Síndrome cardiopulmonar por Hantavirus: utilidad de la monitorización con el sistema PiCCO

We report a 68 years old man, farmer from the metropolitan region, admitted with a Hantavirus Cardiopulmonary Syndrome. The diagnosis was made using serologic test and was later confirmed by the Public Health Institute. He evolved to an early multiple organ failure, requiring high concentrations of...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Romero P,Carlos, Andresen H,Max, Díaz P,Orlando, Tomicic F,Vinko, Baraona R,Fernando, Mercado F,Marcelo, Pérez C,Carlos, Downey C,Patricio, Dougnac L,Alberto
Lenguaje:Spanish / Castilian
Publicado: Sociedad Médica de Santiago 2003
Materias:
Acceso en línea:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872003001000011
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:scielo:S0034-98872003001000011
record_format dspace
spelling oai:scielo:S0034-988720030010000112004-12-07Síndrome cardiopulmonar por Hantavirus: utilidad de la monitorización con el sistema PiCCORomero P,CarlosAndresen H,MaxDíaz P,OrlandoTomicic F,VinkoBaraona R,FernandoMercado F,MarceloPérez C,CarlosDowney C,PatricioDougnac L,Alberto Cardiac output Hantavirus pulmonary syndrome Multiple organ failure We report a 68 years old man, farmer from the metropolitan region, admitted with a Hantavirus Cardiopulmonary Syndrome. The diagnosis was made using serologic test and was later confirmed by the Public Health Institute. He evolved to an early multiple organ failure, requiring high concentrations of oxygen and invasive ventilatory assistance, vasopressor drugs and renal replacement therapy. Swan Ganz and PiCCO were used simultaneously for hemodynamic monitoring. Treatment consisted in global support therapy, antimicrobial therapy and systemic corticosteroids. Intrathoracic blood volume was a more reliable parameter than pulmonary capillary wedge pressure for the assessment of preload. As expected in situations of increased vascular permeability, there was an increase in extravascular lung water. There was a good correlation between extravascular lung water and oxygenation parameters (PaO2/FiO2 and oxygenation index). PiCCO system may become a helpful tool in the management of patients with Hantavirus Cardiopulmonary Syndrome (Rev Méd Chile 2003; 131: 1173-78)info:eu-repo/semantics/openAccessSociedad Médica de SantiagoRevista médica de Chile v.131 n.10 20032003-10-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872003001000011es10.4067/S0034-98872003001000011
institution Scielo Chile
collection Scielo Chile
language Spanish / Castilian
topic Cardiac output
Hantavirus pulmonary syndrome
Multiple organ failure
spellingShingle Cardiac output
Hantavirus pulmonary syndrome
Multiple organ failure
Romero P,Carlos
Andresen H,Max
Díaz P,Orlando
Tomicic F,Vinko
Baraona R,Fernando
Mercado F,Marcelo
Pérez C,Carlos
Downey C,Patricio
Dougnac L,Alberto
Síndrome cardiopulmonar por Hantavirus: utilidad de la monitorización con el sistema PiCCO
description We report a 68 years old man, farmer from the metropolitan region, admitted with a Hantavirus Cardiopulmonary Syndrome. The diagnosis was made using serologic test and was later confirmed by the Public Health Institute. He evolved to an early multiple organ failure, requiring high concentrations of oxygen and invasive ventilatory assistance, vasopressor drugs and renal replacement therapy. Swan Ganz and PiCCO were used simultaneously for hemodynamic monitoring. Treatment consisted in global support therapy, antimicrobial therapy and systemic corticosteroids. Intrathoracic blood volume was a more reliable parameter than pulmonary capillary wedge pressure for the assessment of preload. As expected in situations of increased vascular permeability, there was an increase in extravascular lung water. There was a good correlation between extravascular lung water and oxygenation parameters (PaO2/FiO2 and oxygenation index). PiCCO system may become a helpful tool in the management of patients with Hantavirus Cardiopulmonary Syndrome (Rev Méd Chile 2003; 131: 1173-78)
author Romero P,Carlos
Andresen H,Max
Díaz P,Orlando
Tomicic F,Vinko
Baraona R,Fernando
Mercado F,Marcelo
Pérez C,Carlos
Downey C,Patricio
Dougnac L,Alberto
author_facet Romero P,Carlos
Andresen H,Max
Díaz P,Orlando
Tomicic F,Vinko
Baraona R,Fernando
Mercado F,Marcelo
Pérez C,Carlos
Downey C,Patricio
Dougnac L,Alberto
author_sort Romero P,Carlos
title Síndrome cardiopulmonar por Hantavirus: utilidad de la monitorización con el sistema PiCCO
title_short Síndrome cardiopulmonar por Hantavirus: utilidad de la monitorización con el sistema PiCCO
title_full Síndrome cardiopulmonar por Hantavirus: utilidad de la monitorización con el sistema PiCCO
title_fullStr Síndrome cardiopulmonar por Hantavirus: utilidad de la monitorización con el sistema PiCCO
title_full_unstemmed Síndrome cardiopulmonar por Hantavirus: utilidad de la monitorización con el sistema PiCCO
title_sort síndrome cardiopulmonar por hantavirus: utilidad de la monitorización con el sistema picco
publisher Sociedad Médica de Santiago
publishDate 2003
url http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872003001000011
work_keys_str_mv AT romeropcarlos sindromecardiopulmonarporhantavirusutilidaddelamonitorizacionconelsistemapicco
AT andresenhmax sindromecardiopulmonarporhantavirusutilidaddelamonitorizacionconelsistemapicco
AT diazporlando sindromecardiopulmonarporhantavirusutilidaddelamonitorizacionconelsistemapicco
AT tomicicfvinko sindromecardiopulmonarporhantavirusutilidaddelamonitorizacionconelsistemapicco
AT baraonarfernando sindromecardiopulmonarporhantavirusutilidaddelamonitorizacionconelsistemapicco
AT mercadofmarcelo sindromecardiopulmonarporhantavirusutilidaddelamonitorizacionconelsistemapicco
AT perezccarlos sindromecardiopulmonarporhantavirusutilidaddelamonitorizacionconelsistemapicco
AT downeycpatricio sindromecardiopulmonarporhantavirusutilidaddelamonitorizacionconelsistemapicco
AT dougnaclalberto sindromecardiopulmonarporhantavirusutilidaddelamonitorizacionconelsistemapicco
_version_ 1718436117133393920