Torsional ultrasound mode versus combined torsional and conventional ultrasound mode phacoemulsification for eyes with hard cataract

Mohamed A Fakhry1,2, Malak I El Shazly11Department of Ophthalmology, Kasr El Aini Hospital, Cairo University, Cairo, Egypt; 2Cataract and Refractive Consultant, International Eye Hospital, Cairo, EgyptPurpose: To compare torsional versus combined torsional and conventional ultrasound modes in hard c...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Fakhry MA, El Shazly MI
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2011
Materias:
Acceso en línea:https://doaj.org/article/fd9d978a9d4f4a9c8c1e89b1c956d97b
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:fd9d978a9d4f4a9c8c1e89b1c956d97b
record_format dspace
spelling oai:doaj.org-article:fd9d978a9d4f4a9c8c1e89b1c956d97b2021-12-02T02:07:40ZTorsional ultrasound mode versus combined torsional and conventional ultrasound mode phacoemulsification for eyes with hard cataract1177-54671177-5483https://doaj.org/article/fd9d978a9d4f4a9c8c1e89b1c956d97b2011-07-01T00:00:00Zhttp://www.dovepress.com/torsional-ultrasound-mode-versus-combined-torsional-and-conventional-u-a7882https://doaj.org/toc/1177-5467https://doaj.org/toc/1177-5483Mohamed A Fakhry1,2, Malak I El Shazly11Department of Ophthalmology, Kasr El Aini Hospital, Cairo University, Cairo, Egypt; 2Cataract and Refractive Consultant, International Eye Hospital, Cairo, EgyptPurpose: To compare torsional versus combined torsional and conventional ultrasound modes in hard cataract surgery regarding ultrasound energy and time and effect on corneal endothelium.Settings: Kasr El Aini hospital, Cairo University, and International Eye Hospital, Cairo, Egypt.Methodology: Ninety-eight eyes of 63 patients were enrolled in this prospective comparative randomized masked clinical study. All eyes had nuclear cataracts of grades III and IV using the Lens Opacities Classification System III (LOCS III). Two groups were included, each having an equal number of eyes (49). The treatment for group A was combined torsional and conventional US mode phacoemulsification, and for group B torsional US mode phacoemulsification only. Pre- and post-operative assessments included best corrected visual acuity (BCVA), intraocular pressure (IOP), slit-lamp evaluation, and fundoscopic evaluation. Endothelial cell density (ECD) and central corneal thickness (CCT) were measured preoperatively, 1 day, 7 days, and 1 month postoperatively. All eyes were operated on using the Alcon Infiniti System (Alcon, Fort Worth, TX) with the quick chop technique. All eyes were implanted with AcrySof SA60AT (Alcon) intraocular lens (IOL). The main phaco outcome parameters included the mean ultrasound time (UST), the mean cumulative dissipated energy (CDE), and the percent of average torsional amplitude in position 3 (%TUSiP3).Results: Improvement in BCVA was statistically significant in both groups (P < 0.001). Comparing UST and CDE for both groups revealed results favoring the pure torsional group (P = 0.002 and P < 0.001 for UST; P = 0.058 and P = 0.009 for CDE). As for %TUSiP3, readings were higher for the pure torsional group (P = 0.03 and P = 0.01). All changes of CCT, and ECD over time were found statistically significant using one-way ANOVA testing (P < 0.001).Conclusion: Both modes are safe in hard cataract surgery, however the pure torsional mode showed less US energy used.Keywords: torsional, cumulative dissipated energy, cataract Fakhry MAEl Shazly MIDove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2011, Iss default, Pp 973-978 (2011)
institution DOAJ
collection DOAJ
language EN
topic Ophthalmology
RE1-994
spellingShingle Ophthalmology
RE1-994
Fakhry MA
El Shazly MI
Torsional ultrasound mode versus combined torsional and conventional ultrasound mode phacoemulsification for eyes with hard cataract
description Mohamed A Fakhry1,2, Malak I El Shazly11Department of Ophthalmology, Kasr El Aini Hospital, Cairo University, Cairo, Egypt; 2Cataract and Refractive Consultant, International Eye Hospital, Cairo, EgyptPurpose: To compare torsional versus combined torsional and conventional ultrasound modes in hard cataract surgery regarding ultrasound energy and time and effect on corneal endothelium.Settings: Kasr El Aini hospital, Cairo University, and International Eye Hospital, Cairo, Egypt.Methodology: Ninety-eight eyes of 63 patients were enrolled in this prospective comparative randomized masked clinical study. All eyes had nuclear cataracts of grades III and IV using the Lens Opacities Classification System III (LOCS III). Two groups were included, each having an equal number of eyes (49). The treatment for group A was combined torsional and conventional US mode phacoemulsification, and for group B torsional US mode phacoemulsification only. Pre- and post-operative assessments included best corrected visual acuity (BCVA), intraocular pressure (IOP), slit-lamp evaluation, and fundoscopic evaluation. Endothelial cell density (ECD) and central corneal thickness (CCT) were measured preoperatively, 1 day, 7 days, and 1 month postoperatively. All eyes were operated on using the Alcon Infiniti System (Alcon, Fort Worth, TX) with the quick chop technique. All eyes were implanted with AcrySof SA60AT (Alcon) intraocular lens (IOL). The main phaco outcome parameters included the mean ultrasound time (UST), the mean cumulative dissipated energy (CDE), and the percent of average torsional amplitude in position 3 (%TUSiP3).Results: Improvement in BCVA was statistically significant in both groups (P < 0.001). Comparing UST and CDE for both groups revealed results favoring the pure torsional group (P = 0.002 and P < 0.001 for UST; P = 0.058 and P = 0.009 for CDE). As for %TUSiP3, readings were higher for the pure torsional group (P = 0.03 and P = 0.01). All changes of CCT, and ECD over time were found statistically significant using one-way ANOVA testing (P < 0.001).Conclusion: Both modes are safe in hard cataract surgery, however the pure torsional mode showed less US energy used.Keywords: torsional, cumulative dissipated energy, cataract 
format article
author Fakhry MA
El Shazly MI
author_facet Fakhry MA
El Shazly MI
author_sort Fakhry MA
title Torsional ultrasound mode versus combined torsional and conventional ultrasound mode phacoemulsification for eyes with hard cataract
title_short Torsional ultrasound mode versus combined torsional and conventional ultrasound mode phacoemulsification for eyes with hard cataract
title_full Torsional ultrasound mode versus combined torsional and conventional ultrasound mode phacoemulsification for eyes with hard cataract
title_fullStr Torsional ultrasound mode versus combined torsional and conventional ultrasound mode phacoemulsification for eyes with hard cataract
title_full_unstemmed Torsional ultrasound mode versus combined torsional and conventional ultrasound mode phacoemulsification for eyes with hard cataract
title_sort torsional ultrasound mode versus combined torsional and conventional ultrasound mode phacoemulsification for eyes with hard cataract
publisher Dove Medical Press
publishDate 2011
url https://doaj.org/article/fd9d978a9d4f4a9c8c1e89b1c956d97b
work_keys_str_mv AT fakhryma torsionalultrasoundmodeversuscombinedtorsionalandconventionalultrasoundmodephacoemulsificationforeyeswithhardcataract
AT elshazlymi torsionalultrasoundmodeversuscombinedtorsionalandconventionalultrasoundmodephacoemulsificationforeyeswithhardcataract
_version_ 1718402751394742272