Physiologic load-bearing characteristics of autografts, allografts, and polymer-based scaffolds in a critical sized segmental defect of long bone: an experimental study
LF Amorosa,1 CH Lee,2 AB Aydemir,1 S Nizami,1 A Hsu,1 NR Patel,1 TR Gardner,1 A Navalgund,3 D-G Kim,3 SH Park,4 JJ Mao,2 FY Lee11Center for Orthopaedic Research, Columbia University Medical Center, New York, NY, 2College of Dental Medicine, Columbia University Medical Center, New York, NY, 3Orthodon...
Guardado en:
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2013
|
Materias: | |
Acceso en línea: | https://doaj.org/article/f6c46e023e9c4aa78227925019ac8039 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:f6c46e023e9c4aa78227925019ac8039 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:f6c46e023e9c4aa78227925019ac80392021-12-02T08:45:15ZPhysiologic load-bearing characteristics of autografts, allografts, and polymer-based scaffolds in a critical sized segmental defect of long bone: an experimental study1176-91141178-2013https://doaj.org/article/f6c46e023e9c4aa78227925019ac80392013-04-01T00:00:00Zhttp://www.dovepress.com/physiologic-load-bearing-characteristics-of-autografts-allografts-and--a12866https://doaj.org/toc/1176-9114https://doaj.org/toc/1178-2013LF Amorosa,1 CH Lee,2 AB Aydemir,1 S Nizami,1 A Hsu,1 NR Patel,1 TR Gardner,1 A Navalgund,3 D-G Kim,3 SH Park,4 JJ Mao,2 FY Lee11Center for Orthopaedic Research, Columbia University Medical Center, New York, NY, 2College of Dental Medicine, Columbia University Medical Center, New York, NY, 3Orthodontics, College of Dentistry, Ohio State University, Columbus, OH, 4Department of Orthopaedic Surgery, University of California at Los Angeles Medical Center, Los Angeles, CA, USABackground: To address the challenge of treating critical sized intercalary defects, we hypothesized that under physiologic cyclic loading, autografts, allografts, and scaffolds loaded with and without human mesenchymal stem cells (hMSCs) would have different biomechanical characteristics.Methods: Using a rat femoral defect model, 46 rats were assigned to four groups, ie, autograft (n = 12), allograft (n = 10), scaffold (n = 13), and scaffold with hMSCs (n = 11). The scaffold groups used a 5 mm segment of scaffold composed of 80% poly-ε-caprolactone and 20% hydroxyapatite. Rats were sacrificed 4 months postoperatively, and the repairs were assessed radiographically and biomechanically.Results: Autograft and allograft groups exhibited the most bridging callus, while the scaffold/hMSCs group had more callus than the scaffold repairs. Although signs of radiographic healing did not accurately reflect restoration of mechanical properties, addition of hMSCs on the scaffold enhanced bone formation. The scaffold alone group had significantly lower elastic and viscous stiffness and higher phase angles than other repairs and the contralateral controls. Addition of hMSCs increased the elastic and viscous stiffness of the repair, while decreasing the phase angle.Conclusion: Further comparative analysis is needed to optimize clinical use of scaffolds and hMSCs for critical sized defect repairs. However, our results suggest that addition of hMSCs to scaffolds enhances mechanical simulation of native host bone.Keywords: fracture healing, scaffolds, human mesenchymal stem cells, tissue engineeringAmorosa LFLee CHAydemir ABNizami SHsu APatel NRGardner TRNavalgund AKim D-GPark SHMao JJLee FYDove Medical PressarticleMedicine (General)R5-920ENInternational Journal of Nanomedicine, Vol 2013, Iss default, Pp 1637-1643 (2013) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine (General) R5-920 |
spellingShingle |
Medicine (General) R5-920 Amorosa LF Lee CH Aydemir AB Nizami S Hsu A Patel NR Gardner TR Navalgund A Kim D-G Park SH Mao JJ Lee FY Physiologic load-bearing characteristics of autografts, allografts, and polymer-based scaffolds in a critical sized segmental defect of long bone: an experimental study |
description |
LF Amorosa,1 CH Lee,2 AB Aydemir,1 S Nizami,1 A Hsu,1 NR Patel,1 TR Gardner,1 A Navalgund,3 D-G Kim,3 SH Park,4 JJ Mao,2 FY Lee11Center for Orthopaedic Research, Columbia University Medical Center, New York, NY, 2College of Dental Medicine, Columbia University Medical Center, New York, NY, 3Orthodontics, College of Dentistry, Ohio State University, Columbus, OH, 4Department of Orthopaedic Surgery, University of California at Los Angeles Medical Center, Los Angeles, CA, USABackground: To address the challenge of treating critical sized intercalary defects, we hypothesized that under physiologic cyclic loading, autografts, allografts, and scaffolds loaded with and without human mesenchymal stem cells (hMSCs) would have different biomechanical characteristics.Methods: