Uso del dispositivo de asistencia respiratoria Novalung® como puente a trasplante pulmonar: Caso clínico

Devices such as Novalung® can be used as a bridge to lung transplantation while waiting for a suitable donor. We report a 50 year-old male with a terminal pulmonary fibrosis and candidate for lung transplantation. He was admitted to the hospital due to a severe deterioration of his respiratory condi...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Fernández,Patricio, Muñoz,Pablo, Fischer,Danilo, Méndez,Felipe, Florenzano,Matías, Valdés,Sergio, Parada,María Teresa, Fica,Mauricio, Rodríguez,Patricio, Díaz,Rodrigo, Rufs,Jorge
Lenguaje:Spanish / Castilian
Publicado: Sociedad Médica de Santiago 2009
Materias:
Acceso en línea:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872009001000013
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:scielo:S0034-98872009001000013
record_format dspace
spelling oai:scielo:S0034-988720090010000132009-12-02Uso del dispositivo de asistencia respiratoria Novalung® como puente a trasplante pulmonar: Caso clínicoFernández,PatricioMuñoz,PabloFischer,DaniloMéndez,FelipeFlorenzano,MatíasValdés,SergioParada,María TeresaFica,MauricioRodríguez,PatricioDíaz,RodrigoRufs,Jorge Lung assist device Lung transplantation Respiratory distress syndrome adult Devices such as Novalung® can be used as a bridge to lung transplantation while waiting for a suitable donor. We report a 50 year-old male with a terminal pulmonary fibrosis and candidate for lung transplantation. He was admitted to the hospital due to a severe deterioration of his respiratory condition, with the presence of severe respiratory acidosis despite conventional invasive respiratory support. Respiratory support with Novalung® was started, resulting in a progressive reduction ofpCOz that became normal ten hours after the installation of the device. Five days later a successful lung transplantation wasperformed.info:eu-repo/semantics/openAccessSociedad Médica de SantiagoRevista médica de Chile v.137 n.10 20092009-10-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872009001000013es10.4067/S0034-98872009001000013
institution Scielo Chile
collection Scielo Chile
language Spanish / Castilian
topic Lung assist device
Lung transplantation
Respiratory distress syndrome
adult
spellingShingle Lung assist device
Lung transplantation
Respiratory distress syndrome
adult
Fernández,Patricio
Muñoz,Pablo
Fischer,Danilo
Méndez,Felipe
Florenzano,Matías
Valdés,Sergio
Parada,María Teresa
Fica,Mauricio
Rodríguez,Patricio
Díaz,Rodrigo
Rufs,Jorge
Uso del dispositivo de asistencia respiratoria Novalung® como puente a trasplante pulmonar: Caso clínico
description Devices such as Novalung® can be used as a bridge to lung transplantation while waiting for a suitable donor. We report a 50 year-old male with a terminal pulmonary fibrosis and candidate for lung transplantation. He was admitted to the hospital due to a severe deterioration of his respiratory condition, with the presence of severe respiratory acidosis despite conventional invasive respiratory support. Respiratory support with Novalung® was started, resulting in a progressive reduction ofpCOz that became normal ten hours after the installation of the device. Five days later a successful lung transplantation wasperformed.
author Fernández,Patricio
Muñoz,Pablo
Fischer,Danilo
Méndez,Felipe
Florenzano,Matías
Valdés,Sergio
Parada,María Teresa
Fica,Mauricio
Rodríguez,Patricio
Díaz,Rodrigo
Rufs,Jorge
author_facet Fernández,Patricio
Muñoz,Pablo
Fischer,Danilo
Méndez,Felipe
Florenzano,Matías
Valdés,Sergio
Parada,María Teresa
Fica,Mauricio
Rodríguez,Patricio
Díaz,Rodrigo
Rufs,Jorge
author_sort Fernández,Patricio
title Uso del dispositivo de asistencia respiratoria Novalung® como puente a trasplante pulmonar: Caso clínico
title_short Uso del dispositivo de asistencia respiratoria Novalung® como puente a trasplante pulmonar: Caso clínico
title_full Uso del dispositivo de asistencia respiratoria Novalung® como puente a trasplante pulmonar: Caso clínico
title_fullStr Uso del dispositivo de asistencia respiratoria Novalung® como puente a trasplante pulmonar: Caso clínico
title_full_unstemmed Uso del dispositivo de asistencia respiratoria Novalung® como puente a trasplante pulmonar: Caso clínico
title_sort uso del dispositivo de asistencia respiratoria novalung® como puente a trasplante pulmonar: caso clínico
publisher Sociedad Médica de Santiago
publishDate 2009
url http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872009001000013
work_keys_str_mv AT fernandezpatricio usodeldispositivodeasistenciarespiratorianovalungcomopuenteatrasplantepulmonarcasoclinico
AT munozpablo usodeldispositivodeasistenciarespiratorianovalungcomopuenteatrasplantepulmonarcasoclinico
AT fischerdanilo usodeldispositivodeasistenciarespiratorianovalungcomopuenteatrasplantepulmonarcasoclinico
AT mendezfelipe usodeldispositivodeasistenciarespiratorianovalungcomopuenteatrasplantepulmonarcasoclinico
AT florenzanomatias usodeldispositivodeasistenciarespiratorianovalungcomopuenteatrasplantepulmonarcasoclinico
AT valdessergio usodeldispositivodeasistenciarespiratorianovalungcomopuenteatrasplantepulmonarcasoclinico
AT paradamariateresa usodeldispositivodeasistenciarespiratorianovalungcomopuenteatrasplantepulmonarcasoclinico
AT ficamauricio usodeldispositivodeasistenciarespiratorianovalungcomopuenteatrasplantepulmonarcasoclinico
AT rodriguezpatricio usodeldispositivodeasistenciarespiratorianovalungcomopuenteatrasplantepulmonarcasoclinico
AT diazrodrigo usodeldispositivodeasistenciarespiratorianovalungcomopuenteatrasplantepulmonarcasoclinico
AT rufsjorge usodeldispositivodeasistenciarespiratorianovalungcomopuenteatrasplantepulmonarcasoclinico
_version_ 1718436469908963328