Hipercoagulabilidad en fibrilación auricular y su relación con factores de riesgo para embolia sistémica
Background: Atrial fibrillation is associated to a high risk of systemic embolism and to hypercoagulability. Aim: To evaluate the activation of the coagulation cascade through determinations of the thrombin-antithrombin complex in patients with atrial fibrillation and to correlate this data with the...
Guardado en:
Autores principales: | , , , , , , , , , , |
---|---|
Lenguaje: | Spanish / Castilian |
Publicado: |
Sociedad Médica de Santiago
2002
|
Materias: | |
Acceso en línea: | http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872002001000002 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:scielo:S0034-98872002001000002 |
---|---|
record_format |
dspace |
spelling |
oai:scielo:S0034-988720020010000022014-08-21Hipercoagulabilidad en fibrilación auricular y su relación con factores de riesgo para embolia sistémicaPérez P,Luis ACorbalán H,RamónAcevedo B,MónicaPereira,JaimeBraun J,SandraTapia I,JorgeKramer Sch,AlbrechtLira C,Mª TeresaHuete,IsidroSepúlveda,GonzaloSpringmüller,Daniel Arrhythmia Atrial fibrillation Coagulation protein disorders Embolism and thrombosis Background: Atrial fibrillation is associated to a high risk of systemic embolism and to hypercoagulability. Aim: To evaluate the activation of the coagulation cascade through determinations of the thrombin-antithrombin complex in patients with atrial fibrillation and to correlate this data with the clinical and echocardiographic risk factors for systemic embolism. Patients and Methods: In 53 patients with atrial fibrillation plasma levels of the thrombin-antithrombin complex were determined on admission to a coronary care unit and 30 days later. Using a univariate and multiple regression analysis, the association basal thrombin-antithrombin with the duration of the arrhythmia, age over 70 years, previous use of antiplatelet agents, history of hypertension, mitral valve disease, diabetes, heart failure, previous systemic embolism, left atrial diameter and the presence of spontaneous contrast echo or thrombus in the left atrial appendage, was studied. Results: Basal thrombin-antithrombin values were 40.1±69 mg/L (Median 8.34 [3.0-47.5]) compared to 2.7±3.3 mg/L in healthy controls (p <0.001). No significant correlation was found between activation of the coagulation cascade and risk factors for systemic embolism. There were no significant differences in thrombin-antithrombin values between patients with chronic or paroxysmal atrial fibrillation (29.5±43 mg/L and 49.4±83 mg/L respectively). Mean thrombin-antithrombin values in patients under antiplatelet agents were lower than in those without treatment (17.3±43 vs 66.8±127 mg/L; p=0.018). Conclusions: The activation of the coagulation cascade in patients with atrial fibrillation was confirmed. However, no association of this activation with well known clinical and echocardiographic risk factors for systemic embolism, was found. Previous antiplatelet treatment prevented a higher activation of the coagulation cascade (Rev Méd Chile 2002; 130: 1087-94)info:eu-repo/semantics/openAccessSociedad Médica de SantiagoRevista médica de Chile v.130 n.10 20022002-10-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872002001000002es10.4067/S0034-98872002001000002 |
institution |
Scielo Chile |
collection |
Scielo Chile |
language |
Spanish / Castilian |
topic |
Arrhythmia Atrial fibrillation Coagulation protein disorders Embolism and thrombosis |
spellingShingle |
Arrhythmia Atrial fibrillation Coagulation protein disorders Embolism and thrombosis Pérez P,Luis A Corbalán H,Ramón Acevedo B,Mónica Pereira,Jaime Braun J,Sandra Tapia I,Jorge Kramer Sch,Albrecht Lira C,Mª Teresa Huete,Isidro Sepúlveda,Gonzalo Springmüller,Daniel Hipercoagulabilidad en fibrilación auricular y su relación con factores de riesgo para embolia sistémica |
description |
