A compound control strategy of three‐phase Vienna rectifier under unbalanced grid voltage

Abstract When traditional finite‐set predictive power control is applied to Vienna rectifier, the input current will produce a large number of third harmonics under unbalanced power network, which will seriously affect the normal operation of Vienna rectifier. This paper proposes a compound control...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Xingtian Feng, Yongming Sun, Xiao Cui, Wenzhong Ma, Yubin Wang
Formato: article
Lenguaje:EN
Publicado: Wiley 2021
Materias:
Acceso en línea:https://doaj.org/article/fe66104c2af545d2b6d8eb81bc474226
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:fe66104c2af545d2b6d8eb81bc474226
record_format dspace
spelling oai:doaj.org-article:fe66104c2af545d2b6d8eb81bc4742262021-11-22T13:36:44ZA compound control strategy of three‐phase Vienna rectifier under unbalanced grid voltage1755-45431755-453510.1049/pel2.12202https://doaj.org/article/fe66104c2af545d2b6d8eb81bc4742262021-12-01T00:00:00Zhttps://doi.org/10.1049/pel2.12202https://doaj.org/toc/1755-4535https://doaj.org/toc/1755-4543Abstract When traditional finite‐set predictive power control is applied to Vienna rectifier, the input current will produce a large number of third harmonics under unbalanced power network, which will seriously affect the normal operation of Vienna rectifier. This paper proposes a compound control strategy for three‐phase Vienna rectifier based on grid imbalance. And the new finite control set‐model predictive direct power control (N‐FCS‐MPDPC) is used in the inner current loop. By introducing a redefined reactive power, this method can effectively control the second harmonic of instantaneous active power and the second harmonic of instantaneous reactive power at the same time, and realizes the normal operation of Vienna rectifier under the condition of unbalanced power grid. Linear auto disturbance rejection control (LADRC) is adopted in the outer voltage loop, which overcomes the problem of voltage overshoot and slow dynamic response in PI control. Furthermore, in order to solve the difficulty of grid‐side voltage acquisition when the grid is unbalanced, a virtual flux based no‐grid voltage sensor is introduced to measure the grid voltage. Simulation, along with experimental results, is presented to show that the proposed control strategy has good robustness and fast tracking performance under the condition of power grid imbalance.Xingtian FengYongming SunXiao CuiWenzhong MaYubin WangWileyarticleElectronicsTK7800-8360ENIET Power Electronics, Vol 14, Iss 16, Pp 2574-2584 (2021)
institution DOAJ
collection DOAJ
language EN
topic Electronics
TK7800-8360
spellingShingle Electronics
TK7800-8360
Xingtian Feng
Yongming Sun
Xiao Cui
Wenzhong Ma
Yubin Wang
A compound control strategy of three‐phase Vienna rectifier under unbalanced grid voltage
description Abstract When traditional finite‐set predictive power control is applied to Vienna rectifier, the input current will produce a large number of third harmonics under unbalanced power network, which will seriously affect the normal operation of Vienna rectifier. This paper proposes a compound control strategy for three‐phase Vienna rectifier based on grid imbalance. And the new finite control set‐model predictive direct power control (N‐FCS‐MPDPC) is used in the inner current loop. By introducing a redefined reactive power, this method can effectively control the second harmonic of instantaneous active power and the second harmonic of instantaneous reactive power at the same time, and realizes the normal operation of Vienna rectifier under the condition of unbalanced power grid. Linear auto disturbance rejection control (LADRC) is adopted in the outer voltage loop, which overcomes the problem of voltage overshoot and slow dynamic response in PI control. Furthermore, in order to solve the difficulty of grid‐side voltage acquisition when the grid is unbalanced, a virtual flux based no‐grid voltage sensor is introduced to measure the grid voltage. Simulation, along with experimental results, is presented to show that the proposed control strategy has good robustness and fast tracking performance under the condition of power grid imbalance.
format article
author Xingtian Feng
Yongming Sun
Xiao Cui
Wenzhong Ma
Yubin Wang
author_facet Xingtian Feng
Yongming Sun
Xiao Cui
Wenzhong Ma
Yubin Wang
author_sort Xingtian Feng
title A compound control strategy of three‐phase Vienna rectifier under unbalanced grid voltage
title_short A compound control strategy of three‐phase Vienna rectifier under unbalanced grid voltage
title_full A compound control strategy of three‐phase Vienna rectifier under unbalanced grid voltage
title_fullStr A compound control strategy of three‐phase Vienna rectifier under unbalanced grid voltage
title_full_unstemmed A compound control strategy of three‐phase Vienna rectifier under unbalanced grid voltage
title_sort compound control strategy of three‐phase vienna rectifier under unbalanced grid voltage
publisher Wiley
publishDate 2021
url https://doaj.org/article/fe66104c2af545d2b6d8eb81bc474226
work_keys_str_mv AT xingtianfeng acompoundcontrolstrategyofthreephaseviennarectifierunderunbalancedgridvoltage
AT yongmingsun acompoundcontrolstrategyofthreephaseviennarectifierunderunbalancedgridvoltage
AT xiaocui acompoundcontrolstrategyofthreephaseviennarectifierunderunbalancedgridvoltage
AT wenzhongma acompoundcontrolstrategyofthreephaseviennarectifierunderunbalancedgridvoltage
AT yubinwang acompoundcontrolstrategyofthreephaseviennarectifierunderunbalancedgridvoltage
AT xingtianfeng compoundcontrolstrategyofthreephaseviennarectifierunderunbalancedgridvoltage
AT yongmingsun compoundcontrolstrategyofthreephaseviennarectifierunderunbalancedgridvoltage
AT xiaocui compoundcontrolstrategyofthreephaseviennarectifierunderunbalancedgridvoltage
AT wenzhongma compoundcontrolstrategyofthreephaseviennarectifierunderunbalancedgridvoltage
AT yubinwang compoundcontrolstrategyofthreephaseviennarectifierunderunbalancedgridvoltage
_version_ 1718417593213124608