A new lens for observing fundus with a noncontact wide-angle viewing system

Mihori Kita, Yukiko Fujii, Sachiyo Hama Department of Ophthalmology, National Organization Kyoto Medical Center, Kyoto, Japan Abstract: Drying of the cornea during surgery, which causes poor visibility of the fundus, is one of the most serious problems when using a noncontact-type wide-angle viewi...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Kita M, Fujii Y, Hama S
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2017
Materias:
Acceso en línea:https://doaj.org/article/f65fd0dda9464575b3fbbc88a277ff85
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:f65fd0dda9464575b3fbbc88a277ff85
record_format dspace
spelling oai:doaj.org-article:f65fd0dda9464575b3fbbc88a277ff852021-12-02T02:40:17ZA new lens for observing fundus with a noncontact wide-angle viewing system1177-5483https://doaj.org/article/f65fd0dda9464575b3fbbc88a277ff852017-07-01T00:00:00Zhttps://www.dovepress.com/a-new-lens-for-observing-fundus-with-a-noncontact-wide-angle-viewing-s-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Mihori Kita, Yukiko Fujii, Sachiyo Hama Department of Ophthalmology, National Organization Kyoto Medical Center, Kyoto, Japan Abstract: Drying of the cornea during surgery, which causes poor visibility of the fundus, is one of the most serious problems when using a noncontact-type wide-angle viewing system. This study used a newly commercialized lens for observing the fundus with a noncontact wide-angle viewing system. The lens used has a very thin meniscus made of polymethyl methacrylate and a large outer diameter. Following the application of viscoelastic material, the lens can be put on the cornea without using a contact lens fixation ring. The larger diameter and lightweight characteristics of the new lens contributed to the overall stabilization. The smooth surface of this lens was able to achieve an intraoperative view of good quality not only during vitrectomy but also during scleral buckling procedures. Keywords: contact lens, observing fundus, vitrectomy, scleral buckling, noncontact wide-angle viewing systemKita MFujii YHama SDove Medical Pressarticlecontact lensobserving fundusvitrectomyscleral bucklingnoncontact wide-angle viewing systemOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 11, Pp 1239-1244 (2017)
institution DOAJ
collection DOAJ
language EN
topic contact lens
observing fundus
vitrectomy
scleral buckling
noncontact wide-angle viewing system
Ophthalmology
RE1-994
spellingShingle contact lens
observing fundus
vitrectomy
scleral buckling
noncontact wide-angle viewing system
Ophthalmology
RE1-994
Kita M
Fujii Y
Hama S
A new lens for observing fundus with a noncontact wide-angle viewing system
description Mihori Kita, Yukiko Fujii, Sachiyo Hama Department of Ophthalmology, National Organization Kyoto Medical Center, Kyoto, Japan Abstract: Drying of the cornea during surgery, which causes poor visibility of the fundus, is one of the most serious problems when using a noncontact-type wide-angle viewing system. This study used a newly commercialized lens for observing the fundus with a noncontact wide-angle viewing system. The lens used has a very thin meniscus made of polymethyl methacrylate and a large outer diameter. Following the application of viscoelastic material, the lens can be put on the cornea without using a contact lens fixation ring. The larger diameter and lightweight characteristics of the new lens contributed to the overall stabilization. The smooth surface of this lens was able to achieve an intraoperative view of good quality not only during vitrectomy but also during scleral buckling procedures. Keywords: contact lens, observing fundus, vitrectomy, scleral buckling, noncontact wide-angle viewing system
format article
author Kita M
Fujii Y
Hama S
author_facet Kita M
Fujii Y
Hama S
author_sort Kita M
title A new lens for observing fundus with a noncontact wide-angle viewing system
title_short A new lens for observing fundus with a noncontact wide-angle viewing system
title_full A new lens for observing fundus with a noncontact wide-angle viewing system
title_fullStr A new lens for observing fundus with a noncontact wide-angle viewing system
title_full_unstemmed A new lens for observing fundus with a noncontact wide-angle viewing system
title_sort new lens for observing fundus with a noncontact wide-angle viewing system
publisher Dove Medical Press
publishDate 2017
url https://doaj.org/article/f65fd0dda9464575b3fbbc88a277ff85
work_keys_str_mv AT kitam anewlensforobservingfunduswithanoncontactwideangleviewingsystem
AT fujiiy anewlensforobservingfunduswithanoncontactwideangleviewingsystem
AT hamas anewlensforobservingfunduswithanoncontactwideangleviewingsystem
AT kitam newlensforobservingfunduswithanoncontactwideangleviewingsystem
AT fujiiy newlensforobservingfunduswithanoncontactwideangleviewingsystem
AT hamas newlensforobservingfunduswithanoncontactwideangleviewingsystem
_version_ 1718402323543228416