Fully automated whole-liver volume quantification on CT-image data: Comparison with manual volumetry using enhanced and unenhanced images as well as two different radiation dose levels and two reconstruction kernels.

<h4>Objectives</h4>To evaluate the accuracy of fully automated liver volume quantification vs. manual quantification using unenhanced as well as enhanced CT-image data as well as two different radiation dose levels and also two image reconstruction kernels.<h4>Material and methods&...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Florian Hagen, Antonia Mair, Michael Bitzer, Hans Bösmüller, Marius Horger
Formato: article
Lenguaje:EN
Publicado: Public Library of Science (PLoS) 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/f8789ffef5a14c79a42bb421986d8301
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:f8789ffef5a14c79a42bb421986d8301
record_format dspace
spelling oai:doaj.org-article:f8789ffef5a14c79a42bb421986d83012021-12-02T20:18:50ZFully automated whole-liver volume quantification on CT-image data: Comparison with manual volumetry using enhanced and unenhanced images as well as two different radiation dose levels and two reconstruction kernels.1932-620310.1371/journal.pone.0255374https://doaj.org/article/f8789ffef5a14c79a42bb421986d83012021-01-01T00:00:00Zhttps://doi.org/10.1371/journal.pone.0255374https://doaj.org/toc/1932-6203<h4>Objectives</h4>To evaluate the accuracy of fully automated liver volume quantification vs. manual quantification using unenhanced as well as enhanced CT-image data as well as two different radiation dose levels and also two image reconstruction kernels.<h4>Material and methods</h4>The local ethics board gave its approval for retrospective data analysis. Automated liver volume quantification in 300 consecutive livers in 164 male and 103 female oncologic patients (64±12y) performed at our institution (between January 2020 and May 2020) using two different dual-energy helicals: portal-venous phase enhanced, ref. tube current 300mAs (CARE Dose4D) for tube A (100 kV) and ref. 232mAs tube current for tube B (Sn140kV), slice collimation 0.6mm, reconstruction kernel I30f/1, recon. thickness of 0.6mm and 5mm, 80-100 mL iodine contrast agent 350 mg/mL, (flow 2mL/s) and unenhanced ref. tube current 100mAs (CARE Dose4D) for tube A (100 kV) and ref. 77mAs tube current for tube B (Sn140kV), slice collimation 0.6mm (kernel Q40f) were analyzed. The post-processing tool (syngo.CT Liver Analysis) is already FDA-approved. Two resident radiologists with no and 1-year CT-experience performed both the automated measurements independently from each other. Results were compared with those of manual liver volume quantification using the same software which was supervised by a senior radiologist with 30-year CT-experience (ground truth).<h4>Results</h4>In total, a correlation of 98% was obtained for liver volumetry based on enhanced and unenhanced data sets compared to the manual liver quantification. Radiologist #1 and #2 achieved an inter-reader agreement of 99.8% for manual liver segmentation (p<0.0001). Automated liver volumetry resulted in an overestimation (>5% deviation) of 3.7% for unenhanced CT-image data and 4.0% for contrast-enhanced CT-images. Underestimation (<5%) of liver volume was 2.0% for unenhanced CT-image data and 1.3% for enhanced images after automated liver volumetry. Number and distribution of erroneous volume measurements using either thin or thick slice reconstructions was exactly the same, both for the enhanced as well for the unenhanced image data sets (p> 0.05).<h4>Conclusion</h4>Results of fully automated liver volume quantification are accurate and comparable with those of manual liver volume quantification and the technique seems to be confident even if unenhanced lower-dose CT image data is used.Florian HagenAntonia MairMichael BitzerHans BösmüllerMarius HorgerPublic Library of Science (PLoS)articleMedicineRScienceQENPLoS ONE, Vol 16, Iss 8, p e0255374 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Florian Hagen
Antonia Mair
Michael Bitzer
Hans Bösmüller
Marius Horger
Fully automated whole-liver volume quantification on CT-image data: Comparison with manual volumetry using enhanced and unenhanced images as well as two different radiation dose levels and two reconstruction kernels.
