Sigma metrics of Alinity ci system – a study on thirty-nine clinical chemistry and immunoassay parameters
Sigma metrics in an invaluable and inexpensive tool used in laboratories to monitor analytical quality of the assays. Alinity ci platform is a relatively recent analytical system launched by Abbott Diagnostics, and as such performance studies on it are few. We have calculated sigma metrics of 39 cli...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | EN ES |
Publicado: |
De Gruyter
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/f9eb6a403d3748778b36dc2212b3144a |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:f9eb6a403d3748778b36dc2212b3144a |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:f9eb6a403d3748778b36dc2212b3144a2021-12-05T14:10:39ZSigma metrics of Alinity ci system – a study on thirty-nine clinical chemistry and immunoassay parameters2628-491X10.1515/almed-2021-0001https://doaj.org/article/f9eb6a403d3748778b36dc2212b3144a2021-04-01T00:00:00Zhttps://doi.org/10.1515/almed-2021-0001https://doaj.org/toc/2628-491XSigma metrics in an invaluable and inexpensive tool used in laboratories to monitor analytical quality of the assays. Alinity ci platform is a relatively recent analytical system launched by Abbott Diagnostics, and as such performance studies on it are few. We have calculated sigma metrics of 39 clinical chemistry and immunoassay analytes on two Alinity ci systems.Kanani Fatima ZehraHaider Kazmi AdnanKaleem BushraDe Gruyterarticleaccuracyperformance specificationsprecisionsix sigmavalidationMedical technologyR855-855.5ENESAdvances in Laboratory Medicine, Vol 2, Iss 2, Pp 267-275 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN ES |
topic |
accuracy performance specifications precision six sigma validation Medical technology R855-855.5 |
spellingShingle |
accuracy performance specifications precision six sigma validation Medical technology R855-855.5 Kanani Fatima Zehra Haider Kazmi Adnan Kaleem Bushra Sigma metrics of Alinity ci system – a study on thirty-nine clinical chemistry and immunoassay parameters |
description |
Sigma metrics in an invaluable and inexpensive tool used in laboratories to monitor analytical quality of the assays. Alinity ci platform is a relatively recent analytical system launched by Abbott Diagnostics, and as such performance studies on it are few. We have calculated sigma metrics of 39 clinical chemistry and immunoassay analytes on two Alinity ci systems. |
format |
article |
author |
Kanani Fatima Zehra Haider Kazmi Adnan Kaleem Bushra |
author_facet |
Kanani Fatima Zehra Haider Kazmi Adnan Kaleem Bushra |
author_sort |
Kanani Fatima Zehra |
title |
Sigma metrics of Alinity ci system – a study on thirty-nine clinical chemistry and immunoassay parameters |
title_short |
Sigma metrics of Alinity ci system – a study on thirty-nine clinical chemistry and immunoassay parameters |
title_full |
Sigma metrics of Alinity ci system – a study on thirty-nine clinical chemistry and immunoassay parameters |
title_fullStr |
Sigma metrics of Alinity ci system – a study on thirty-nine clinical chemistry and immunoassay parameters |
title_full_unstemmed |
Sigma metrics of Alinity ci system – a study on thirty-nine clinical chemistry and immunoassay parameters |
title_sort |
sigma metrics of alinity ci system – a study on thirty-nine clinical chemistry and immunoassay parameters |
publisher |
De Gruyter |
publishDate |
2021 |
url |
https://doaj.org/article/f9eb6a403d3748778b36dc2212b3144a |
work_keys_str_mv |
AT kananifatimazehra sigmametricsofalinitycisystemastudyonthirtynineclinicalchemistryandimmunoassayparameters AT haiderkazmiadnan sigmametricsofalinitycisystemastudyonthirtynineclinicalchemistryandimmunoassayparameters AT kaleembushra sigmametricsofalinitycisystemastudyonthirtynineclinicalchemistryandimmunoassayparameters |
_version_ |
1718371875906650112 |