Using a rat femoral defect model, 46 rats were assigned to four groups, ie, autograft (n = 12), allograft (n = 10), scaffold (n = 13), and scaffold with hMSCs (n = 11). The scaffold groups used a 5 mm segment of scaffold composed of 80% poly-ε-caprolactone and 20% hydroxyapatite. Rats were sacrificed 4 months postoperatively, and the repairs were assessed radiographically and biomechanically.Results: Autograft and allograft groups exhibited the most bridging callus, while the scaffold/hMSCs group had more callus than the scaffold repairs. Although signs of radiographic healing did not accurately reflect restoration of mechanical properties, addition of hMSCs on the scaffold enhanced bone formation. The scaffold alone group had significantly lower elastic and viscous stiffness and higher phase angles than other repairs and the contralateral controls. Addition of hMSCs increased the elastic and viscous stiffness of the repair, while decreasing the phase angle.Conclusion: Further comparative analysis is needed to optimize clinical use of scaffolds and hMSCs for critical sized defect repairs. However, our results suggest that addition of hMSCs to scaffolds enhances mechanical simulation of native host bone.Keywords: fracture healing, scaffolds, human mesenchymal stem cells, tissue engineering |
format |
article |
author |
Amorosa LF Lee CH Aydemir AB Nizami S Hsu A Patel NR Gardner TR Navalgund A Kim D-G Park SH Mao JJ Lee FY |
author_facet |
Amorosa LF Lee CH Aydemir AB Nizami S Hsu A Patel NR Gardner TR Navalgund A Kim D-G Park SH Mao JJ Lee FY |
author_sort |
Amorosa LF |
title |
Physiologic load-bearing characteristics of autografts, allografts, and polymer-based scaffolds in a critical sized segmental defect of long bone: an experimental study |
title_short |
Physiologic load-bearing characteristics of autografts, allografts, and polymer-based scaffolds in a critical sized segmental defect of long bone: an experimental study |
title_full |
Physiologic load-bearing characteristics of autografts, allografts, and polymer-based scaffolds in a critical sized segmental defect of long bone: an experimental study |
title_fullStr |
Physiologic load-bearing characteristics of autografts, allografts, and polymer-based scaffolds in a critical sized segmental defect of long bone: an experimental study |
title_full_unstemmed |
Physiologic load-bearing characteristics of autografts, allografts, and polymer-based scaffolds in a critical sized segmental defect of long bone: an experimental study |
title_sort |
physiologic load-bearing characteristics of autografts, allografts, and polymer-based scaffolds in a critical sized segmental defect of long bone: an experimental study |
publisher |
Dove Medical Press |
publishDate |
2013 |
url |
https://doaj.org/article/f6c46e023e9c4aa78227925019ac8039 |
work_keys_str_mv |
AT amorosalf physiologicloadbearingcharacteristicsofautograftsallograftsandpolymerbasedscaffoldsinacriticalsizedsegmentaldefectoflongboneanexperimentalstudy AT leech physiologicloadbearingcharacteristicsofautograftsallograftsandpolymerbasedscaffoldsinacriticalsizedsegmentaldefectoflongboneanexperimentalstudy AT aydemirab physiologicloadbearingcharacteristicsofautograftsallograftsandpolymerbasedscaffoldsinacriticalsizedsegmentaldefectoflongboneanexperimentalstudy AT nizamis physiologicloadbearingcharacteristicsofautograftsallograftsandpolymerbasedscaffoldsinacriticalsizedsegmentaldefectoflongboneanexperimentalstudy AT hsua physiologicloadbearingcharacteristicsofautograftsallograftsandpolymerbasedscaffoldsinacriticalsizedsegmentaldefectoflongboneanexperimentalstudy AT patelnr physiologicloadbearingcharacteristicsofautograftsallograftsandpolymerbasedscaffoldsinacriticalsizedsegmentaldefectoflongboneanexperimentalstudy AT gardnertr physiologicloadbearingcharacteristicsofautograftsallograftsandpolymerbasedscaffoldsinacriticalsizedsegmentaldefectoflongboneanexperimentalstudy AT navalgunda physiologicloadbearingcharacteristicsofautograftsallograftsandpolymerbasedscaffoldsinacriticalsizedsegmentaldefectoflongboneanexperimentalstudy AT kimdg physiologicloadbearingcharacteristicsofautograftsallograftsandpolymerbasedscaffoldsinacriticalsizedsegmentaldefectoflongboneanexperimentalstudy AT parksh physiologicloadbearingcharacteristicsofautograftsallograftsandpolymerbasedscaffoldsinacriticalsizedsegmentaldefectoflongboneanexperimentalstudy AT maojj physiologicloadbearingcharacteristicsofautograftsallograftsandpolymerbasedscaffoldsinacriticalsizedsegmentaldefectoflongboneanexperimentalstudy AT leefy physiologicloadbearingcharacteristicsofautograftsallograftsandpolymerbasedscaffoldsinacriticalsizedsegmentaldefectoflongboneanexperimentalstudy |
_version_ |
1718398399672221696 |