Effects of temperature and fluid media on the scroll width size of the Descemet’s membrane endothelial keratoplasty (DMEK) donor graft

Ellen H Koo,1 Allen O Eghrari,2 Ryan S Meshkin,2 Wei Shi,1 William J Feuer,1 Karen G DeMarco,3 Arthur C Kurz3 1Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, 2Wilmer Eye Institute, Johns Hopkins University School of Medicine, 3KeraLink International, Baltimor...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Koo EH, Eghrari AO, Meshkin RS, Shi W, Feuer WJ, DeMarco KG, Kurz AC
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2017
Materias:
Acceso en línea:https://doaj.org/article/f6c69529d07e469ba4ff127d3046d57b
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:f6c69529d07e469ba4ff127d3046d57b
record_format dspace
spelling oai:doaj.org-article:f6c69529d07e469ba4ff127d3046d57b2021-12-02T01:38:57ZEffects of temperature and fluid media on the scroll width size of the Descemet’s membrane endothelial keratoplasty (DMEK) donor graft1177-5483https://doaj.org/article/f6c69529d07e469ba4ff127d3046d57b2017-09-01T00:00:00Zhttps://www.dovepress.com/effects-of-temperature-and-fluid-media-on-the-scroll-width-size-of-the-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Ellen H Koo,1 Allen O Eghrari,2 Ryan S Meshkin,2 Wei Shi,1 William J Feuer,1 Karen G DeMarco,3 Arthur C Kurz3 1Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, 2Wilmer Eye Institute, Johns Hopkins University School of Medicine, 3KeraLink International, Baltimore, MD, USA Aim: Our study was conducted to evaluate whether higher temperature leads to increased – or wider – scroll widths of the Descemet’s membrane endothelial keratoplasty (DMEK) donor graft.Purpose: To investigate the effects of temperature and fluid media on the DMEK donor graft scroll widths.Materials and methods: This research work was a laboratory investigation. Baseline cell count was taken via specular microscopy for the donor corneas at room temperature (20°C–25°C). The endothelium sides of the donor corneas were stained with Trypan Blue Solution 0.4% for 30 s, and the Descemet’s membranes were stripped. The DMEK donor grafts were placed into three different fluid media – Optisol®, Balanced Salt Solution (BSS), and BSS PLUS® (BSS Plus). The DMEK donor grafts were then transferred into cold temperature (4°C) for 60 min, after which the donor grafts’ scroll widths were examined and measured. The donor grafts were then warmed in the incubator and brought to physiological temperature (35°C–37°C), and their scroll widths were examined and measured again.Results: In 30 measurements of ten tissues across three temperature and fluid conditions, the average scroll width measured 1.73 mm, ranging from 1.1 to 2.9 mm. In a mixed linear model, the scroll widths increased with temperature (P=0.02). There was no significant difference in scroll widths among the three solutions (P=0.84, mixed linear model).Conclusion: We observed an increase in DMEK donor graft scroll widths with higher temperatures. The usage of BSS Plus as media solution could also lead to smaller DMEK donor graft scroll widths, compared with BSS, but our study does not establish this. Keywords: DMEK, graft scroll, graft conformation, DMEK scroll, DMEK graft Koo EHEghrari AOMeshkin RSShi WFeuer WJDeMarco KGKurz ACDove Medical PressarticleDMEKgraft scrollgraft conformationDMEK scrollDMEK graftOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 11, Pp 1611-1615 (2017)
institution DOAJ
collection DOAJ
language EN
topic DMEK
graft scroll
graft conformation
DMEK scroll
DMEK graft
Ophthalmology
RE1-994
spellingShingle DMEK
graft scroll
graft conformation
DMEK scroll
DMEK graft
Ophthalmology
RE1-994
Koo EH
Eghrari AO
Meshkin RS
Shi W
Feuer WJ
DeMarco KG
Kurz AC
Effects of temperature and fluid media on the scroll width size of the Descemet’s membrane endothelial keratoplasty (DMEK) donor graft
