Experiencia en el uso de un nuevo catéter electrodo de estimulación endocavitaria: Seguimiento a un año
Background: Since February 2002, Flextend® electrode catheters are used at the Cardiovascular Unit of the Catholic University Clinical Hospital. These transvenous catheters have an IS-1 connector, silicone coating, active fixation and retractile helix with dexamethasone acetate. Aim: To report early...
Guardado en:
Autores principales: | , , , , |
---|---|
Lenguaje: | Spanish / Castilian |
Publicado: |
Sociedad Médica de Santiago
2006
|
Materias: | |
Acceso en línea: | http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872006000600011 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:scielo:S0034-98872006000600011 |
---|---|
record_format |
dspace |
spelling |
oai:scielo:S0034-988720060006000112006-08-14Experiencia en el uso de un nuevo catéter electrodo de estimulación endocavitaria: Seguimiento a un añoFrangini S,PatriciaVergara S,IsmaelGonzález A,RolandoBaeza L,MarianaCambón R,Ana María Pacemaker artificial Electrodos, immplanted Background: Since February 2002, Flextend® electrode catheters are used at the Cardiovascular Unit of the Catholic University Clinical Hospital. These transvenous catheters have an IS-1 connector, silicone coating, active fixation and retractile helix with dexamethasone acetate. Aim: To report early and one year results using Flextend® catheters. Material and methods: Retrospective analysis of all patients that received an implant of a Flextend® catheter in the Unit. Results: Forty one Flextend® catheters were implanted in 24 patients, without acute displacement or clinical pericarditis. In 18 electrode catheters located in the right atrium the mean values for p wave, stimulation threshold and impedance at the moment of placement, were 2.9±1.4 mV, 0.8±0.4 V and 522±86 Ohms, respectively. The figures 24 hours after placement were 3.6±2.1 mV, 0.8±0.3 V and 612±69 Ohms, respectively. In 23 electrode catheters in the right ventricle, mean values at the moment of placement for R wave, stimulation threshold and impedance were 11.3±3.6 mV, 0.8±0.2 V and 756±108 Ohms, respectively. The figures 24 hours after placement were 3.6±2.1 mV, 0.8±0.3 V and 612±69 Ohms, respectively. In one patient, the stimulation threshold increased two months after placement and required a new intervention. Conclusions: Flextend® catheters ca be placed successfully with a low rate of complications and stable function parameters on follow upinfo:eu-repo/semantics/openAccessSociedad Médica de SantiagoRevista médica de Chile v.134 n.6 20062006-06-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872006000600011es10.4067/S0034-98872006000600011 |
institution |
Scielo Chile |
collection |
Scielo Chile |
language |
Spanish / Castilian |
topic |
Pacemaker artificial Electrodos, immplanted |
spellingShingle |
Pacemaker artificial Electrodos, immplanted Frangini S,Patricia Vergara S,Ismael González A,Rolando Baeza L,Mariana Cambón R,Ana María Experiencia en el uso de un nuevo catéter electrodo de estimulación endocavitaria: Seguimiento a un año |
description |
Background: Since February 2002, Flextend® electrode catheters are used at the Cardiovascular Unit of the Catholic University Clinical Hospital. These transvenous catheters have an IS-1 connector, silicone coating, active fixation and retractile helix with dexamethasone acetate. Aim: To report early and one year results using Flextend® catheters. Material and methods: Retrospective analysis of all patients that received an implant of a Flextend® catheter in the Unit. Results: Forty one Flextend® catheters were implanted in 24 patients, without acute displacement or clinical pericarditis. In 18 electrode catheters located in the right atrium the mean values for p wave, stimulation threshold and impedance at the moment of placement, were 2.9±1.4 mV, 0.8±0.4 V and 522±86 Ohms, respectively. The figures 24 hours after placement were 3.6±2.1 mV, 0.8±0.3 V and 612±69 Ohms, respectively. In 23 electrode catheters in the right ventricle, mean values at the moment of placement for R wave, stimulation threshold and impedance were 11.3±3.6 mV, 0.8±0.2 V and 756±108 Ohms, respectively. The figures 24 hours after placement were 3.6±2.1 mV, 0.8±0.3 V and 612±69 Ohms, respectively. In one patient, the stimulation threshold increased two months after placement and required a new intervention. Conclusions: Flextend® catheters ca be placed successfully with a low rate of complications and stable function parameters on follow up |
author |
Frangini S,Patricia Vergara S,Ismael González A,Rolando Baeza L,Mariana Cambón R,Ana María |
author_facet |
Frangini S,Patricia Vergara S,Ismael González A,Rolando Baeza L,Mariana Cambón R,Ana María |
author_sort |
Frangini S,Patricia |
title |
Experiencia en el uso de un nuevo catéter electrodo de estimulación endocavitaria: Seguimiento a un año |
title_short |
Experiencia en el uso de un nuevo catéter electrodo de estimulación endocavitaria: Seguimiento a un año |
title_full |
Experiencia en el uso de un nuevo catéter electrodo de estimulación endocavitaria: Seguimiento a un año |
title_fullStr |
Experiencia en el uso de un nuevo catéter electrodo de estimulación endocavitaria: Seguimiento a un año |
title_full_unstemmed |
Experiencia en el uso de un nuevo catéter electrodo de estimulación endocavitaria: Seguimiento a un año |
title_sort |
experiencia en el uso de un nuevo catéter electrodo de estimulación endocavitaria: seguimiento a un año |
publisher |
Sociedad Médica de Santiago |
publishDate |
2006 |
url |
http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872006000600011 |
work_keys_str_mv |
AT franginispatricia experienciaenelusodeunnuevocateterelectrododeestimulacionendocavitariaseguimientoaunano AT vergarasismael experienciaenelusodeunnuevocateterelectrododeestimulacionendocavitariaseguimientoaunano AT gonzalezarolando experienciaenelusodeunnuevocateterelectrododeestimulacionendocavitariaseguimientoaunano AT baezalmariana experienciaenelusodeunnuevocateterelectrododeestimulacionendocavitariaseguimientoaunano AT cambonranamaria experienciaenelusodeunnuevocateterelectrododeestimulacionendocavitariaseguimientoaunano |
_version_ |
1718436266188472320 |