Experimental Validation of a Method of Drying Cellulose Insulation in Distribution Transformers Using Circulating Synthetic Ester
The article concerns a method of drying cellulose insulation of distribution transformers with the use of synthetic ester. This method uses the high solubility of water in the ester compared to other dielectric liquids. The method is based on the striving of the oil-paper insulation system for a sta...
Guardado en:
Autores principales: | , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
IEEE
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/fb779f5d8b834bc2a3ed7e3061943a71 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:fb779f5d8b834bc2a3ed7e3061943a71 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:fb779f5d8b834bc2a3ed7e3061943a712021-11-18T00:08:59ZExperimental Validation of a Method of Drying Cellulose Insulation in Distribution Transformers Using Circulating Synthetic Ester2169-353610.1109/ACCESS.2021.3125840https://doaj.org/article/fb779f5d8b834bc2a3ed7e3061943a712021-01-01T00:00:00Zhttps://ieeexplore.ieee.org/document/9605584/https://doaj.org/toc/2169-3536The article concerns a method of drying cellulose insulation of distribution transformers with the use of synthetic ester. This method uses the high solubility of water in the ester compared to other dielectric liquids. The method is based on the striving of the oil-paper insulation system for a state of moisture equilibrium. Water migrates from the cellulose insulation of the high moisture content to the synthetic ester which is subjected to continuous drying. The research was carried out on a complex laboratory model reflecting the transformer insulation system. In this model, the drying of the ester was carried out using a molecular sieve with an appropriately selected adsorber weight. To check the drying efficiency of the cellulose insulation, the water content in the pressboard strips taken from the model, both before and after the drying process, was determined. The water content was measured using the Karl Fischer titration method. The research showed the high efficiency of the proposed method of drying. With the ester moisture in the range of 110-130 ppm and the insulation system temperature of about 70 °C, the loss of water in the samples dried for 7 days was over one percentage point. The obtained test results constitute the basis for the validation of the method on distribution transformers.Piotr PrzybylekKrzysztof WalczakWojciech SikorskiHanna Moscicka-GrzesiakHubert MorandaMateusz CybulskiIEEEarticlePower transformersinsulationmoisturedielectric liquidsElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENIEEE Access, Vol 9, Pp 150322-150329 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Power transformers insulation moisture dielectric liquids Electrical engineering. Electronics. Nuclear engineering TK1-9971 |
spellingShingle |
Power transformers insulation moisture dielectric liquids Electrical engineering. Electronics. Nuclear engineering TK1-9971 Piotr Przybylek Krzysztof Walczak Wojciech Sikorski Hanna Moscicka-Grzesiak Hubert Moranda Mateusz Cybulski Experimental Validation of a Method of Drying Cellulose Insulation in Distribution Transformers Using Circulating Synthetic Ester |
description |
The article concerns a method of drying cellulose insulation of distribution transformers with the use of synthetic ester. This method uses the high solubility of water in the ester compared to other dielectric liquids. The method is based on the striving of the oil-paper insulation system for a state of moisture equilibrium. Water migrates from the cellulose insulation of the high moisture content to the synthetic ester which is subjected to continuous drying. The research was carried out on a complex laboratory model reflecting the transformer insulation system. In this model, the drying of the ester was carried out using a molecular sieve with an appropriately selected adsorber weight. To check the drying efficiency of the cellulose insulation, the water content in the pressboard strips taken from the model, both before and after the drying process, was determined. The water content was measured using the Karl Fischer titration method. The research showed the high efficiency of the proposed method of drying. With the ester moisture in the range of 110-130 ppm and the insulation system temperature of about 70 °C, the loss of water in the samples dried for 7 days was over one percentage point. The obtained test results constitute the basis for the validation of the method on distribution transformers. |
format |
article |
author |
Piotr Przybylek Krzysztof Walczak Wojciech Sikorski Hanna Moscicka-Grzesiak Hubert Moranda Mateusz Cybulski |
author_facet |
Piotr Przybylek Krzysztof Walczak Wojciech Sikorski Hanna Moscicka-Grzesiak Hubert Moranda Mateusz Cybulski |
author_sort |
Piotr Przybylek |
title |
Experimental Validation of a Method of Drying Cellulose Insulation in Distribution Transformers Using Circulating Synthetic Ester |
title_short |
Experimental Validation of a Method of Drying Cellulose Insulation in Distribution Transformers Using Circulating Synthetic Ester |
title_full |
Experimental Validation of a Method of Drying Cellulose Insulation in Distribution Transformers Using Circulating Synthetic Ester |
title_fullStr |
Experimental Validation of a Method of Drying Cellulose Insulation in Distribution Transformers Using Circulating Synthetic Ester |
title_full_unstemmed |
Experimental Validation of a Method of Drying Cellulose Insulation in Distribution Transformers Using Circulating Synthetic Ester |
title_sort |
experimental validation of a method of drying cellulose insulation in distribution transformers using circulating synthetic ester |
publisher |
IEEE |
publishDate |
2021 |
url |
https://doaj.org/article/fb779f5d8b834bc2a3ed7e3061943a71 |
work_keys_str_mv |
AT piotrprzybylek experimentalvalidationofamethodofdryingcelluloseinsulationindistributiontransformersusingcirculatingsyntheticester AT krzysztofwalczak experimentalvalidationofamethodofdryingcelluloseinsulationindistributiontransformersusingcirculatingsyntheticester AT wojciechsikorski experimentalvalidationofamethodofdryingcelluloseinsulationindistributiontransformersusingcirculatingsyntheticester AT hannamoscickagrzesiak experimentalvalidationofamethodofdryingcelluloseinsulationindistributiontransformersusingcirculatingsyntheticester AT hubertmoranda experimentalvalidationofamethodofdryingcelluloseinsulationindistributiontransformersusingcirculatingsyntheticester AT mateuszcybulski experimentalvalidationofamethodofdryingcelluloseinsulationindistributiontransformersusingcirculatingsyntheticester |
_version_ |
1718425263437512704 |