High seebeck coefficient in middle-temperature thermocell with deep eutectic solvent

Abstract Deep eutectic solvent (DES) was applied to the solvent of thermocell and high Seebeck coefficient (S e) of the thermocell was achieved at high-temperatures operation. The S e of a redox couple of ferricyanide and ferrocyanide ([Fe(CN)6]3−/4−) reaches − 1.67 mV/K in a DES consisting of ethyl...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Naura Fakhira Antariksa, Teppei Yamada, Nobuo Kimizuka
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/ffd4d28b63fe497a84d1fa91f5e253d9
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:ffd4d28b63fe497a84d1fa91f5e253d9
record_format dspace
spelling oai:doaj.org-article:ffd4d28b63fe497a84d1fa91f5e253d92021-12-02T14:58:14ZHigh seebeck coefficient in middle-temperature thermocell with deep eutectic solvent10.1038/s41598-021-91419-52045-2322https://doaj.org/article/ffd4d28b63fe497a84d1fa91f5e253d92021-06-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-91419-5https://doaj.org/toc/2045-2322Abstract Deep eutectic solvent (DES) was applied to the solvent of thermocell and high Seebeck coefficient (S e) of the thermocell was achieved at high-temperatures operation. The S e of a redox couple of ferricyanide and ferrocyanide ([Fe(CN)6]3−/4−) reaches − 1.67 mV/K in a DES consisting of ethylene glycol and choline chloride. Spectroscopic analysis reveals that this is due to the strong interactions between the redox couple and the DES. Furthermore, the cell can operate over a wide temperature range of 135–165 °C. This result is a desired feature for waste-heat recovery applications.Naura Fakhira AntariksaTeppei YamadaNobuo KimizukaNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-7 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Naura Fakhira Antariksa
Teppei Yamada
Nobuo Kimizuka
High seebeck coefficient in middle-temperature thermocell with deep eutectic solvent
description Abstract Deep eutectic solvent (DES) was applied to the solvent of thermocell and high Seebeck coefficient (S e) of the thermocell was achieved at high-temperatures operation. The S e of a redox couple of ferricyanide and ferrocyanide ([Fe(CN)6]3−/4−) reaches − 1.67 mV/K in a DES consisting of ethylene glycol and choline chloride. Spectroscopic analysis reveals that this is due to the strong interactions between the redox couple and the DES. Furthermore, the cell can operate over a wide temperature range of 135–165 °C. This result is a desired feature for waste-heat recovery applications.
format article
author Naura Fakhira Antariksa
Teppei Yamada
Nobuo Kimizuka
author_facet Naura Fakhira Antariksa
Teppei Yamada
Nobuo Kimizuka
author_sort Naura Fakhira Antariksa
title High seebeck coefficient in middle-temperature thermocell with deep eutectic solvent
title_short High seebeck coefficient in middle-temperature thermocell with deep eutectic solvent
title_full High seebeck coefficient in middle-temperature thermocell with deep eutectic solvent
title_fullStr High seebeck coefficient in middle-temperature thermocell with deep eutectic solvent
title_full_unstemmed High seebeck coefficient in middle-temperature thermocell with deep eutectic solvent
title_sort high seebeck coefficient in middle-temperature thermocell with deep eutectic solvent
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/ffd4d28b63fe497a84d1fa91f5e253d9
work_keys_str_mv AT naurafakhiraantariksa highseebeckcoefficientinmiddletemperaturethermocellwithdeepeutecticsolvent
AT teppeiyamada highseebeckcoefficientinmiddletemperaturethermocellwithdeepeutecticsolvent
AT nobuokimizuka highseebeckcoefficientinmiddletemperaturethermocellwithdeepeutecticsolvent
_version_ 1718389363735265280