A Novel Radiofrequency Device to Monitor Changes in Pulmonary Fluid in Dialysis Patients

Jeffrey J Connaire,1 Matthew L Sundermann,2 Ramu Perumal,2 Charles A Herzog3 1Davita Clinical Research, Minneapolis, MN, USA; 2ZOLL, Pittsburgh, PA, USA; 3Cardiology Division, Department of Internal Medicine, Hennepin Healthcare/University of Minnesota, Minneapolis, MN, USACorrespondence: Jeffrey J...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Connaire JJ, Sundermann ML, Perumal R, Herzog CA
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2020
Materias:
Acceso en línea:https://doaj.org/article/f6929f42998c48888929a10e87ffce1e
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:f6929f42998c48888929a10e87ffce1e
record_format dspace
spelling oai:doaj.org-article:f6929f42998c48888929a10e87ffce1e2021-12-02T12:13:47ZA Novel Radiofrequency Device to Monitor Changes in Pulmonary Fluid in Dialysis Patients1179-1470https://doaj.org/article/f6929f42998c48888929a10e87ffce1e2020-11-01T00:00:00Zhttps://www.dovepress.com/a-novel-radiofrequency-device-to-monitor-changes-in-pulmonary-fluid-in-peer-reviewed-article-MDERhttps://doaj.org/toc/1179-1470Jeffrey J Connaire,1 Matthew L Sundermann,2 Ramu Perumal,2 Charles A Herzog3 1Davita Clinical Research, Minneapolis, MN, USA; 2ZOLL, Pittsburgh, PA, USA; 3Cardiology Division, Department of Internal Medicine, Hennepin Healthcare/University of Minnesota, Minneapolis, MN, USACorrespondence: Jeffrey J ConnaireDaVita Clinical Research, 825 S 8 th St, Suite 300, Minneapolis, MN 55404, USATel +1 612 202-1581Fax +1 866 852-3241Email Jeffrey.Connaire@davita.comBackground and Objectives: Fluid monitoring is an important management strategy in patients with chronic kidney disease (CKD) and heart failure (HF). The μCor™ Heart Failure and Arrhythmia Management System uses a radiofrequency-based thoracic fluid index (TFI) to track pulmonary edema. During hemodialysis, the acute removal of fluid through ultrafiltration offers a model for measuring a patient’s fluid status. The objective of the study was to assess the relationship between the device measured TFI and ultrafiltration volume (UFV).Design, Setting, Participants, and Measurements: Patients undergoing chronic dialysis with and without heart failure were enrolled in the study. The relationship between TFI and UFV in each individual subject was assessed by calculating the Pearson correlation coefficient (r). The average correlation across all subjects was calculated through the use of the Fisher’s z transform. Responder analysis was performed to assess the magnitude of change in TFI before and after dialysis.Results: Twenty subjects were enrolled in the trial. The mean volume of fluid removal was 3.63 L (SD 0.88 L). The mean correlation based on Fisher’s transform was 0.95 CI (0.92– 0.99). Responder analysis showed that the mean reduction of TFI after dialysis was 5.5% ± 3.8.Conclusion: The μCor system provides radiofrequency-based measurements of thoracic fluid which correlate well with total body fluid removal in a real-world setting. Fluid management based on the radar-derived TFI may provide benefits to dialysis patients and serves as a potential model for pulmonary edema common to the clinical course of heart failure.Keywords: heart failure, total body fluid monitoring, dialysis, wearables, ultrafiltrationConnaire JJSundermann MLPerumal RHerzog CADove Medical Pressarticleheart failuretotal body fluid monitoringdialysiswearablesultrafiltrationMedical technologyR855-855.5ENMedical Devices: Evidence and Research, Vol Volume 13, Pp 377-383 (2020)
institution DOAJ
collection DOAJ
language EN
topic heart failure
total body fluid monitoring
dialysis
wearables
ultrafiltration
Medical technology
R855-855.5
spellingShingle heart failure
total body fluid monitoring
dialysis
wearables
ultrafiltration
Medical technology
R855-855.5
Connaire JJ
Sundermann ML
Perumal R
Herzog CA
