A pilot study: development of bonepreserving- biomimetic artificial femoral head cover
Patients with hip arthrosis are increasing each year where total hip replacement is an effective solution when other non-invasive or surgical methods are no longer an effective solution. A pilot study of a new bone-preserving-biomimetic artificial femoral head cover was initiated. The purpose of the...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
De Gruyter
2020
|
Materias: | |
Acceso en línea: | https://doaj.org/article/ffadeac2f5e843bf99821f990a08c6db |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:ffadeac2f5e843bf99821f990a08c6db |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:ffadeac2f5e843bf99821f990a08c6db2021-12-05T14:10:42ZA pilot study: development of bonepreserving- biomimetic artificial femoral head cover2364-550410.1515/cdbme-2020-3057https://doaj.org/article/ffadeac2f5e843bf99821f990a08c6db2020-09-01T00:00:00Zhttps://doi.org/10.1515/cdbme-2020-3057https://doaj.org/toc/2364-5504Patients with hip arthrosis are increasing each year where total hip replacement is an effective solution when other non-invasive or surgical methods are no longer an effective solution. A pilot study of a new bone-preserving-biomimetic artificial femoral head cover was initiated. The purpose of the new implant is to be an alternative to the current hip arthroplasties. A special polyurethane (PU) femoral head cover was mechanically tested. Experiments were performed to investigate the implants mechanical behaviour and response to tensile load and study on the locking mechanism design concept of the prosthesis. The femoral head cover had a 45 mm outer diameter. Two suture techniques were selected to represent possible locking mechanisms. The experiment consisted of five cyclic loadings followed by a pull-to-failure test. The results show that each specimen has a consistency response and different suture technique results in a different outcome. This experiment intended to study the response of specimens as a whole part, not the material itself. Factors are influencing the outcome such as the femoral head cover positioning and suture rupture pattern. From this pilot study, some points need to be further considered. The information obtained in this experiment would influence further development achieving towards the goal of this alternative hip arthrosis treatment.Siroros NadLiu YuLecouturier SophieTingart MarkusEschweiler JörgDe Gruyterarticlehip arthroplastyhip prosthesisfemoral head prosthesisMedicineRENCurrent Directions in Biomedical Engineering, Vol 6, Iss 3, Pp 225-228 (2020) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
hip arthroplasty hip prosthesis femoral head prosthesis Medicine R |
spellingShingle |
hip arthroplasty hip prosthesis femoral head prosthesis Medicine R Siroros Nad Liu Yu Lecouturier Sophie Tingart Markus Eschweiler Jörg A pilot study: development of bonepreserving- biomimetic artificial femoral head cover |
description |
Patients with hip arthrosis are increasing each year where total hip replacement is an effective solution when other non-invasive or surgical methods are no longer an effective solution. A pilot study of a new bone-preserving-biomimetic artificial femoral head cover was initiated. The purpose of the new implant is to be an alternative to the current hip arthroplasties. A special polyurethane (PU) femoral head cover was mechanically tested. Experiments were performed to investigate the implants mechanical behaviour and response to tensile load and study on the locking mechanism design concept of the prosthesis. The femoral head cover had a 45 mm outer diameter. Two suture techniques were selected to represent possible locking mechanisms. The experiment consisted of five cyclic loadings followed by a pull-to-failure test. The results show that each specimen has a consistency response and different suture technique results in a different outcome. This experiment intended to study the response of specimens as a whole part, not the material itself. Factors are influencing the outcome such as the femoral head cover positioning and suture rupture pattern. From this pilot study, some points need to be further considered. The information obtained in this experiment would influence further development achieving towards the goal of this alternative hip arthrosis treatment. |
format |
article |
author |
Siroros Nad Liu Yu Lecouturier Sophie Tingart Markus Eschweiler Jörg |
author_facet |
Siroros Nad Liu Yu Lecouturier Sophie Tingart Markus Eschweiler Jörg |
author_sort |
Siroros Nad |
title |
A pilot study: development of bonepreserving- biomimetic artificial femoral head cover |
title_short |
A pilot study: development of bonepreserving- biomimetic artificial femoral head cover |
title_full |
A pilot study: development of bonepreserving- biomimetic artificial femoral head cover |
title_fullStr |
A pilot study: development of bonepreserving- biomimetic artificial femoral head cover |
title_full_unstemmed |
A pilot study: development of bonepreserving- biomimetic artificial femoral head cover |
title_sort |
pilot study: development of bonepreserving- biomimetic artificial femoral head cover |
publisher |
De Gruyter |
publishDate |
2020 |
url |
https://doaj.org/article/ffadeac2f5e843bf99821f990a08c6db |
work_keys_str_mv |
AT sirorosnad apilotstudydevelopmentofbonepreservingbiomimeticartificialfemoralheadcover AT liuyu apilotstudydevelopmentofbonepreservingbiomimeticartificialfemoralheadcover AT lecouturiersophie apilotstudydevelopmentofbonepreservingbiomimeticartificialfemoralheadcover AT tingartmarkus apilotstudydevelopmentofbonepreservingbiomimeticartificialfemoralheadcover AT eschweilerjorg apilotstudydevelopmentofbonepreservingbiomimeticartificialfemoralheadcover AT sirorosnad pilotstudydevelopmentofbonepreservingbiomimeticartificialfemoralheadcover AT liuyu pilotstudydevelopmentofbonepreservingbiomimeticartificialfemoralheadcover AT lecouturiersophie pilotstudydevelopmentofbonepreservingbiomimeticartificialfemoralheadcover AT tingartmarkus pilotstudydevelopmentofbonepreservingbiomimeticartificialfemoralheadcover AT eschweilerjorg pilotstudydevelopmentofbonepreservingbiomimeticartificialfemoralheadcover |
_version_ |
1718371818304176128 |