Angiography‐guided mid/high septal implantation of ventricular leads in patients with congenital heart disease

Abstract Background Conduction system pacing prevents pacing‐induced cardiomyopathy, but it can be challenging to perform in patients with congenital heart disease (CHD), and mid/high septal lead implantation is an alternative. This study aimed to assess intraprocedural angiography's utility as...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Jayaprakash Shenthar, Sanjai P. Valappil, Maneesh K. Rai, Bharatraj Banavalikar, Deepak Padmanabhan, Tammo Delhaas
Formato: article
Lenguaje:EN
Publicado: Wiley 2021
Materias:
Acceso en línea:https://doaj.org/article/f8d1a797f8964e7bb4f2e67a3033aac7
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:Abstract Background Conduction system pacing prevents pacing‐induced cardiomyopathy, but it can be challenging to perform in patients with congenital heart disease (CHD), and mid/high septal lead implantation is an alternative. This study aimed to assess intraprocedural angiography's utility as a guide for mid/high‐septal lead implantation in CHD patients. Methods The study subjects were CHD patients with Class I/IIa indications for permanent pacemaker implantation. To guide septal lead implantation, we performed an intraprocedural right ventricular angiogram in anteroposterior, 40° left anterior oblique, and 30° right anterior oblique. The primary endpoint was the lead tip in the mid/high septum on computed tomography (CT). The secondary endpoints were complications and systemic ventricular function on follow‐up. Results From January 2008 to December 2018, we enrolled 27 patients (mean age: 30 ± 20 years; M:F 17:10) with CHD (unoperated: 20, operated: 7). The mean paced QRS duration was 131.7 ± 5.8 ms, and CT done in 22/27 patients confirmed the lead tip in the mid‐septum in 16, high septum in 5, and apical septum in 1 patient. There were no procedural complications, and during a mean follow‐up of 58 ± 35.2 months, there was no significant change in the systemic ventricular ejection fraction (56.4 ± 8.3% vs 53.9 + 5.9%, P = .08). Two patients with Eisenmenger syndrome died because of refractory heart failure. Conclusions Intraprocedural angiography is safe and useful to guide mid/high‐septal lead implantation in CHD patients. Mid/high septal lead position preserves systemic ventricular function in patients with CHD during medium‐term follow‐up.