description <h4>Objectives</h4>To evaluate the accuracy of fully automated liver volume quantification vs. manual quantification using unenhanced as well as enhanced CT-image data as well as two different radiation dose levels and also two image reconstruction kernels.<h4>Material and methods</h4>The local ethics board gave its approval for retrospective data analysis. Automated liver volume quantification in 300 consecutive livers in 164 male and 103 female oncologic patients (64±12y) performed at our institution (between January 2020 and May 2020) using two different dual-energy helicals: portal-venous phase enhanced, ref. tube current 300mAs (CARE Dose4D) for tube A (100 kV) and ref. 232mAs tube current for tube B (Sn140kV), slice collimation 0.6mm, reconstruction kernel I30f/1, recon. thickness of 0.6mm and 5mm, 80-100 mL iodine contrast agent 350 mg/mL, (flow 2mL/s) and unenhanced ref. tube current 100mAs (CARE Dose4D) for tube A (100 kV) and ref. 77mAs tube current for tube B (Sn140kV), slice collimation 0.6mm (kernel Q40f) were analyzed. The post-processing tool (syngo.CT Liver Analysis) is already FDA-approved. Two resident radiologists with no and 1-year CT-experience performed both the automated measurements independently from each other. Results were compared with those of manual liver volume quantification using the same software which was supervised by a senior radiologist with 30-year CT-experience (ground truth).<h4>Results</h4>In total, a correlation of 98% was obtained for liver volumetry based on enhanced and unenhanced data sets compared to the manual liver quantification. Radiologist #1 and #2 achieved an inter-reader agreement of 99.8% for manual liver segmentation (p<0.0001). Automated liver volumetry resulted in an overestimation (>5% deviation) of 3.7% for unenhanced CT-image data and 4.0% for contrast-enhanced CT-images. Underestimation (<5%) of liver volume was 2.0% for unenhanced CT-image data and 1.3% for enhanced images after automated liver volumetry. Number and distribution of erroneous volume measurements using either thin or thick slice reconstructions was exactly the same, both for the enhanced as well for the unenhanced image data sets (p> 0.05).<h4>Conclusion</h4>Results of fully automated liver volume quantification are accurate and comparable with those of manual liver volume quantification and the technique seems to be confident even if unenhanced lower-dose CT image data is used.
format article
author Florian Hagen
Antonia Mair
Michael Bitzer
Hans Bösmüller
Marius Horger
author_facet Florian Hagen
Antonia Mair
Michael Bitzer
Hans Bösmüller
Marius Horger
author_sort Florian Hagen
title Fully automated whole-liver volume quantification on CT-image data: Comparison with manual volumetry using enhanced and unenhanced images as well as two different radiation dose levels and two reconstruction kernels.
title_short Fully automated whole-liver volume quantification on CT-image data: Comparison with manual volumetry using enhanced and unenhanced images as well as two different radiation dose levels and two reconstruction kernels.
title_full Fully automated whole-liver volume quantification on CT-image data: Comparison with manual volumetry using enhanced and unenhanced images as well as two different radiation dose levels and two reconstruction kernels.
title_fullStr Fully automated whole-liver volume quantification on CT-image data: Comparison with manual volumetry using enhanced and unenhanced images as well as two different radiation dose levels and two reconstruction kernels.
title_full_unstemmed Fully automated whole-liver volume quantification on CT-image data: Comparison with manual volumetry using enhanced and unenhanced images as well as two different radiation dose levels and two reconstruction kernels.
title_sort fully automated whole-liver volume quantification on ct-image data: comparison with manual volumetry using enhanced and unenhanced images as well as two different radiation dose levels and two reconstruction kernels.
publisher Public Library of Science (PLoS)
publishDate 2021
url https://doaj.org/article/f8789ffef5a14c79a42bb421986d8301
work_keys_str_mv AT florianhagen fullyautomatedwholelivervolumequantificationonctimagedatacomparisonwithmanualvolumetryusingenhancedandunenhancedimagesaswellastwodifferentradiationdoselevelsandtworeconstructionkernels
AT antoniamair fullyautomatedwholelivervolumequantificationonctimagedatacomparisonwithmanualvolumetryusingenhancedandunenhancedimagesaswellastwodifferentradiationdoselevelsandtworeconstructionkernels
AT michaelbitzer fullyautomatedwholelivervolumequantificationonctimagedatacomparisonwithmanualvolumetryusingenhancedandunenhancedimagesaswellastwodifferentradiationdoselevelsandtworeconstructionkernels
AT hansbosmuller fullyautomatedwholelivervolumequantificationonctimagedatacomparisonwithmanualvolumetryusingenhancedandunenhancedimagesaswellastwodifferentradiationdoselevelsandtworeconstructionkernels
AT mariushorger fullyautomatedwholelivervolumequantificationonctimagedatacomparisonwithmanualvolumetryusingenhancedandunenhancedimagesaswellastwodifferentradiationdoselevelsandtworeconstructionkernels
_version_ 1718374262196142080