COMPARISON OF CHARACTERISTICS OF THE CONVERTER-FED MOTOR AT SUPPLY FROM THE SINGLE-PHASE NETWORK AND FROM THE SOURCE OF THE DIRECT CURRENT

Purpose. Now even more often in various cars and mechanisms converter-fed motors are used. Their comparative characteristics with motors which are supplied from a network of a direct current are necessary for definition of the specific moment of motors which are supplied from the single-phase altern...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: V.B. Finkelshtein, A.B. Yegorov, A.M. Maleev
Formato: article
Lenguaje:EN
RU
UK
Publicado: National Technical University "Kharkiv Polytechnic Institute" 2015
Materias:
Acceso en línea:https://doaj.org/article/fd2ffc821c9a47d3b880357a522652a2
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:fd2ffc821c9a47d3b880357a522652a2
record_format dspace
spelling oai:doaj.org-article:fd2ffc821c9a47d3b880357a522652a22021-12-02T14:54:23ZCOMPARISON OF CHARACTERISTICS OF THE CONVERTER-FED MOTOR AT SUPPLY FROM THE SINGLE-PHASE NETWORK AND FROM THE SOURCE OF THE DIRECT CURRENT2074-272X2309-3404https://doaj.org/article/fd2ffc821c9a47d3b880357a522652a22015-08-01T00:00:00Zhttp://eie.khpi.edu.ua/article/view/48726/44945https://doaj.org/toc/2074-272Xhttps://doaj.org/toc/2309-3404Purpose. Now even more often in various cars and mechanisms converter-fed motors are used. Their comparative characteristics with motors which are supplied from a network of a direct current are necessary for definition of the specific moment of motors which are supplied from the single-phase alternating current main. Methodology. For the converter-fed motor with a ratio of teeth of the stator and a rotor 8/6 at supply from a single-phase network via the rectifier two groups of numerical experiments were carried out. Motor capacity with a constant frequency of rotation at various capacity of the capacitor at the exit of the rectifier and motor capacity at the current providing the most admissible excess of temperature of a winding are determined. Dependences of useful power on capacity size at the rectifier exit are received with a constant frequency of rotation, and also at invariable current. Results. On the basis of the made numerical experiment it is possible to conclude that due to fluctuation of tension (from 0 to 100 %) at the rectifier exit at power supply of the converter-fed motor from the single-phase alternating current main in comparison with the corresponding sizes at supply from a source of a direct current: • motor capacity at preservation of capacity of the capacitor at the exit of the rectifier and frequency of rotation decreases on 60 – 63 %; • at almost acceptable increase in capacity of the capacitor (approximately twice) power should be reduced by 50 %; • power deceleration at preservation of that size of current of the motor what took place at its food from a source of a direct current makes 40 % at preservation of size of capacity of the capacitor at the exit of the rectifier and 32 % at its doubling, the frequency of rotation decreases approximately on 13 – 15 %. Practical value. The specific moment can be determined by power sizes at single-phase supply, frequency of rotation and to the volume of a rotor, with an invariable frequency of rotation it decreases in comparison with the specific moment at power supply of the motor from a source of a direct current by 50 – 63 %.V.B. FinkelshteinA.B. YegorovA.M. MaleevNational Technical University "Kharkiv Polytechnic Institute"articleconverter-fed motormagnetic fluxsingle-phase network of supplycapacitypowersource of direct currentrotation frequencyElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENRUUKElectrical engineering & Electromechanics, Iss 4, Pp 15-19 (2015)
institution DOAJ
collection DOAJ
language EN
RU
UK
topic converter-fed motor
magnetic flux
single-phase network of supply
capacity
power
source of direct current
rotation frequency
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
spellingShingle converter-fed motor
magnetic flux
single-phase network of supply
capacity
