Application of cardiovascular virtual endoscopy: a pilot study on roaming path planning for diagnosis of congenital heart diseases in children
Abstract To investigate roaming paths planning for diagnosis of congenital heart diseases (CHD) using a cardiovascular virtual endoscopy (VE) system. Forty children were enrolled. VE system was applied to support in establishing a diagnosis. Performance in diagnosing CHDs by CT, VE using automatical...
Guardado en:
Autores principales: | , , , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2018
|
Materias: | |
Acceso en línea: | https://doaj.org/article/ffa54e84144744438621af7f08822e78 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:ffa54e84144744438621af7f08822e78 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:ffa54e84144744438621af7f08822e782021-12-02T15:09:05ZApplication of cardiovascular virtual endoscopy: a pilot study on roaming path planning for diagnosis of congenital heart diseases in children10.1038/s41598-017-16420-32045-2322https://doaj.org/article/ffa54e84144744438621af7f08822e782018-01-01T00:00:00Zhttps://doi.org/10.1038/s41598-017-16420-3https://doaj.org/toc/2045-2322Abstract To investigate roaming paths planning for diagnosis of congenital heart diseases (CHD) using a cardiovascular virtual endoscopy (VE) system. Forty children were enrolled. VE system was applied to support in establishing a diagnosis. Performance in diagnosing CHDs by CT, VE using automatically planned roaming paths (VE-auto, objects were treated as left heart system and right heart system), VE using manually planned paths (VE-manual), and VE using automatically planned path for left heart system and manually planned path for right heart system (VE-combined) were studied and compared. Comparable accuracy of 93%, 93%, 95% and 95% was found by CT, VE-auto, VE-manual and VE-combined. However, in diagnosing tetralogy of Fallot, significantly higher performance was found by VEs, compared with CT. For VE-auto, poor performance with an accuracy of 85% and sensitivity of 22% was revealed in diagnosing muscular ventricular septal defect, compared with VE-manual and VE-combined. Compared with VE-manual, VE-combined illustrated comparable diagnostic accuracy on all CHDs; however, significantly smaller diagnostic time was utilized (P < 0.05).Cardiovascular VE system demonstrated considerable clinical value in the diagnosis of CHDs. Left and right heart system should not be modeled as two cavity objects simultaneously. When one of two systems is treated as one object, the other system should be treated as three separate objects when using VE to diagnose CHDs.Li-Ping YaoJu MeiFang-Bao DingLi ZhangHui-Ming LiMing DingXin YangXiao-Ming LiKun SunNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 8, Iss 1, Pp 1-7 (2018) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Li-Ping Yao Ju Mei Fang-Bao Ding Li Zhang Hui-Ming Li Ming Ding Xin Yang Xiao-Ming Li Kun Sun Application of cardiovascular virtual endoscopy: a pilot study on roaming path planning for diagnosis of congenital heart diseases in children |
description |
Abstract To investigate roaming paths planning for diagnosis of congenital heart diseases (CHD) using a cardiovascular virtual endoscopy (VE) system. Forty children were enrolled. VE system was applied to support in establishing a diagnosis. Performance in diagnosing CHDs by CT, VE using automatically planned roaming paths (VE-auto, objects were treated as left heart system and right heart system), VE using manually planned paths (VE-manual), and VE using automatically planned path for left heart system and manually planned path for right heart system (VE-combined) were studied and compared. Comparable accuracy of 93%, 93%, 95% and 95% was found by CT, VE-auto, VE-manual and VE-combined. However, in diagnosing tetralogy of Fallot, significantly higher performance was found by VEs, compared with CT. For VE-auto, poor performance with an accuracy of 85% and sensitivity of 22% was revealed in diagnosing muscular ventricular septal defect, compared with VE-manual and VE-combined. Compared with VE-manual, VE-combined illustrated comparable diagnostic accuracy on all CHDs; however, significantly smaller diagnostic time was utilized (P < 0.05).Cardiovascular VE system demonstrated considerable clinical value in the diagnosis of CHDs. Left and right heart system should not be modeled as two cavity objects simultaneously. When one of two systems is treated as one object, the other system should be treated as three separate objects when using VE to diagnose CHDs. |
format |
article |
author |
Li-Ping Yao Ju Mei Fang-Bao Ding Li Zhang Hui-Ming Li Ming Ding Xin Yang Xiao-Ming Li Kun Sun |
author_facet |
Li-Ping Yao Ju Mei Fang-Bao Ding Li Zhang Hui-Ming Li Ming Ding Xin Yang Xiao-Ming Li Kun Sun |
author_sort |
Li-Ping Yao |
title |
Application of cardiovascular virtual endoscopy: a pilot study on roaming path planning for diagnosis of congenital heart diseases in children |
title_short |
Application of cardiovascular virtual endoscopy: a pilot study on roaming path planning for diagnosis of congenital heart diseases in children |
title_full |
Application of cardiovascular virtual endoscopy: a pilot study on roaming path planning for diagnosis of congenital heart diseases in children |
title_fullStr |
Application of cardiovascular virtual endoscopy: a pilot study on roaming path planning for diagnosis of congenital heart diseases in children |
title_full_unstemmed |
Application of cardiovascular virtual endoscopy: a pilot study on roaming path planning for diagnosis of congenital heart diseases in children |
title_sort |
application of cardiovascular virtual endoscopy: a pilot study on roaming path planning for diagnosis of congenital heart diseases in children |
publisher |
Nature Portfolio |
publishDate |
2018 |
url |
https://doaj.org/article/ffa54e84144744438621af7f08822e78 |
work_keys_str_mv |
AT lipingyao applicationofcardiovascularvirtualendoscopyapilotstudyonroamingpathplanningfordiagnosisofcongenitalheartdiseasesinchildren AT jumei applicationofcardiovascularvirtualendoscopyapilotstudyonroamingpathplanningfordiagnosisofcongenitalheartdiseasesinchildren AT fangbaoding applicationofcardiovascularvirtualendoscopyapilotstudyonroamingpathplanningfordiagnosisofcongenitalheartdiseasesinchildren AT lizhang applicationofcardiovascularvirtualendoscopyapilotstudyonroamingpathplanningfordiagnosisofcongenitalheartdiseasesinchildren AT huimingli applicationofcardiovascularvirtualendoscopyapilotstudyonroamingpathplanningfordiagnosisofcongenitalheartdiseasesinchildren AT mingding applicationofcardiovascularvirtualendoscopyapilotstudyonroamingpathplanningfordiagnosisofcongenitalheartdiseasesinchildren AT xinyang applicationofcardiovascularvirtualendoscopyapilotstudyonroamingpathplanningfordiagnosisofcongenitalheartdiseasesinchildren AT xiaomingli applicationofcardiovascularvirtualendoscopyapilotstudyonroamingpathplanningfordiagnosisofcongenitalheartdiseasesinchildren AT kunsun applicationofcardiovascularvirtualendoscopyapilotstudyonroamingpathplanningfordiagnosisofcongenitalheartdiseasesinchildren |
_version_ |
1718387978041032704 |