Visual Acuity, Defocus Curve, Reading Speed and Patient Satisfaction with a Combined Extended Depth of Focus Intraocular Lens and Multifocal Intraocular Lens Modality

Helga P Sandoval,1 Richard Potvin,2 Kerry D Solomon1 1Carolina Eyecare Physicians, LLC, Mt. Pleasant, SC, USA; 2Science in Vision, Bend, OR, USACorrespondence: Kerry D SolomonCarolina Eyecare Physicians, LLC, 1101 Clarity Road, Suite 100, Mt Pleasant, SC 29464, USAEmail kerry.solomon@carolinaeyecare...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Sandoval HP, Potvin R, Solomon KD
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2020
Materias:
Acceso en línea:https://doaj.org/article/fc6a7f9898cc4970b618e219bd547fd9
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:fc6a7f9898cc4970b618e219bd547fd9
record_format dspace
spelling oai:doaj.org-article:fc6a7f9898cc4970b618e219bd547fd92021-12-02T15:41:47ZVisual Acuity, Defocus Curve, Reading Speed and Patient Satisfaction with a Combined Extended Depth of Focus Intraocular Lens and Multifocal Intraocular Lens Modality1177-5483https://doaj.org/article/fc6a7f9898cc4970b618e219bd547fd92020-09-01T00:00:00Zhttps://www.dovepress.com/visual-acuity-defocus-curve-reading-speed-and-patient-satisfaction-wit-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Helga P Sandoval,1 Richard Potvin,2 Kerry D Solomon1 1Carolina Eyecare Physicians, LLC, Mt. Pleasant, SC, USA; 2Science in Vision, Bend, OR, USACorrespondence: Kerry D SolomonCarolina Eyecare Physicians, LLC, 1101 Clarity Road, Suite 100, Mt Pleasant, SC 29464, USAEmail kerry.solomon@carolinaeyecare.comPurpose: To evaluate the vision, defocus curve, reading speed and patient satisfaction after implantation of an extended depth of focus (EDOF) IOL in one eye and a diffractive multifocal in the fellow eye.Setting: One clinical practice in the USA.Design: Prospective unmasked non-randomized clinical trial.Methods: Subjects presenting for routine cataract surgery interested in reducing their dependence on spectacles were enrolled. Study endpoints included uncorrected and distance-corrected binocular distance (4 m), intermediate (66 cm) and near (40 cm) visual acuity at 3 months. Additional endpoints included the residual refraction, spectacle independence, overall satisfaction with vision, visual symptoms, reading speed and defocus curve.Results: With a best distance correction, 77% (30/39) of subjects had 20/25 or better VA at distance, intermediate and near and nearly all subjects had 20/32 or better VA at all three distances. Defocus curve results showed mean continuous vision of 20/25 or better from plano to − 2.50 D. Nearly 80% (31/39) of subjects had 20/25 visual acuity from 0.00 D to − 2.50 D. The critical print size was between 0.3 and 0.4 logMAR (20/40 to 20/50 Snellen Equivalent). Spectacle independence was 100% at distance, 95% at intermediate and approximately 70% at near. The percentage of subjects who were “not at all” or “slightly” bothered by visual disturbances ranged from 64% (16/25) for Halos to 88% (22/25) for Starbursts.Conclusions: EDOF/bifocal IOL blended implantation results in at least 20/25 mean visual acuity from distance to near with good spectacle independence and low reports of severe visual disturbances.Keywords: extended depth of focus, EDOF, blended, presbyopia correctionSandoval HPPotvin RSolomon KDDove Medical Pressarticleextended depth of focusedofblendedpresbyopia correctionOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 14, Pp 2667-2677 (2020)
institution DOAJ
collection DOAJ
language EN
topic extended depth of focus
edof
blended
presbyopia correction
Ophthalmology
RE1-994
spellingShingle extended depth of focus
edof
blended
presbyopia correction
Ophthalmology
RE1-994
Sandoval HP
Potvin R
Solomon KD
Visual Acuity, Defocus Curve, Reading Speed and Patient Satisfaction with a Combined Extended Depth of Focus Intraocular Lens and Multifocal Intraocular Lens Modality