power
source of direct current
rotation frequency
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
V.B. Finkelshtein
A.B. Yegorov
A.M. Maleev
COMPARISON OF CHARACTERISTICS OF THE CONVERTER-FED MOTOR AT SUPPLY FROM THE SINGLE-PHASE NETWORK AND FROM THE SOURCE OF THE DIRECT CURRENT
description Purpose. Now even more often in various cars and mechanisms converter-fed motors are used. Their comparative characteristics with motors which are supplied from a network of a direct current are necessary for definition of the specific moment of motors which are supplied from the single-phase alternating current main. Methodology. For the converter-fed motor with a ratio of teeth of the stator and a rotor 8/6 at supply from a single-phase network via the rectifier two groups of numerical experiments were carried out. Motor capacity with a constant frequency of rotation at various capacity of the capacitor at the exit of the rectifier and motor capacity at the current providing the most admissible excess of temperature of a winding are determined. Dependences of useful power on capacity size at the rectifier exit are received with a constant frequency of rotation, and also at invariable current. Results. On the basis of the made numerical experiment it is possible to conclude that due to fluctuation of tension (from 0 to 100 %) at the rectifier exit at power supply of the converter-fed motor from the single-phase alternating current main in comparison with the corresponding sizes at supply from a source of a direct current: • motor capacity at preservation of capacity of the capacitor at the exit of the rectifier and frequency of rotation decreases on 60 – 63 %; • at almost acceptable increase in capacity of the capacitor (approximately twice) power should be reduced by 50 %; • power deceleration at preservation of that size of current of the motor what took place at its food from a source of a direct current makes 40 % at preservation of size of capacity of the capacitor at the exit of the rectifier and 32 % at its doubling, the frequency of rotation decreases approximately on 13 – 15 %. Practical value. The specific moment can be determined by power sizes at single-phase supply, frequency of rotation and to the volume of a rotor, with an invariable frequency of rotation it decreases in comparison with the specific moment at power supply of the motor from a source of a direct current by 50 – 63 %.
format article
author V.B. Finkelshtein
A.B. Yegorov
A.M. Maleev
author_facet V.B. Finkelshtein
A.B. Yegorov
A.M. Maleev
author_sort V.B. Finkelshtein
title COMPARISON OF CHARACTERISTICS OF THE CONVERTER-FED MOTOR AT SUPPLY FROM THE SINGLE-PHASE NETWORK AND FROM THE SOURCE OF THE DIRECT CURRENT
title_short COMPARISON OF CHARACTERISTICS OF THE CONVERTER-FED MOTOR AT SUPPLY FROM THE SINGLE-PHASE NETWORK AND FROM THE SOURCE OF THE DIRECT CURRENT
title_full COMPARISON OF CHARACTERISTICS OF THE CONVERTER-FED MOTOR AT SUPPLY FROM THE SINGLE-PHASE NETWORK AND FROM THE SOURCE OF THE DIRECT CURRENT
title_fullStr COMPARISON OF CHARACTERISTICS OF THE CONVERTER-FED MOTOR AT SUPPLY FROM THE SINGLE-PHASE NETWORK AND FROM THE SOURCE OF THE DIRECT CURRENT
title_full_unstemmed COMPARISON OF CHARACTERISTICS OF THE CONVERTER-FED MOTOR AT SUPPLY FROM THE SINGLE-PHASE NETWORK AND FROM THE SOURCE OF THE DIRECT CURRENT
title_sort comparison of characteristics of the converter-fed motor at supply from the single-phase network and from the source of the direct current
publisher National Technical University "Kharkiv Polytechnic Institute"
publishDate 2015
url https://doaj.org/article/fd2ffc821c9a47d3b880357a522652a2
work_keys_str_mv AT vbfinkelshtein comparisonofcharacteristicsoftheconverterfedmotoratsupplyfromthesinglephasenetworkandfromthesourceofthedirectcurrent
AT abyegorov comparisonofcharacteristicsoftheconverterfedmotoratsupplyfromthesinglephasenetworkandfromthesourceofthedirectcurrent
AT ammaleev comparisonofcharacteristicsoftheconverterfedmotoratsupplyfromthesinglephasenetworkandfromthesourceofthedirectcurrent
_version_ 1718389426879463424