Hanefi Cakir1, Canan Asli Utine2, Mehmet Baykara31Turkiye Hospital Eye Clinic, Istanbul, 2Department of Ophthalmology, Yeditepe University, Istanbul, 3Department of Ophthalmology, Uludag University, Bursa, TurkeyPurpose: To report the use of intracorneal ring segment (ICRS) implantation in a case of...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Cakir H, Utine CA, Baykara M
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2011
Materias:
Acceso en línea:https://doaj.org/article/f747ef086e7945b0bf7e410ae5b60df3
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:f747ef086e7945b0bf7e410ae5b60df3
record_format dspace
spelling oai:doaj.org-article:f747ef086e7945b0bf7e410ae5b60df32021-12-02T06:15:22ZIntracorneal ring implantation using Intralase® with partial coverage of the cone in a patient after an alkaline injury1177-54671177-5483https://doaj.org/article/f747ef086e7945b0bf7e410ae5b60df32011-11-01T00:00:00Zhttp://www.dovepress.com/intracorneal-ring-implantation-using-intralasereg-with-partial-coverag-a8668https://doaj.org/toc/1177-5467https://doaj.org/toc/1177-5483Hanefi Cakir1, Canan Asli Utine2, Mehmet Baykara31Turkiye Hospital Eye Clinic, Istanbul, 2Department of Ophthalmology, Yeditepe University, Istanbul, 3Department of Ophthalmology, Uludag University, Bursa, TurkeyPurpose: To report the use of intracorneal ring segment (ICRS) implantation in a case of severe corneal thinning and irregularity secondary to alkali burn.Case report: A 33-year-old man who had a history of ocular alkali burn in the right eye was admitted. His best corrected visual acuity was 0.16 with manifest refraction of +5.00 (-7.00 × 180°). Orbscan II® revealed steepening of >53 D superiorly, excessive thinning inferiorly with thinnest pachymetric reading of 269 µm. Two KeraRing® segments, 200 µm thick and 90° arced, were implanted. During intrastromal channel creation by Intralase®, the inferior half of the applanating cone was covered by a gelatinous paper to prevent the penetration of the laser beam into the anterior chamber. In the first year postoperation, best corrected visual acuity was 0.7 with manifest refraction of +1.50 (-3.50 × 35°). Visante® opticial coherence tomography displayed ICRS at a depth of ~370 µm.Conclusion: ICRS implantation with this novel approach may be an option in eyes with severe corneal irregularity and thinning.Keywords: alkali burn, ectasia, intrastromal corneal ring segmentsCakir HUtine CABaykara MDove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2011, Iss default, Pp 1631-1635 (2011)
institution DOAJ
collection DOAJ
language EN
topic Ophthalmology
RE1-994
spellingShingle Ophthalmology
RE1-994
Cakir H
Utine CA
Baykara M
Intracorneal ring implantation using Intralase® with partial coverage of the cone in a patient after an alkaline injury
description Hanefi Cakir1, Canan Asli Utine2, Mehmet Baykara31Turkiye Hospital Eye Clinic, Istanbul, 2Department of Ophthalmology, Yeditepe University, Istanbul, 3Department of Ophthalmology, Uludag University, Bursa, TurkeyPurpose: To report the use of intracorneal ring segment (ICRS) implantation in a case of severe corneal thinning and irregularity secondary to alkali burn.Case report: A 33-year-old man who had a history of ocular alkali burn in the right eye was admitted. His best corrected visual acuity was 0.16 with manifest refraction of +5.00 (-7.00 × 180°). Orbscan II® revealed steepening of >53 D superiorly, excessive thinning inferiorly with thinnest pachymetric reading of 269 µm. Two KeraRing® segments, 200 µm thick and 90° arced, were implanted. During intrastromal channel creation by Intralase®, the inferior half of the applanating cone was covered by a gelatinous paper to prevent the penetration of the laser beam into the anterior chamber. In the first year postoperation, best corrected visual acuity was 0.7 with manifest refraction of +1.50 (-3.50 × 35°). Visante® opticial coherence tomography displayed ICRS at a depth of ~370 µm.Conclusion: ICRS implantation with this novel approach may be an option in eyes with severe corneal irregularity and thinning.Keywords: alkali burn, ectasia, intrastromal corneal ring segments
format article
author Cakir H
Utine CA
Baykara M
author_facet Cakir H
Utine CA
Baykara M
author_sort Cakir H
title Intracorneal ring implantation using Intralase® with partial coverage of the cone in a patient after an alkaline injury
title_short Intracorneal ring implantation using Intralase® with partial coverage of the cone in a patient after an alkaline injury
title_full Intracorneal ring implantation using Intralase® with partial coverage of the cone in a patient after an alkaline injury
title_fullStr Intracorneal ring implantation using Intralase® with partial coverage of the cone in a patient after an alkaline injury
title_full_unstemmed Intracorneal ring implantation using Intralase® with partial coverage of the cone in a patient after an alkaline injury
title_sort intracorneal ring implantation using intralase® with partial coverage of the cone in a patient after an alkaline injury
publisher Dove Medical Press
publishDate 2011
url https://doaj.org/article/f747ef086e7945b0bf7e410ae5b60df3
work_keys_str_mv AT cakirh intracornealringimplantationusingintralaseampregwithpartialcoverageoftheconeinapatientafteranalkalineinjury
AT utineca intracornealringimplantationusingintralaseampregwithpartialcoverageoftheconeinapatientafteranalkalineinjury
AT baykaram intracornealringimplantationusingintralaseampregwithpartialcoverageoftheconeinapatientafteranalkalineinjury
_version_ 1718400029585047552