Underfloor Heating Using Room Air Conditioners with Air Source Heat Pump in a Foundation Insulation House
A good thermal environment is important in a place where occupants stay for a long time. Since heating a house consumes a lot of energy, an energy-efficient heating method will be required. Then, by combining a heat pump and underfloor heating, there is a possibility that both thermal comfort and en...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
MDPI AG
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/fe4f4757ef434de0bb7c608bc7e8599d |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:fe4f4757ef434de0bb7c608bc7e8599d |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:fe4f4757ef434de0bb7c608bc7e8599d2021-11-11T15:51:09ZUnderfloor Heating Using Room Air Conditioners with Air Source Heat Pump in a Foundation Insulation House10.3390/en142170341996-1073https://doaj.org/article/fe4f4757ef434de0bb7c608bc7e8599d2021-10-01T00:00:00Zhttps://www.mdpi.com/1996-1073/14/21/7034https://doaj.org/toc/1996-1073A good thermal environment is important in a place where occupants stay for a long time. Since heating a house consumes a lot of energy, an energy-efficient heating method will be required. Then, by combining a heat pump and underfloor heating, there is a possibility that both thermal comfort and energy saving can be achieved. The survey was conducted on a detached house located in Nagano Prefecture, Japan. The average outside air temperature was 4.2 °C. This study investigated the indoor thermal environment, evaluated the operating performance of the heat pump, and calculated the heat load by two-dimensional analysis. More than 80% of the subjects were satisfied with the thermal environment and the neutral temperature was 18.9 °C. In the operation of the heat pump, defrost operation was confirmed, but the average COP was 2.9, and it operated efficiently. In addition, the heat loss from the foundation slab was examined. Proper insulation placement has shown the potential to reduce heat loss. In conclusion, the use of heat pumps as a heat source has been shown to be efficient even in cold climates, and this study supports the construction of new heating methods.Hiroki IkedaYasushi OoiTakashi NakayaMDPI AGarticlecold regionhouseheated crawl spaceair source heat pumpfoundation insulationthermal comfortTechnologyTENEnergies, Vol 14, Iss 7034, p 7034 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
cold region house heated crawl space air source heat pump foundation insulation thermal comfort Technology T |
spellingShingle |
cold region house heated crawl space air source heat pump foundation insulation thermal comfort Technology T Hiroki Ikeda Yasushi Ooi Takashi Nakaya Underfloor Heating Using Room Air Conditioners with Air Source Heat Pump in a Foundation Insulation House |
description |
A good thermal environment is important in a place where occupants stay for a long time. Since heating a house consumes a lot of energy, an energy-efficient heating method will be required. Then, by combining a heat pump and underfloor heating, there is a possibility that both thermal comfort and energy saving can be achieved. The survey was conducted on a detached house located in Nagano Prefecture, Japan. The average outside air temperature was 4.2 °C. This study investigated the indoor thermal environment, evaluated the operating performance of the heat pump, and calculated the heat load by two-dimensional analysis. More than 80% of the subjects were satisfied with the thermal environment and the neutral temperature was 18.9 °C. In the operation of the heat pump, defrost operation was confirmed, but the average COP was 2.9, and it operated efficiently. In addition, the heat loss from the foundation slab was examined. Proper insulation placement has shown the potential to reduce heat loss. In conclusion, the use of heat pumps as a heat source has been shown to be efficient even in cold climates, and this study supports the construction of new heating methods. |
format |
article |
author |
Hiroki Ikeda Yasushi Ooi Takashi Nakaya |
author_facet |
Hiroki Ikeda Yasushi Ooi Takashi Nakaya |
author_sort |
Hiroki Ikeda |
title |
Underfloor Heating Using Room Air Conditioners with Air Source Heat Pump in a Foundation Insulation House |
title_short |
Underfloor Heating Using Room Air Conditioners with Air Source Heat Pump in a Foundation Insulation House |
title_full |
Underfloor Heating Using Room Air Conditioners with Air Source Heat Pump in a Foundation Insulation House |
title_fullStr |
Underfloor Heating Using Room Air Conditioners with Air Source Heat Pump in a Foundation Insulation House |
title_full_unstemmed |
Underfloor Heating Using Room Air Conditioners with Air Source Heat Pump in a Foundation Insulation House |
title_sort |
underfloor heating using room air conditioners with air source heat pump in a foundation insulation house |
publisher |
MDPI AG |
publishDate |
2021 |
url |
https://doaj.org/article/fe4f4757ef434de0bb7c608bc7e8599d |
work_keys_str_mv |
AT hirokiikeda underfloorheatingusingroomairconditionerswithairsourceheatpumpinafoundationinsulationhouse AT yasushiooi underfloorheatingusingroomairconditionerswithairsourceheatpumpinafoundationinsulationhouse AT takashinakaya underfloorheatingusingroomairconditionerswithairsourceheatpumpinafoundationinsulationhouse |
_version_ |
1718433420923633664 |