Ocular iontophoresis of EGP-437 (dexamethasone phosphate) in dry eye patients: results of a randomized clinical trial

Michael A Patane¹, Amy Cohen¹, Stephen From¹, Gail Torkildsen², Donna Welch³, George W Ousler III³¹Eyegate Pharmaceuticals, Inc, Waltham, MA, USA; ²Andover Eye Associates, Andover, MA, USA; &a...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Patane MA, Cohen A, From S, Torkildsen G, Welch D, Ousler GW 3rd
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2011
Materias:
Acceso en línea:https://doaj.org/article/f7ea8f1efe324a0e9cafdfd284ab518d
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:Michael A Patane¹, Amy Cohen¹, Stephen From¹, Gail Torkildsen², Donna Welch³, George W Ousler III³¹Eyegate Pharmaceuticals, Inc, Waltham, MA, USA; ²Andover Eye Associates, Andover, MA, USA; ³Ora, Inc, Andover, MA, USAPurpose: To assess safety and efficacy of EGP-437 (dexamethasone phosphate 40 mg/mL [DP]) in dry eye patients.Methods: The study employed a prospective, single-center, double-masked design utilizing a Controlled Adverse Environment (CAE). Patients (n = 103) with confirmed signs and symptoms of dry eye syndrome were randomized into 1 of 3 iontophoresis treatment groups: 7.5 mA-min at 2.5 mA (DP 7.5, n = 41); 10.5 mA-min at 3.5 mA (DP 10.5, n = 37); or 10.5 mA-min at 3.5 mA (placebo, n = 25). Three CAE visits and 4 follow-up visits occurred over 3 weeks. Patients meeting enrollment criteria received iontophoresis in both eyes after the second CAE exposure (visit 3) and before the third CAE exposure (visit 5). Primary efficacy endpoints were corneal staining and ocular discomfort. Secondary endpoints included tear film break-up time, ocular protection index (OPI), and symptomatology.Results: The DP 7.5 and DP 10.5 treatment groups showed statistically significant improvements in signs and symptoms of dry eye at various time points; however, the primary endpoints were not achieved. The DP 7.5 treatment group exhibited statistically significant improvements in corneal staining (when comparing the differences between study entry and exit, 3 weeks, P = 0.039), OPI (immediately following the second treatment, P = 0.048) and ocular discomfort at follow-up visits (a week after the first treatment, P = 0.032; 24 hours after the second treatment, P = 0.0032). Treatment-emergent adverse events (AEs) were experienced by 87% of patients and were consistent across all treatment groups. Most AEs were mild and no severe AEs were observed.Conclusion: Ocular iontophoresis of EGP-437 demonstrated statistically and clinically significant improvements in signs and symptoms of dry eye syndrome within a CAE model.Keywords: iontophoresis, dry eye, Controlled Adverse Environment (CAE), ocular protection index (OPI)