Experimental study on lateral displacement measurement using air-coupled ultrasound transducers

We propose a novel measurement method for directly measuring the lateral displacement of structures by using air-coupled ultrasound transducers. The normally-distributed far field of an ultrasound transducer in a lateral direction is taken advantage of for the purposes of measuring lateral displacem...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Iwao MATSUYA, Fumiya MATSUMOTO, Ikuo IHARA
Formato: article
Lenguaje:EN
Publicado: The Japan Society of Mechanical Engineers 2014
Materias:
Acceso en línea:https://doaj.org/article/fc213c0f55be492da4aa3804da5c7bd0
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:fc213c0f55be492da4aa3804da5c7bd0
record_format dspace
spelling oai:doaj.org-article:fc213c0f55be492da4aa3804da5c7bd02021-11-26T06:16:58ZExperimental study on lateral displacement measurement using air-coupled ultrasound transducers2187-974510.1299/mej.14-00379https://doaj.org/article/fc213c0f55be492da4aa3804da5c7bd02014-12-01T00:00:00Zhttps://www.jstage.jst.go.jp/article/mej/2/1/2_14-00379/_pdf/-char/enhttps://doaj.org/toc/2187-9745We propose a novel measurement method for directly measuring the lateral displacement of structures by using air-coupled ultrasound transducers. The normally-distributed far field of an ultrasound transducer in a lateral direction is taken advantage of for the purposes of measuring lateral displacement. The measurement system is composed of three flat-type air-coupled ultrasound transducers and a steel wire as a target. The ultrasound transducers are immobilized at a fixed point, whereas the steel wire is separately arranged on the opposite side. When the steel wire is displaced laterally, the lateral displacement is calculated utilizing the intensity ratio of the reflected ultrasound waves. The accuracy of the lateral displacement measurement is experimentally assessed to be within ± 0.5 mm and the feasibility of the measurement system is discussed. The results show that a developed displacement measurement method will be usable in the field of structural health monitoring due to its accuracy and wide measurement range through the use of several ultrasound transducers.Iwao MATSUYAFumiya MATSUMOTOIkuo IHARAThe Japan Society of Mechanical Engineersarticlelateral displacementair-coupled ultrasoundearthquakebuilding structuredamage assessmentstructural health monitoringMechanical engineering and machineryTJ1-1570ENMechanical Engineering Journal, Vol 2, Iss 1, Pp 14-00379-14-00379 (2014)
institution DOAJ
collection DOAJ
language EN
topic lateral displacement
air-coupled ultrasound
earthquake
building structure
damage assessment
structural health monitoring
Mechanical engineering and machinery
TJ1-1570
spellingShingle lateral displacement
air-coupled ultrasound
earthquake
building structure
damage assessment
structural health monitoring
Mechanical engineering and machinery
TJ1-1570
Iwao MATSUYA
Fumiya MATSUMOTO
Ikuo IHARA
Experimental study on lateral displacement measurement using air-coupled ultrasound transducers
description We propose a novel measurement method for directly measuring the lateral displacement of structures by using air-coupled ultrasound transducers. The normally-distributed far field of an ultrasound transducer in a lateral direction is taken advantage of for the purposes of measuring lateral displacement. The measurement system is composed of three flat-type air-coupled ultrasound transducers and a steel wire as a target. The ultrasound transducers are immobilized at a fixed point, whereas the steel wire is separately arranged on the opposite side. When the steel wire is displaced laterally, the lateral displacement is calculated utilizing the intensity ratio of the reflected ultrasound waves. The accuracy of the lateral displacement measurement is experimentally assessed to be within ± 0.5 mm and the feasibility of the measurement system is discussed. The results show that a developed displacement measurement method will be usable in the field of structural health monitoring due to its accuracy and wide measurement range through the use of several ultrasound transducers.
format article
author Iwao MATSUYA
Fumiya MATSUMOTO
Ikuo IHARA
author_facet Iwao MATSUYA
Fumiya MATSUMOTO
Ikuo IHARA
author_sort Iwao MATSUYA
title Experimental study on lateral displacement measurement using air-coupled ultrasound transducers
title_short Experimental study on lateral displacement measurement using air-coupled ultrasound transducers
title_full Experimental study on lateral displacement measurement using air-coupled ultrasound transducers
title_fullStr Experimental study on lateral displacement measurement using air-coupled ultrasound transducers
title_full_unstemmed Experimental study on lateral displacement measurement using air-coupled ultrasound transducers
title_sort experimental study on lateral displacement measurement using air-coupled ultrasound transducers
publisher The Japan Society of Mechanical Engineers
publishDate 2014
url https://doaj.org/article/fc213c0f55be492da4aa3804da5c7bd0
work_keys_str_mv AT iwaomatsuya experimentalstudyonlateraldisplacementmeasurementusingaircoupledultrasoundtransducers
AT fumiyamatsumoto experimentalstudyonlateraldisplacementmeasurementusingaircoupledultrasoundtransducers
AT ikuoihara experimentalstudyonlateraldisplacementmeasurementusingaircoupledultrasoundtransducers
_version_ 1718409819714486272