |
An In Vitro Study to Compare the Shear Bond Strength of Orthodontic Brackets Bonded to Permanent Teeth by Using Conventional Acid-Etching and Self-Etching Primers |
title_full_unstemmed |
An In Vitro Study to Compare the Shear Bond Strength of Orthodontic Brackets Bonded to Permanent Teeth by Using Conventional Acid-Etching and Self-Etching Primers |
title_sort |
in vitro study to compare the shear bond strength of orthodontic brackets bonded to permanent teeth by using conventional acid-etching and self-etching primers |
publisher |
Wolters Kluwer Medknow Publications |
publishDate |
2021 |
url |
https://doaj.org/article/f5d98344f2fb408a9597e15b734f2f59 |
work_keys_str_mv |
AT rabiabilal aninvitrostudytocomparetheshearbondstrengthoforthodonticbracketsbondedtopermanentteethbyusingconventionalacidetchingandselfetchingprimers AT rabiabilal invitrostudytocomparetheshearbondstrengthoforthodonticbracketsbondedtopermanentteethbyusingconventionalacidetchingandselfetchingprimers |
_version_ |
1718431026349342720 |