Natural Convection in Trapezoidal Enclosure Heated Partially from Below
Natural convection in a trapezoidal enclosure with partial heating from below and symmetrical cooling from the sides has been investigated numerically. The heating is simulated by a centrally located heat source on the bottom wall, and four different values of the dimensionless heat source length,...
Guardado en:
Autores principales: | , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Al-Khwarizmi College of Engineering – University of Baghdad
2012
|
Materias: | |
Acceso en línea: | https://doaj.org/article/fb57d0d41fc44a988e3020588aa22438 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:fb57d0d41fc44a988e3020588aa22438 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:fb57d0d41fc44a988e3020588aa224382021-12-02T10:53:35ZNatural Convection in Trapezoidal Enclosure Heated Partially from Below1818-11712312-0789https://doaj.org/article/fb57d0d41fc44a988e3020588aa224382012-02-01T00:00:00Zhttp://alkej.uobaghdad.edu.iq/index.php/alkej/article/view/107https://doaj.org/toc/1818-1171https://doaj.org/toc/2312-0789 Natural convection in a trapezoidal enclosure with partial heating from below and symmetrical cooling from the sides has been investigated numerically. The heating is simulated by a centrally located heat source on the bottom wall, and four different values of the dimensionless heat source length, 1/5, 2/5, 3/5, 4/5 are considered. The laminar flow field is analyzed numerically by solving the steady, two-dimensional incompressible Navier-Stokes and energy equations. The Cartesian velocity components and pressure on a collocated (non-staggered) grid are used as dependent variables in the momentum equations discretized by finite volume method; body fitted coordinates are used to represent the trapezoidal enclosure, and grid generation technique based on elliptic partial differential equations is employed. SIMPLE algorithm is used to adjust the velocity field to satisfy the conservation of mass. The range of Rayleigh number is (103≤ Ra ≤105) and Prandtl number is 0.7. The results show that the average Nusselt number increases with the increases of the source length. Ahmed W. MustafaIhsan Ali GhaniAl-Khwarizmi College of Engineering – University of BaghdadarticleNatural ConvectionTrapezoidal EnclosureFinite VolumeChemical engineeringTP155-156Engineering (General). Civil engineering (General)TA1-2040ENAl-Khawarizmi Engineering Journal, Vol 8, Iss 1 (2012) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Natural Convection Trapezoidal Enclosure Finite Volume Chemical engineering TP155-156 Engineering (General). Civil engineering (General) TA1-2040 |
spellingShingle |
Natural Convection Trapezoidal Enclosure Finite Volume Chemical engineering TP155-156 Engineering (General). Civil engineering (General) TA1-2040 Ahmed W. Mustafa Ihsan Ali Ghani Natural Convection in Trapezoidal Enclosure Heated Partially from Below |
description |
Natural convection in a trapezoidal enclosure with partial heating from below and symmetrical cooling from the sides has been investigated numerically. The heating is simulated by a centrally located heat source on the bottom wall, and four different values of the dimensionless heat source length, 1/5, 2/5, 3/5, 4/5 are considered. The laminar flow field is analyzed numerically by solving the steady, two-dimensional incompressible Navier-Stokes and energy equations. The Cartesian velocity components and pressure on a collocated (non-staggered) grid are used as dependent variables in the momentum equations discretized by finite volume method; body fitted coordinates are used to represent the trapezoidal enclosure, and grid generation technique based on elliptic partial differential equations is employed. SIMPLE algorithm is used to adjust the velocity field to satisfy the conservation of mass. The range of Rayleigh number is (103≤ Ra ≤105) and Prandtl number is 0.7. The results show that the average Nusselt number increases with the increases of the source length.
|
format |
article |
author |
Ahmed W. Mustafa Ihsan Ali Ghani |
author_facet |
Ahmed W. Mustafa Ihsan Ali Ghani |
author_sort |
Ahmed W. Mustafa |
title |
Natural Convection in Trapezoidal Enclosure Heated Partially from Below |
title_short |
Natural Convection in Trapezoidal Enclosure Heated Partially from Below |
title_full |
Natural Convection in Trapezoidal Enclosure Heated Partially from Below |
title_fullStr |
Natural Convection in Trapezoidal Enclosure Heated Partially from Below |
title_full_unstemmed |
Natural Convection in Trapezoidal Enclosure Heated Partially from Below |
title_sort |
natural convection in trapezoidal enclosure heated partially from below |
publisher |
Al-Khwarizmi College of Engineering – University of Baghdad |
publishDate |
2012 |
url |
https://doaj.org/article/fb57d0d41fc44a988e3020588aa22438 |
work_keys_str_mv |
AT ahmedwmustafa naturalconvectionintrapezoidalenclosureheatedpartiallyfrombelow AT ihsanalighani naturalconvectionintrapezoidalenclosureheatedpartiallyfrombelow |
_version_ |
1718396507866005504 |