Post-Buckling Spring Vibration Isolator Using Silicone Gel Column: A Theoretical and Experimental Study
Based on the design of a post-buckling silicone gel column (SGC), a novel type of low-frequency vibration isolator is presented, and the vibration isolation performance of this isolator is studied by combining theoretical analysis and experimental verification. The stiffness characteristics of the p...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
MDPI AG
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/fd032b7dfef84475be2214ef1f6786a0 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:fd032b7dfef84475be2214ef1f6786a0 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:fd032b7dfef84475be2214ef1f6786a02021-11-25T16:31:29ZPost-Buckling Spring Vibration Isolator Using Silicone Gel Column: A Theoretical and Experimental Study10.3390/app1122105592076-3417https://doaj.org/article/fd032b7dfef84475be2214ef1f6786a02021-11-01T00:00:00Zhttps://www.mdpi.com/2076-3417/11/22/10559https://doaj.org/toc/2076-3417Based on the design of a post-buckling silicone gel column (SGC), a novel type of low-frequency vibration isolator is presented, and the vibration isolation performance of this isolator is studied by combining theoretical analysis and experimental verification. The stiffness characteristics of the post-buckling SGC are derived, and its recovery force curves with different parameters are analyzed using two kinds of elliptic integral functions. Displacement transmissibility is formulated using harmonic balance method (HBM), and the influences of the excitation amplitude, damping ratio, SGC section diameter, and Young’s modulus are discussed in terms of the transmissibility. The performance of the SGC system is verified through a series of experimental studies based on the developed experimental prototype. The result shows that the proposed post-buckling spring vibration isolator has a good vibration isolation effect, especially in the low-frequency domain, which may provide a feasible novel design idea for a low-frequency vibration isolator.Ji-Hou YangXiao-Dong YangQing-Kai HanJin-Guo LiuMDPI AGarticlevibration isolatorsilicone gel columnpost-buckling springvibration transfer rateisolation experimentTechnologyTEngineering (General). Civil engineering (General)TA1-2040Biology (General)QH301-705.5PhysicsQC1-999ChemistryQD1-999ENApplied Sciences, Vol 11, Iss 10559, p 10559 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
vibration isolator silicone gel column post-buckling spring vibration transfer rate isolation experiment Technology T Engineering (General). Civil engineering (General) TA1-2040 Biology (General) QH301-705.5 Physics QC1-999 Chemistry QD1-999 |
spellingShingle |
vibration isolator silicone gel column post-buckling spring vibration transfer rate isolation experiment Technology T Engineering (General). Civil engineering (General) TA1-2040 Biology (General) QH301-705.5 Physics QC1-999 Chemistry QD1-999 Ji-Hou Yang Xiao-Dong Yang Qing-Kai Han Jin-Guo Liu Post-Buckling Spring Vibration Isolator Using Silicone Gel Column: A Theoretical and Experimental Study |
description |
Based on the design of a post-buckling silicone gel column (SGC), a novel type of low-frequency vibration isolator is presented, and the vibration isolation performance of this isolator is studied by combining theoretical analysis and experimental verification. The stiffness characteristics of the post-buckling SGC are derived, and its recovery force curves with different parameters are analyzed using two kinds of elliptic integral functions. Displacement transmissibility is formulated using harmonic balance method (HBM), and the influences of the excitation amplitude, damping ratio, SGC section diameter, and Young’s modulus are discussed in terms of the transmissibility. The performance of the SGC system is verified through a series of experimental studies based on the developed experimental prototype. The result shows that the proposed post-buckling spring vibration isolator has a good vibration isolation effect, especially in the low-frequency domain, which may provide a feasible novel design idea for a low-frequency vibration isolator. |
format |
article |
author |
Ji-Hou Yang Xiao-Dong Yang Qing-Kai Han Jin-Guo Liu |
author_facet |
Ji-Hou Yang Xiao-Dong Yang Qing-Kai Han Jin-Guo Liu |
author_sort |
Ji-Hou Yang |
title |
Post-Buckling Spring Vibration Isolator Using Silicone Gel Column: A Theoretical and Experimental Study |
title_short |
Post-Buckling Spring Vibration Isolator Using Silicone Gel Column: A Theoretical and Experimental Study |
title_full |
Post-Buckling Spring Vibration Isolator Using Silicone Gel Column: A Theoretical and Experimental Study |
title_fullStr |
Post-Buckling Spring Vibration Isolator Using Silicone Gel Column: A Theoretical and Experimental Study |
title_full_unstemmed |
Post-Buckling Spring Vibration Isolator Using Silicone Gel Column: A Theoretical and Experimental Study |
title_sort |
post-buckling spring vibration isolator using silicone gel column: a theoretical and experimental study |
publisher |
MDPI AG |
publishDate |
2021 |
url |
https://doaj.org/article/fd032b7dfef84475be2214ef1f6786a0 |
work_keys_str_mv |
AT jihouyang postbucklingspringvibrationisolatorusingsiliconegelcolumnatheoreticalandexperimentalstudy AT xiaodongyang postbucklingspringvibrationisolatorusingsiliconegelcolumnatheoreticalandexperimentalstudy AT qingkaihan postbucklingspringvibrationisolatorusingsiliconegelcolumnatheoreticalandexperimentalstudy AT jinguoliu postbucklingspringvibrationisolatorusingsiliconegelcolumnatheoreticalandexperimentalstudy |
_version_ |
1718413176959139840 |