A method for ultrasound probe calibration based on arbitrary wire phantom

To create a freehand three-dimensional ultrasound system for image-guided intervention, ultrasound probe calibration process plays an important role. This paper introduces a novel method, based on arbitrary wire phantom, to achieve both spatial and temporal calibration for ultrasound probe. Spatial...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Chunxu Shen, Liushuai Lyu, Guangzhi Wang, Jian Wu
Formato: article
Lenguaje:EN
Publicado: Taylor & Francis Group 2019
Materias:
Acceso en línea:https://doaj.org/article/fd536d92a2e34299bdd7a95b5444c5d6
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:fd536d92a2e34299bdd7a95b5444c5d6
record_format dspace
spelling oai:doaj.org-article:fd536d92a2e34299bdd7a95b5444c5d62021-11-04T15:51:55ZA method for ultrasound probe calibration based on arbitrary wire phantom2331-191610.1080/23311916.2019.1592739https://doaj.org/article/fd536d92a2e34299bdd7a95b5444c5d62019-01-01T00:00:00Zhttp://dx.doi.org/10.1080/23311916.2019.1592739https://doaj.org/toc/2331-1916To create a freehand three-dimensional ultrasound system for image-guided intervention, ultrasound probe calibration process plays an important role. This paper introduces a novel method, based on arbitrary wire phantom, to achieve both spatial and temporal calibration for ultrasound probe. Spatial calibration is realized by solving an optimization problem established by the wires and corresponding intersections in ultrasound plane. Next, temporal calibration is achieved by processing ultrasound image sequence and the corresponding position of optical localizer mounted to ultrasound probe. In order to make up for the deficiency of geometry structure in arbitrary phantom, we develop a point-recognition algorithm to determine the correspondence between wires in phantom space and intersections in ultrasound image space. Extensive comparative experiment is conducted on N-wire phantom and our phantom in 20 independent trials to fully evaluate precision, accuracy, and robustness of proposed calibration method. Shallow probe experimental result shows that proposed method improves average calibration precision to 0.896 mm and accuracy to 1.022 mm, compared to 0.938 and 1.140 mm using N-wire, respectively. Further, we also perform extra independent trials to evaluate the impact of deep image for the proposed method. Result shows the precision ranges from 0.740 to 1.178 mm, and the accuracy ranges from 0.939 to 1.400 mm, which indicates proposed method is potential for probe calibration in ultrasound image-guided intervention.Chunxu ShenLiushuai LyuGuangzhi WangJian WuTaylor & Francis Grouparticlearbitrary-wire phantomprobe calibrationultrasound-guided interventionEngineering (General). Civil engineering (General)TA1-2040ENCogent Engineering, Vol 6, Iss 1 (2019)
institution DOAJ
collection DOAJ
language EN
topic arbitrary-wire phantom
probe calibration
ultrasound-guided intervention
Engineering (General). Civil engineering (General)
TA1-2040
spellingShingle arbitrary-wire phantom
probe calibration
ultrasound-guided intervention
Engineering (General). Civil engineering (General)
TA1-2040
Chunxu Shen
Liushuai Lyu
Guangzhi Wang
Jian Wu
A method for ultrasound probe calibration based on arbitrary wire phantom
description To create a freehand three-dimensional ultrasound system for image-guided intervention, ultrasound probe calibration process plays an important role. This paper introduces a novel method, based on arbitrary wire phantom, to achieve both spatial and temporal calibration for ultrasound probe. Spatial calibration is realized by solving an optimization problem established by the wires and corresponding intersections in ultrasound plane. Next, temporal calibration is achieved by processing ultrasound image sequence and the corresponding position of optical localizer mounted to ultrasound probe. In order to make up for the deficiency of geometry structure in arbitrary phantom, we develop a point-recognition algorithm to determine the correspondence between wires in phantom space and intersections in ultrasound image space. Extensive comparative experiment is conducted on N-wire phantom and our phantom in 20 independent trials to fully evaluate precision, accuracy, and robustness of proposed calibration method. Shallow probe experimental result shows that proposed method improves average calibration precision to 0.896 mm and accuracy to 1.022 mm, compared to 0.938 and 1.140 mm using N-wire, respectively. Further, we also perform extra independent trials to evaluate the impact of deep image for the proposed method. Result shows the precision ranges from 0.740 to 1.178 mm, and the accuracy ranges from 0.939 to 1.400 mm, which indicates proposed method is potential for probe calibration in ultrasound image-guided intervention.
format article
author Chunxu Shen
Liushuai Lyu
Guangzhi Wang
Jian Wu
author_facet Chunxu Shen
Liushuai Lyu
Guangzhi Wang
Jian Wu
author_sort Chunxu Shen
title A method for ultrasound probe calibration based on arbitrary wire phantom
title_short A method for ultrasound probe calibration based on arbitrary wire phantom
title_full A method for ultrasound probe calibration based on arbitrary wire phantom
title_fullStr A method for ultrasound probe calibration based on arbitrary wire phantom
title_full_unstemmed A method for ultrasound probe calibration based on arbitrary wire phantom
title_sort method for ultrasound probe calibration based on arbitrary wire phantom
publisher Taylor & Francis Group
publishDate 2019
url https://doaj.org/article/fd536d92a2e34299bdd7a95b5444c5d6
work_keys_str_mv AT chunxushen amethodforultrasoundprobecalibrationbasedonarbitrarywirephantom
AT liushuailyu amethodforultrasoundprobecalibrationbasedonarbitrarywirephantom
AT guangzhiwang amethodforultrasoundprobecalibrationbasedonarbitrarywirephantom
AT jianwu amethodforultrasoundprobecalibrationbasedonarbitrarywirephantom
AT chunxushen methodforultrasoundprobecalibrationbasedonarbitrarywirephantom
AT liushuailyu methodforultrasoundprobecalibrationbasedonarbitrarywirephantom
AT guangzhiwang methodforultrasoundprobecalibrationbasedonarbitrarywirephantom
AT jianwu methodforultrasoundprobecalibrationbasedonarbitrarywirephantom
_version_ 1718444752353886208