Background: Atrial fibrillation is associated to a high risk of systemic embolism and to hypercoagulability. Aim: To evaluate the activation of the coagulation cascade through determinations of the thrombin-antithrombin complex in patients with atrial fibrillation and to correlate this data with the clinical and echocardiographic risk factors for systemic embolism. Patients and Methods: In 53 patients with atrial fibrillation plasma levels of the thrombin-antithrombin complex were determined on admission to a coronary care unit and 30 days later. Using a univariate and multiple regression analysis, the association basal thrombin-antithrombin with the duration of the arrhythmia, age over 70 years, previous use of antiplatelet agents, history of hypertension, mitral valve disease, diabetes, heart failure, previous systemic embolism, left atrial diameter and the presence of spontaneous contrast echo or thrombus in the left atrial appendage, was studied. Results: Basal thrombin-antithrombin values were 40.1±69 mg/L (Median 8.34 [3.0-47.5]) compared to 2.7±3.3 mg/L in healthy controls (p <0.001). No significant correlation was found between activation of the coagulation cascade and risk factors for systemic embolism. There were no significant differences in thrombin-antithrombin values between patients with chronic or paroxysmal atrial fibrillation (29.5±43 mg/L and 49.4±83 mg/L respectively). Mean thrombin-antithrombin values in patients under antiplatelet agents were lower than in those without treatment (17.3±43 vs 66.8±127 mg/L; p=0.018). Conclusions: The activation of the coagulation cascade in patients with atrial fibrillation was confirmed. However, no association of this activation with well known clinical and echocardiographic risk factors for systemic embolism, was found. Previous antiplatelet treatment prevented a higher activation of the coagulation cascade (Rev Méd Chile 2002; 130: 1087-94) |
author |
Pérez P,Luis A Corbalán H,Ramón Acevedo B,Mónica Pereira,Jaime Braun J,Sandra Tapia I,Jorge Kramer Sch,Albrecht Lira C,Mª Teresa Huete,Isidro Sepúlveda,Gonzalo Springmüller,Daniel |
author_facet |
Pérez P,Luis A Corbalán H,Ramón Acevedo B,Mónica Pereira,Jaime Braun J,Sandra Tapia I,Jorge Kramer Sch,Albrecht Lira C,Mª Teresa Huete,Isidro Sepúlveda,Gonzalo Springmüller,Daniel |
author_sort |
Pérez P,Luis A |
title |
Hipercoagulabilidad en fibrilación auricular y su relación con factores de riesgo para embolia sistémica |
title_short |
Hipercoagulabilidad en fibrilación auricular y su relación con factores de riesgo para embolia sistémica |
title_full |
Hipercoagulabilidad en fibrilación auricular y su relación con factores de riesgo para embolia sistémica |
title_fullStr |
Hipercoagulabilidad en fibrilación auricular y su relación con factores de riesgo para embolia sistémica |
title_full_unstemmed |
Hipercoagulabilidad en fibrilación auricular y su relación con factores de riesgo para embolia sistémica |
title_sort |
hipercoagulabilidad en fibrilación auricular y su relación con factores de riesgo para embolia sistémica |
publisher |
Sociedad Médica de Santiago |
publishDate |
2002 |
url |
http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872002001000002 |
work_keys_str_mv |
AT perezpluisa hipercoagulabilidadenfibrilacionauricularysurelacionconfactoresderiesgoparaemboliasistemica AT corbalanhramon hipercoagulabilidadenfibrilacionauricularysurelacionconfactoresderiesgoparaemboliasistemica AT acevedobmonica hipercoagulabilidadenfibrilacionauricularysurelacionconfactoresderiesgoparaemboliasistemica AT pereirajaime hipercoagulabilidadenfibrilacionauricularysurelacionconfactoresderiesgoparaemboliasistemica AT braunjsandra hipercoagulabilidadenfibrilacionauricularysurelacionconfactoresderiesgoparaemboliasistemica AT tapiaijorge hipercoagulabilidadenfibrilacionauricularysurelacionconfactoresderiesgoparaemboliasistemica AT kramerschalbrecht hipercoagulabilidadenfibrilacionauricularysurelacionconfactoresderiesgoparaemboliasistemica AT liracmateresa hipercoagulabilidadenfibrilacionauricularysurelacionconfactoresderiesgoparaemboliasistemica AT hueteisidro hipercoagulabilidadenfibrilacionauricularysurelacionconfactoresderiesgoparaemboliasistemica AT sepulvedagonzalo hipercoagulabilidadenfibrilacionauricularysurelacionconfactoresderiesgoparaemboliasistemica AT springmullerdaniel hipercoagulabilidadenfibrilacionauricularysurelacionconfactoresderiesgoparaemboliasistemica |
_version_ |
1718436059497365504 |