description Ellen H Koo,1 Allen O Eghrari,2 Ryan S Meshkin,2 Wei Shi,1 William J Feuer,1 Karen G DeMarco,3 Arthur C Kurz3 1Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, 2Wilmer Eye Institute, Johns Hopkins University School of Medicine, 3KeraLink International, Baltimore, MD, USA Aim: Our study was conducted to evaluate whether higher temperature leads to increased – or wider – scroll widths of the Descemet’s membrane endothelial keratoplasty (DMEK) donor graft.Purpose: To investigate the effects of temperature and fluid media on the DMEK donor graft scroll widths.Materials and methods: This research work was a laboratory investigation. Baseline cell count was taken via specular microscopy for the donor corneas at room temperature (20°C–25°C). The endothelium sides of the donor corneas were stained with Trypan Blue Solution 0.4% for 30 s, and the Descemet’s membranes were stripped. The DMEK donor grafts were placed into three different fluid media – Optisol®, Balanced Salt Solution (BSS), and BSS PLUS® (BSS Plus). The DMEK donor grafts were then transferred into cold temperature (4°C) for 60 min, after which the donor grafts’ scroll widths were examined and measured. The donor grafts were then warmed in the incubator and brought to physiological temperature (35°C–37°C), and their scroll widths were examined and measured again.Results: In 30 measurements of ten tissues across three temperature and fluid conditions, the average scroll width measured 1.73 mm, ranging from 1.1 to 2.9 mm. In a mixed linear model, the scroll widths increased with temperature (P=0.02). There was no significant difference in scroll widths among the three solutions (P=0.84, mixed linear model).Conclusion: We observed an increase in DMEK donor graft scroll widths with higher temperatures. The usage of BSS Plus as media solution could also lead to smaller DMEK donor graft scroll widths, compared with BSS, but our study does not establish this. Keywords: DMEK, graft scroll, graft conformation, DMEK scroll, DMEK graft 
format article
author Koo EH
Eghrari AO
Meshkin RS
Shi W
Feuer WJ
DeMarco KG
Kurz AC
author_facet Koo EH
Eghrari AO
Meshkin RS
Shi W
Feuer WJ
DeMarco KG
Kurz AC
author_sort Koo EH
title Effects of temperature and fluid media on the scroll width size of the Descemet’s membrane endothelial keratoplasty (DMEK) donor graft
title_short Effects of temperature and fluid media on the scroll width size of the Descemet’s membrane endothelial keratoplasty (DMEK) donor graft
title_full Effects of temperature and fluid media on the scroll width size of the Descemet’s membrane endothelial keratoplasty (DMEK) donor graft
title_fullStr Effects of temperature and fluid media on the scroll width size of the Descemet’s membrane endothelial keratoplasty (DMEK) donor graft
title_full_unstemmed Effects of temperature and fluid media on the scroll width size of the Descemet’s membrane endothelial keratoplasty (DMEK) donor graft
title_sort effects of temperature and fluid media on the scroll width size of the descemet’s membrane endothelial keratoplasty (dmek) donor graft
publisher Dove Medical Press
publishDate 2017
url https://doaj.org/article/f6c69529d07e469ba4ff127d3046d57b
work_keys_str_mv AT kooeh effectsoftemperatureandfluidmediaonthescrollwidthsizeofthedescemetrsquosmembraneendothelialkeratoplastydmekdonorgraft
AT eghrariao effectsoftemperatureandfluidmediaonthescrollwidthsizeofthedescemetrsquosmembraneendothelialkeratoplastydmekdonorgraft
AT meshkinrs effectsoftemperatureandfluidmediaonthescrollwidthsizeofthedescemetrsquosmembraneendothelialkeratoplastydmekdonorgraft
AT shiw effectsoftemperatureandfluidmediaonthescrollwidthsizeofthedescemetrsquosmembraneendothelialkeratoplastydmekdonorgraft
AT feuerwj effectsoftemperatureandfluidmediaonthescrollwidthsizeofthedescemetrsquosmembraneendothelialkeratoplastydmekdonorgraft
AT demarcokg effectsoftemperatureandfluidmediaonthescrollwidthsizeofthedescemetrsquosmembraneendothelialkeratoplastydmekdonorgraft
AT kurzac effectsoftemperatureandfluidmediaonthescrollwidthsizeofthedescemetrsquosmembraneendothelialkeratoplastydmekdonorgraft
_version_ 1718402992485433344