description Helga P Sandoval,1 Richard Potvin,2 Kerry D Solomon1 1Carolina Eyecare Physicians, LLC, Mt. Pleasant, SC, USA; 2Science in Vision, Bend, OR, USACorrespondence: Kerry D SolomonCarolina Eyecare Physicians, LLC, 1101 Clarity Road, Suite 100, Mt Pleasant, SC 29464, USAEmail kerry.solomon@carolinaeyecare.comPurpose: To evaluate the vision, defocus curve, reading speed and patient satisfaction after implantation of an extended depth of focus (EDOF) IOL in one eye and a diffractive multifocal in the fellow eye.Setting: One clinical practice in the USA.Design: Prospective unmasked non-randomized clinical trial.Methods: Subjects presenting for routine cataract surgery interested in reducing their dependence on spectacles were enrolled. Study endpoints included uncorrected and distance-corrected binocular distance (4 m), intermediate (66 cm) and near (40 cm) visual acuity at 3 months. Additional endpoints included the residual refraction, spectacle independence, overall satisfaction with vision, visual symptoms, reading speed and defocus curve.Results: With a best distance correction, 77% (30/39) of subjects had 20/25 or better VA at distance, intermediate and near and nearly all subjects had 20/32 or better VA at all three distances. Defocus curve results showed mean continuous vision of 20/25 or better from plano to − 2.50 D. Nearly 80% (31/39) of subjects had 20/25 visual acuity from 0.00 D to − 2.50 D. The critical print size was between 0.3 and 0.4 logMAR (20/40 to 20/50 Snellen Equivalent). Spectacle independence was 100% at distance, 95% at intermediate and approximately 70% at near. The percentage of subjects who were “not at all” or “slightly” bothered by visual disturbances ranged from 64% (16/25) for Halos to 88% (22/25) for Starbursts.Conclusions: EDOF/bifocal IOL blended implantation results in at least 20/25 mean visual acuity from distance to near with good spectacle independence and low reports of severe visual disturbances.Keywords: extended depth of focus, EDOF, blended, presbyopia correction
format article
author Sandoval HP
Potvin R
Solomon KD
author_facet Sandoval HP
Potvin R
Solomon KD
author_sort Sandoval HP
title Visual Acuity, Defocus Curve, Reading Speed and Patient Satisfaction with a Combined Extended Depth of Focus Intraocular Lens and Multifocal Intraocular Lens Modality
title_short Visual Acuity, Defocus Curve, Reading Speed and Patient Satisfaction with a Combined Extended Depth of Focus Intraocular Lens and Multifocal Intraocular Lens Modality
title_full Visual Acuity, Defocus Curve, Reading Speed and Patient Satisfaction with a Combined Extended Depth of Focus Intraocular Lens and Multifocal Intraocular Lens Modality
title_fullStr Visual Acuity, Defocus Curve, Reading Speed and Patient Satisfaction with a Combined Extended Depth of Focus Intraocular Lens and Multifocal Intraocular Lens Modality
title_full_unstemmed Visual Acuity, Defocus Curve, Reading Speed and Patient Satisfaction with a Combined Extended Depth of Focus Intraocular Lens and Multifocal Intraocular Lens Modality
title_sort visual acuity, defocus curve, reading speed and patient satisfaction with a combined extended depth of focus intraocular lens and multifocal intraocular lens modality
publisher Dove Medical Press
publishDate 2020
url https://doaj.org/article/fc6a7f9898cc4970b618e219bd547fd9
work_keys_str_mv AT sandovalhp visualacuitydefocuscurvereadingspeedandpatientsatisfactionwithacombinedextendeddepthoffocusintraocularlensandmultifocalintraocularlensmodality
AT potvinr visualacuitydefocuscurvereadingspeedandpatientsatisfactionwithacombinedextendeddepthoffocusintraocularlensandmultifocalintraocularlensmodality
AT solomonkd visualacuitydefocuscurvereadingspeedandpatientsatisfactionwithacombinedextendeddepthoffocusintraocularlensandmultifocalintraocularlensmodality
_version_ 1718385849214697472