Study on The Effect of Different Plenum Chamber Coefficients on Frosting of Air-cooler
The performance of the air-cooler in the refrigeration system plays a key role in improving the energy efficiency. Here, the plenum chamber coefficient was defined to study a possible way of enhancing the refrigeration system performance. In order to investigate the influence of the plenum chamber c...
Guardado en:
Autores principales: | , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN FR |
Publicado: |
EDP Sciences
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/f7f36af31edd4b04af2bf7e43348ab94 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:f7f36af31edd4b04af2bf7e43348ab94 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:f7f36af31edd4b04af2bf7e43348ab942021-11-12T11:44:34ZStudy on The Effect of Different Plenum Chamber Coefficients on Frosting of Air-cooler2267-124210.1051/e3sconf/202132104019https://doaj.org/article/f7f36af31edd4b04af2bf7e43348ab942021-01-01T00:00:00Zhttps://www.e3s-conferences.org/articles/e3sconf/pdf/2021/97/e3sconf_icchmt2021_04019.pdfhttps://doaj.org/toc/2267-1242The performance of the air-cooler in the refrigeration system plays a key role in improving the energy efficiency. Here, the plenum chamber coefficient was defined to study a possible way of enhancing the refrigeration system performance. In order to investigate the influence of the plenum chamber coefficient on the frosting and the cooling system of the chillers, three plenum chamber coefficients (0.74,0.97,1.2) were studied under high humidity. The temperature decreasing curve of the environmental chamber, the velocity distribution of the air cooler, and the frost accumulation under and on the air-cooler were analysed. The results show that the frost accumulation on the tube will increase with the increase of the plenum chamber coefficient and the frost accumulation on the fin will increase at first and then decrease with the increase of the plenum chamber coefficient. On the whole, in this study, frosting is the most obvious when the plenum chamber coefficient was 0.97Liu BinShi ShengqiangLiu YongshanBennacer RachidChen AiqiangTheodorakis Panagiotis E.EDP SciencesarticleEnvironmental sciencesGE1-350ENFRE3S Web of Conferences, Vol 321, p 04019 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN FR |
topic |
Environmental sciences GE1-350 |
spellingShingle |
Environmental sciences GE1-350 Liu Bin Shi Shengqiang Liu Yongshan Bennacer Rachid Chen Aiqiang Theodorakis Panagiotis E. Study on The Effect of Different Plenum Chamber Coefficients on Frosting of Air-cooler |
description |
The performance of the air-cooler in the refrigeration system plays a key role in improving the energy efficiency. Here, the plenum chamber coefficient was defined to study a possible way of enhancing the refrigeration system performance. In order to investigate the influence of the plenum chamber coefficient on the frosting and the cooling system of the chillers, three plenum chamber coefficients (0.74,0.97,1.2) were studied under high humidity. The temperature decreasing curve of the environmental chamber, the velocity distribution of the air cooler, and the frost accumulation under and on the air-cooler were analysed. The results show that the frost accumulation on the tube will increase with the increase of the plenum chamber coefficient and the frost accumulation on the fin will increase at first and then decrease with the increase of the plenum chamber coefficient. On the whole, in this study, frosting is the most obvious when the plenum chamber coefficient was 0.97 |
format |
article |
author |
Liu Bin Shi Shengqiang Liu Yongshan Bennacer Rachid Chen Aiqiang Theodorakis Panagiotis E. |
author_facet |
Liu Bin Shi Shengqiang Liu Yongshan Bennacer Rachid Chen Aiqiang Theodorakis Panagiotis E. |
author_sort |
Liu Bin |
title |
Study on The Effect of Different Plenum Chamber Coefficients on Frosting of Air-cooler |
title_short |
Study on The Effect of Different Plenum Chamber Coefficients on Frosting of Air-cooler |
title_full |
Study on The Effect of Different Plenum Chamber Coefficients on Frosting of Air-cooler |
title_fullStr |
Study on The Effect of Different Plenum Chamber Coefficients on Frosting of Air-cooler |
title_full_unstemmed |
Study on The Effect of Different Plenum Chamber Coefficients on Frosting of Air-cooler |
title_sort |
study on the effect of different plenum chamber coefficients on frosting of air-cooler |
publisher |
EDP Sciences |
publishDate |
2021 |
url |
https://doaj.org/article/f7f36af31edd4b04af2bf7e43348ab94 |
work_keys_str_mv |
AT liubin studyontheeffectofdifferentplenumchambercoefficientsonfrostingofaircooler AT shishengqiang studyontheeffectofdifferentplenumchambercoefficientsonfrostingofaircooler AT liuyongshan studyontheeffectofdifferentplenumchambercoefficientsonfrostingofaircooler AT bennacerrachid studyontheeffectofdifferentplenumchambercoefficientsonfrostingofaircooler AT chenaiqiang studyontheeffectofdifferentplenumchambercoefficientsonfrostingofaircooler AT theodorakispanagiotise studyontheeffectofdifferentplenumchambercoefficientsonfrostingofaircooler |
_version_ |
1718430593209860096 |