Expansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum discharger

Purpose. An experimental verification of the existence of a range of values for the parameters of the capacitive energy storage of the magnetic-pulse installations with controlled vacuum discharger, in which, with a high probability, there is a «cut» of the discharge current pulses and the expansion...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: L. A. Ljutenko, V. M. Mikhailov
Formato: article
Lenguaje:EN
RU
UK
Publicado: National Technical University "Kharkiv Polytechnic Institute" 2021
Materias:
Acceso en línea:https://doaj.org/article/f7a5277160fb4065b92474654a3248a1
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:f7a5277160fb4065b92474654a3248a1
record_format dspace
spelling oai:doaj.org-article:f7a5277160fb4065b92474654a3248a12021-12-02T18:42:30ZExpansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum discharger10.20998/2074-272X.2021.3.072074-272X2309-3404https://doaj.org/article/f7a5277160fb4065b92474654a3248a12021-06-01T00:00:00Zhttp://eie.khpi.edu.ua/article/view/234463/233444https://doaj.org/toc/2074-272Xhttps://doaj.org/toc/2309-3404Purpose. An experimental verification of the existence of a range of values for the parameters of the capacitive energy storage of the magnetic-pulse installations with controlled vacuum discharger, in which, with a high probability, there is a «cut» of the discharge current pulses and the expansion of cylindrical thin-walled tubular workpieces using an external coil. Methodology. High voltage magnetic-pulse installation of NTU «KhPI» with controlled vacuum discharger, multiturn coil with inside dielectrical die and inside aluminum alloy workpiece are used. The capacitance and charge voltage of capacitive energy storage are changed. Discharge current pulses are measured by Rogowski coil and the oscillograph. Results. Parts of complicated shape are made by expansion of cylindrical tubular workpieces with help of external coil. Pressed metallic tubular part is removable from inner dielectric rod. Originality. The frequency of «cut» pulse is defined by negative magnetic field pressure amplitude. It is shown that we must coordinate this frequency and charge voltage with capacitive storage parameters by high probability of pulse «cut». Practical value. It is shown how to use installations with controlled vacuum dischargers in magnetic forming technology based on «cut» pulses.L. A. LjutenkoV. M. MikhailovNational Technical University "Kharkiv Polytechnic Institute"articlehigh-voltage magnetic-pulse installationscapacitive energy storagecontrolled vacuum dischargercurrent pulse «cut»probability of «cut»external coilexpansion of cylindrical tubular workpiecepart of complicated shapeElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENRUUKElectrical engineering & Electromechanics, Iss 3, Pp 42-46 (2021)
institution DOAJ
collection DOAJ
language EN
RU
UK
topic high-voltage magnetic-pulse installations
capacitive energy storage
controlled vacuum discharger
current pulse «cut»
probability of «cut»
external coil
expansion of cylindrical tubular workpiece
part of complicated shape
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
spellingShingle high-voltage magnetic-pulse installations
capacitive energy storage
controlled vacuum discharger
current pulse «cut»
probability of «cut»
external coil
expansion of cylindrical tubular workpiece
part of complicated shape
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
L. A. Ljutenko
V. M. Mikhailov
Expansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum discharger
description Purpose. An experimental verification of the existence of a range of values for the parameters of the capacitive energy storage of the magnetic-pulse installations with controlled vacuum discharger, in which, with a high probability, there is a «cut» of the discharge current pulses and the expansion of cylindrical thin-walled tubular workpieces using an external coil. Methodology. High voltage magnetic-pulse installation of NTU «KhPI» with controlled vacuum discharger, multiturn coil with inside dielectrical die and inside aluminum alloy workpiece are used. The capacitance and charge voltage of capacitive energy storage are changed. Discharge current pulses are measured by Rogowski coil and the oscillograph. Results. Parts of complicated shape are made by expansion of cylindrical tubular workpieces with help of external coil. Pressed metallic tubular part is removable from inner dielectric rod. Originality. The frequency of «cut» pulse is defined by negative magnetic field pressure amplitude. It is shown that we must coordinate this frequency and charge voltage with capacitive storage parameters by high probability of pulse «cut». Practical value. It is shown how to use installations with controlled vacuum dischargers in magnetic forming technology based on «cut» pulses.
format article
author L. A. Ljutenko
V. M. Mikhailov
author_facet L. A. Ljutenko
V. M. Mikhailov
author_sort L. A. Ljutenko
title Expansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum discharger
title_short Expansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum discharger
title_full Expansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum discharger
title_fullStr Expansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum discharger
title_full_unstemmed Expansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum discharger
title_sort expansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum discharger
publisher National Technical University "Kharkiv Polytechnic Institute"
publishDate 2021
url https://doaj.org/article/f7a5277160fb4065b92474654a3248a1
work_keys_str_mv AT laljutenko expansionofcylindricaltubularworkpiecesonhighvoltagemagneticpulseinstallationwithcontrolledvacuumdischarger
AT vmmikhailov expansionofcylindricaltubularworkpiecesonhighvoltagemagneticpulseinstallationwithcontrolledvacuumdischarger
_version_ 1718377777317543936