Microbubble formulation influences inflammatory response to focused ultrasound exposure in the brain

Abstract Focused ultrasound and microbubble (FUS + MB)-mediated blood–brain barrier (BBB) permeability enhancement can facilitate targeted brain-drug delivery. While controlling the magnitude of BBB permeability enhancement is necessary to limit tissue damage, little work has attempted to decouple t...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Dallan McMahon, Anne Lassus, Emmanuel Gaud, Victor Jeannot, Kullervo Hynynen
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2020
Materias:
R
Q
Acceso en línea:https://doaj.org/article/f7f76de0ddf844a688e9fa902c63d8e1
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:Abstract Focused ultrasound and microbubble (FUS + MB)-mediated blood–brain barrier (BBB) permeability enhancement can facilitate targeted brain-drug delivery. While controlling the magnitude of BBB permeability enhancement is necessary to limit tissue damage, little work has attempted to decouple these concepts. This work investigated the relationship between BBB permeability enhancement and the relative transcription of inflammatory mediators 4 h following sonication. Three microbubble formulations, Definity, BG8774, and MSB4, were compared, with the dose of each formulation normalized to gas volume. While changes in the transcription of key proinflammatory mediators, such as Il1b, Ccl2, and Tnf, were correlated to the magnitude of BBB permeability enhancement, these correlations were not independent of microbubble formulation; microbubble size distribution may play an important role, as linear regression analyses of BBB permeability magnitude versus differential gene expression for these proinflammatory mediators revealed significantly greater slopes for MSB4, a monodisperse microbubble with mean diameter of 4 μm, compared to Definity or BG8774, both polydisperse microbubbles with mean diameters below 2 μm. Additionally, the function of an acoustic feedback control algorithm, based on the detection threshold of ultraharmonic emissions, was assessed. While this control strategy was effective in limiting both wideband emissions and red blood cell extravasation, microbubble formulation was found to influence the magnitude of BBB leakage and correlations to acoustic emissions. This work demonstrates that while the initial magnitude of FUS + MB-mediated BBB permeability enhancement has a clear influence on the subsequent inflammatory responses, microbubble characteristics influence these relationships and must also be considered.