A Novel Radiofrequency Device to Monitor Changes in Pulmonary Fluid in Dialysis Patients
description Jeffrey J Connaire,1 Matthew L Sundermann,2 Ramu Perumal,2 Charles A Herzog3 1Davita Clinical Research, Minneapolis, MN, USA; 2ZOLL, Pittsburgh, PA, USA; 3Cardiology Division, Department of Internal Medicine, Hennepin Healthcare/University of Minnesota, Minneapolis, MN, USACorrespondence: Jeffrey J ConnaireDaVita Clinical Research, 825 S 8 th St, Suite 300, Minneapolis, MN 55404, USATel +1 612 202-1581Fax +1 866 852-3241Email Jeffrey.Connaire@davita.comBackground and Objectives: Fluid monitoring is an important management strategy in patients with chronic kidney disease (CKD) and heart failure (HF). The μCor™ Heart Failure and Arrhythmia Management System uses a radiofrequency-based thoracic fluid index (TFI) to track pulmonary edema. During hemodialysis, the acute removal of fluid through ultrafiltration offers a model for measuring a patient’s fluid status. The objective of the study was to assess the relationship between the device measured TFI and ultrafiltration volume (UFV).Design, Setting, Participants, and Measurements: Patients undergoing chronic dialysis with and without heart failure were enrolled in the study. The relationship between TFI and UFV in each individual subject was assessed by calculating the Pearson correlation coefficient (r). The average correlation across all subjects was calculated through the use of the Fisher’s z transform. Responder analysis was performed to assess the magnitude of change in TFI before and after dialysis.Results: Twenty subjects were enrolled in the trial. The mean volume of fluid removal was 3.63 L (SD 0.88 L). The mean correlation based on Fisher’s transform was 0.95 CI (0.92– 0.99). Responder analysis showed that the mean reduction of TFI after dialysis was 5.5% ± 3.8.Conclusion: The μCor system provides radiofrequency-based measurements of thoracic fluid which correlate well with total body fluid removal in a real-world setting. Fluid management based on the radar-derived TFI may provide benefits to dialysis patients and serves as a potential model for pulmonary edema common to the clinical course of heart failure.Keywords: heart failure, total body fluid monitoring, dialysis, wearables, ultrafiltration
format article
author Connaire JJ
Sundermann ML
Perumal R
Herzog CA
author_facet Connaire JJ
Sundermann ML
Perumal R
Herzog CA
author_sort Connaire JJ
title A Novel Radiofrequency Device to Monitor Changes in Pulmonary Fluid in Dialysis Patients
title_short A Novel Radiofrequency Device to Monitor Changes in Pulmonary Fluid in Dialysis Patients
title_full A Novel Radiofrequency Device to Monitor Changes in Pulmonary Fluid in Dialysis Patients
title_fullStr A Novel Radiofrequency Device to Monitor Changes in Pulmonary Fluid in Dialysis Patients
title_full_unstemmed A Novel Radiofrequency Device to Monitor Changes in Pulmonary Fluid in Dialysis Patients
title_sort novel radiofrequency device to monitor changes in pulmonary fluid in dialysis patients
publisher Dove Medical Press
publishDate 2020
url https://doaj.org/article/f6929f42998c48888929a10e87ffce1e
work_keys_str_mv AT connairejj anovelradiofrequencydevicetomonitorchangesinpulmonaryfluidindialysispatients
AT sundermannml anovelradiofrequencydevicetomonitorchangesinpulmonaryfluidindialysispatients
AT perumalr anovelradiofrequencydevicetomonitorchangesinpulmonaryfluidindialysispatients
AT herzogca anovelradiofrequencydevicetomonitorchangesinpulmonaryfluidindialysispatients
AT connairejj novelradiofrequencydevicetomonitorchangesinpulmonaryfluidindialysispatients
AT sundermannml novelradiofrequencydevicetomonitorchangesinpulmonaryfluidindialysispatients
AT perumalr novelradiofrequencydevicetomonitorchangesinpulmonaryfluidindialysispatients
AT herzogca novelradiofrequencydevicetomonitorchangesinpulmonaryfluidindialysispatients
_version_ 1718394609211539456