Successful Implantation of a Leadless Pacemaker in a Patient With a Tricuspid Clip

Leadless pacemakers have become an effective alternative to conventional transvenous pacemakers to prevent the risk of lead failure, pocket complications, and iatrogenic tricuspid regurgitation. The current transcatheter approach for tricuspid valve repair can limit the implantation of these devices...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Maria Terricabras, MD, Enes Elvin Gul, MD, Yaariv Khaykin, MD, FHRS
Formato: article
Lenguaje:EN
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://doaj.org/article/f80801eed1b24d90844a967a45d8fbc0
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:f80801eed1b24d90844a967a45d8fbc0
record_format dspace
spelling oai:doaj.org-article:f80801eed1b24d90844a967a45d8fbc02021-11-26T04:38:12ZSuccessful Implantation of a Leadless Pacemaker in a Patient With a Tricuspid Clip2589-790X10.1016/j.cjco.2021.05.014https://doaj.org/article/f80801eed1b24d90844a967a45d8fbc02021-10-01T00:00:00Zhttp://www.sciencedirect.com/science/article/pii/S2589790X21001475https://doaj.org/toc/2589-790XLeadless pacemakers have become an effective alternative to conventional transvenous pacemakers to prevent the risk of lead failure, pocket complications, and iatrogenic tricuspid regurgitation. The current transcatheter approach for tricuspid valve repair can limit the implantation of these devices, unless the procedure is performed with appropriate image guidance. We present the case of a patient with severe tricuspid regurgitation secondary to pacemaker lead impingement who, despite the implantation of a tricuspid clip, received a leadless pacemaker. The procedure was successfully guided by transthoracic echocardiography, an alternative to transesophageal or intracardiac echocardiography. Résumé: Les stimulateurs cardiaques sans électrodes sont devenus une solution de rechange efficace aux stimulateurs transveineux classiques pour prévenir le risque de défaillance des électrodes, les complications liées à la loge et la régurgitation tricuspidienne iatrogène. L'approche actuelle de réparation de la valve tricuspide par cathétérisme peut empêcher l'implantation de ces dispositifs, à moins que l'intervention ne soit réalisée avec un guidage par image approprié. Nous présentons le cas d'un patient ayant une régurgitation tricuspidienne grave consécutive à la compression des électrodes d'un stimulateur cardiaque qui, malgré l'implantation d'un clip tricuspide, a reçu un stimulateur cardiaque sans électrodes. L'intervention a été guidée avec succès au moyen d'une échocardiographie par voie transthoracique, une solution de rechange à l’échocardiographie transœsophagienne ou intracardiaque.Maria Terricabras, MDEnes Elvin Gul, MDYaariv Khaykin, MD, FHRSElsevierarticleDiseases of the circulatory (Cardiovascular) systemRC666-701ENCJC Open, Vol 3, Iss 10, Pp 1310-1312 (2021)
institution DOAJ
collection DOAJ
language EN
topic Diseases of the circulatory (Cardiovascular) system
RC666-701
spellingShingle Diseases of the circulatory (Cardiovascular) system
RC666-701
Maria Terricabras, MD
Enes Elvin Gul, MD
Yaariv Khaykin, MD, FHRS
Successful Implantation of a Leadless Pacemaker in a Patient With a Tricuspid Clip
description Leadless pacemakers have become an effective alternative to conventional transvenous pacemakers to prevent the risk of lead failure, pocket complications, and iatrogenic tricuspid regurgitation. The current transcatheter approach for tricuspid valve repair can limit the implantation of these devices, unless the procedure is performed with appropriate image guidance. We present the case of a patient with severe tricuspid regurgitation secondary to pacemaker lead impingement who, despite the implantation of a tricuspid clip, received a leadless pacemaker. The procedure was successfully guided by transthoracic echocardiography, an alternative to transesophageal or intracardiac echocardiography. Résumé: Les stimulateurs cardiaques sans électrodes sont devenus une solution de rechange efficace aux stimulateurs transveineux classiques pour prévenir le risque de défaillance des électrodes, les complications liées à la loge et la régurgitation tricuspidienne iatrogène. L'approche actuelle de réparation de la valve tricuspide par cathétérisme peut empêcher l'implantation de ces dispositifs, à moins que l'intervention ne soit réalisée avec un guidage par image approprié. Nous présentons le cas d'un patient ayant une régurgitation tricuspidienne grave consécutive à la compression des électrodes d'un stimulateur cardiaque qui, malgré l'implantation d'un clip tricuspide, a reçu un stimulateur cardiaque sans électrodes. L'intervention a été guidée avec succès au moyen d'une échocardiographie par voie transthoracique, une solution de rechange à l’échocardiographie transœsophagienne ou intracardiaque.
format article
author Maria Terricabras, MD
Enes Elvin Gul, MD
Yaariv Khaykin, MD, FHRS
author_facet Maria Terricabras, MD
Enes Elvin Gul, MD
Yaariv Khaykin, MD, FHRS
author_sort Maria Terricabras, MD
title Successful Implantation of a Leadless Pacemaker in a Patient With a Tricuspid Clip
title_short Successful Implantation of a Leadless Pacemaker in a Patient With a Tricuspid Clip
title_full Successful Implantation of a Leadless Pacemaker in a Patient With a Tricuspid Clip
title_fullStr Successful Implantation of a Leadless Pacemaker in a Patient With a Tricuspid Clip
title_full_unstemmed Successful Implantation of a Leadless Pacemaker in a Patient With a Tricuspid Clip
title_sort successful implantation of a leadless pacemaker in a patient with a tricuspid clip
publisher Elsevier
publishDate 2021
url https://doaj.org/article/f80801eed1b24d90844a967a45d8fbc0
work_keys_str_mv AT mariaterricabrasmd successfulimplantationofaleadlesspacemakerinapatientwithatricuspidclip
AT eneselvingulmd successfulimplantationofaleadlesspacemakerinapatientwithatricuspidclip
AT yaarivkhaykinmdfhrs successfulimplantationofaleadlesspacemakerinapatientwithatricuspidclip
_version_ 1718409878670671872