Zone 0 Aortic Arch Reconstruction Using the RelayBranch Thoracic Stent Graft

Endovascular therapies have had a considerable impact on contemporary management of thoracic aortic disease. Still, with the anatomic challenges of the aortic arch, endovascular experience with devices that traverse the arch and deploy in the Zone 0 position remains limited. We report the first Cana...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: R. Scott McClure, MD, Kenton L. Rommens, MD, Eric J. Herget, MD, Oliver Halliwell, MD, Randy D. Moore, MD
Formato: article
Lenguaje:EN
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://doaj.org/article/ff35b9301ea345e3985d5bd571ea8586
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:ff35b9301ea345e3985d5bd571ea8586
record_format dspace
spelling oai:doaj.org-article:ff35b9301ea345e3985d5bd571ea85862021-11-26T04:38:10ZZone 0 Aortic Arch Reconstruction Using the RelayBranch Thoracic Stent Graft2589-790X10.1016/j.cjco.2021.05.013https://doaj.org/article/ff35b9301ea345e3985d5bd571ea85862021-10-01T00:00:00Zhttp://www.sciencedirect.com/science/article/pii/S2589790X21001463https://doaj.org/toc/2589-790XEndovascular therapies have had a considerable impact on contemporary management of thoracic aortic disease. Still, with the anatomic challenges of the aortic arch, endovascular experience with devices that traverse the arch and deploy in the Zone 0 position remains limited. We report the first Canadian experience with the RelayBranch Thoracic Stent Graft (Terumo Aortic, Sunrise, FL) with Zone 0 deployment for total endovascular aortic arch repair in a patient at very high risk for redo open surgery. We demonstrate safe deployment of the device and successful treatment of a type 1A endoleak. Features of the RelayBranch design that mitigate challenges of arch deployment are also discussed. Résumé: Les traitements endovasculaires ont eu un impact considérable sur la gestion contemporaine des pathologies de l'aorte thoracique. Pourtant, en raison des contraintes anatomiques de la crosse aortique, l'expérience endovasculaire avec des dispositifs qui traversent la crosse et se déploient dans la zone 0 reste limitée. Nous rapportons la première expérience canadienne de l'endoprothèse thoracique RelayBranch avec déploiement (Terumo Aortic, Sunrise, FL) en zone 0 pour une réparation endovasculaire totale de la crosse aortique chez un patient présentant un risque très élevé de reprise de chirurgie ouverte. Nous décrivons le déploiement en toute sécurité du dispositif et le traitement réussi d'une endofuite de type 1A. Enfin, nous examinons les caractéristiques du système RelayBranch qui limitent les difficultés liées au déploiement du dispositif dans la crosse aortique.R. Scott McClure, MDKenton L. Rommens, MDEric J. Herget, MDOliver Halliwell, MDRandy D. Moore, MDElsevierarticleDiseases of the circulatory (Cardiovascular) systemRC666-701ENCJC Open, Vol 3, Iss 10, Pp 1307-1309 (2021)
institution DOAJ
collection DOAJ
language EN
topic Diseases of the circulatory (Cardiovascular) system
RC666-701
spellingShingle Diseases of the circulatory (Cardiovascular) system
RC666-701
R. Scott McClure, MD
Kenton L. Rommens, MD
Eric J. Herget, MD
Oliver Halliwell, MD
Randy D. Moore, MD
Zone 0 Aortic Arch Reconstruction Using the RelayBranch Thoracic Stent Graft
description Endovascular therapies have had a considerable impact on contemporary management of thoracic aortic disease. Still, with the anatomic challenges of the aortic arch, endovascular experience with devices that traverse the arch and deploy in the Zone 0 position remains limited. We report the first Canadian experience with the RelayBranch Thoracic Stent Graft (Terumo Aortic, Sunrise, FL) with Zone 0 deployment for total endovascular aortic arch repair in a patient at very high risk for redo open surgery. We demonstrate safe deployment of the device and successful treatment of a type 1A endoleak. Features of the RelayBranch design that mitigate challenges of arch deployment are also discussed. Résumé: Les traitements endovasculaires ont eu un impact considérable sur la gestion contemporaine des pathologies de l'aorte thoracique. Pourtant, en raison des contraintes anatomiques de la crosse aortique, l'expérience endovasculaire avec des dispositifs qui traversent la crosse et se déploient dans la zone 0 reste limitée. Nous rapportons la première expérience canadienne de l'endoprothèse thoracique RelayBranch avec déploiement (Terumo Aortic, Sunrise, FL) en zone 0 pour une réparation endovasculaire totale de la crosse aortique chez un patient présentant un risque très élevé de reprise de chirurgie ouverte. Nous décrivons le déploiement en toute sécurité du dispositif et le traitement réussi d'une endofuite de type 1A. Enfin, nous examinons les caractéristiques du système RelayBranch qui limitent les difficultés liées au déploiement du dispositif dans la crosse aortique.
format article
author R. Scott McClure, MD
Kenton L. Rommens, MD
Eric J. Herget, MD
Oliver Halliwell, MD
Randy D. Moore, MD
author_facet R. Scott McClure, MD
Kenton L. Rommens, MD
Eric J. Herget, MD
Oliver Halliwell, MD
Randy D. Moore, MD
author_sort R. Scott McClure, MD
title Zone 0 Aortic Arch Reconstruction Using the RelayBranch Thoracic Stent Graft
title_short Zone 0 Aortic Arch Reconstruction Using the RelayBranch Thoracic Stent Graft
title_full Zone 0 Aortic Arch Reconstruction Using the RelayBranch Thoracic Stent Graft
title_fullStr Zone 0 Aortic Arch Reconstruction Using the RelayBranch Thoracic Stent Graft
title_full_unstemmed Zone 0 Aortic Arch Reconstruction Using the RelayBranch Thoracic Stent Graft
title_sort zone 0 aortic arch reconstruction using the relaybranch thoracic stent graft
publisher Elsevier
publishDate 2021
url https://doaj.org/article/ff35b9301ea345e3985d5bd571ea8586
work_keys_str_mv AT rscottmccluremd zone0aorticarchreconstructionusingtherelaybranchthoracicstentgraft
AT kentonlrommensmd zone0aorticarchreconstructionusingtherelaybranchthoracicstentgraft
AT ericjhergetmd zone0aorticarchreconstructionusingtherelaybranchthoracicstentgraft
AT oliverhalliwellmd zone0aorticarchreconstructionusingtherelaybranchthoracicstentgraft
AT randydmooremd zone0aorticarchreconstructionusingtherelaybranchthoracicstentgraft
_version_ 1718409880255070208