Objective: To evaluate the necessity and effectiveness of a preplanned technique for drilling during transcanal endoscopic ear surgery. Methods: Study design: Retrospective case series study from June 2011 to June 2015. Setting: Private tertiary care hospital. Patients: Eighty-five ears of 78 patien...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autor principal: Sheikh Shawkat Kamal
Formato: article
Lenguaje:EN
Publicado: KeAi Communications Co., Ltd. 2021
Materias:
Acceso en línea:https://doaj.org/article/fef2457e47634b63b16b59468dfcc473
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:fef2457e47634b63b16b59468dfcc473
record_format dspace
spelling oai:doaj.org-article:fef2457e47634b63b16b59468dfcc4732021-12-02T17:29:50ZA worthy technique for transcanal drilling during endoscopic ear surgery2095-881110.1016/j.wjorl.2020.04.005https://doaj.org/article/fef2457e47634b63b16b59468dfcc4732021-10-01T00:00:00Zhttp://www.sciencedirect.com/science/article/pii/S2095881120300524https://doaj.org/toc/2095-8811Objective: To evaluate the necessity and effectiveness of a preplanned technique for drilling during transcanal endoscopic ear surgery. Methods: Study design: Retrospective case series study from June 2011 to June 2015. Setting: Private tertiary care hospital. Patients: Eighty-five ears of 78 patients, age ranging from 9 to 57 years underwent transcanal endoscopic drilling for various types of pathology in their middle and external ear. Interventions: Application of a preplanned technique for transcanal drilling in endoscopic ear surgery that involved short timed drilling with use of intermittent irrigation and suction. Every events of the procedure were done one after another with the single hand of the surgeon. An attachment providing protecting sheath around rotating burr was used during each time of drilling. Main outcomes measure: Efficacy of such drilling technique in single handed endoscopic ear surgery. Presence of any postoperative thermal injury of facial nerve and any lacerated injury of skin of external ear. Results: This preplanned technique was found suitable for transcanal endoscopic drilling with the single hand of the surgeon. Postoperative facial nerve palsy or laceration of skin of external ear was not noted in any patient. Conclusion: After using the present technique, transcanal endoscopic drilling could be done easily and safely with single hand of the surgeon.Sheikh Shawkat KamalKeAi Communications Co., Ltd.articleEndoscopicTranscanalDrilling techniqueOtorhinolaryngologyRF1-547SurgeryRD1-811ENWorld Journal of Otorhinolaryngology-Head and Neck Surgery, Vol 7, Iss 4, Pp 265-269 (2021)
institution DOAJ
collection DOAJ
language EN
topic Endoscopic
Transcanal
Drilling technique
Otorhinolaryngology
RF1-547
Surgery
RD1-811
spellingShingle Endoscopic
Transcanal
Drilling technique
Otorhinolaryngology
RF1-547
Surgery
RD1-811
Sheikh Shawkat Kamal
A worthy technique for transcanal drilling during endoscopic ear surgery
description Objective: To evaluate the necessity and effectiveness of a preplanned technique for drilling during transcanal endoscopic ear surgery. Methods: Study design: Retrospective case series study from June 2011 to June 2015. Setting: Private tertiary care hospital. Patients: Eighty-five ears of 78 patients, age ranging from 9 to 57 years underwent transcanal endoscopic drilling for various types of pathology in their middle and external ear. Interventions: Application of a preplanned technique for transcanal drilling in endoscopic ear surgery that involved short timed drilling with use of intermittent irrigation and suction. Every events of the procedure were done one after another with the single hand of the surgeon. An attachment providing protecting sheath around rotating burr was used during each time of drilling. Main outcomes measure: Efficacy of such drilling technique in single handed endoscopic ear surgery. Presence of any postoperative thermal injury of facial nerve and any lacerated injury of skin of external ear. Results: This preplanned technique was found suitable for transcanal endoscopic drilling with the single hand of the surgeon. Postoperative facial nerve palsy or laceration of skin of external ear was not noted in any patient. Conclusion: After using the present technique, transcanal endoscopic drilling could be done easily and safely with single hand of the surgeon.
format article
author Sheikh Shawkat Kamal
author_facet Sheikh Shawkat Kamal
author_sort Sheikh Shawkat Kamal
title A worthy technique for transcanal drilling during endoscopic ear surgery
title_short A worthy technique for transcanal drilling during endoscopic ear surgery
title_full A worthy technique for transcanal drilling during endoscopic ear surgery
title_fullStr A worthy technique for transcanal drilling during endoscopic ear surgery
title_full_unstemmed A worthy technique for transcanal drilling during endoscopic ear surgery
title_sort worthy technique for transcanal drilling during endoscopic ear surgery
publisher KeAi Communications Co., Ltd.
publishDate 2021
url https://doaj.org/article/fef2457e47634b63b16b59468dfcc473
work_keys_str_mv AT sheikhshawkatkamal aworthytechniquefortranscanaldrillingduringendoscopicearsurgery
AT sheikhshawkatkamal worthytechniquefortranscanaldrillingduringendoscopicearsurgery
_version_ 1718380770118074368