La quemadura eléctrica por alto voltaje es un factor predictor de mortalidad en pacientes "grandes quemados"

Background: Electrical burns are associated with complications and may aggravate burned patients. Aim: To evaluate the effect of electrical burns in mortality and length of stay in a critical care unit for burn patients. Material and Methods: Retrospective analysis of medical records of 182 patients...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: MANGELSDORFF G,GÜNTHER, GARCÍA-HUIDOBRO D,M. ANGÉLICA, ATENAS M,OMAR, WHITTLE V,SANDRA, VILLEGAS C,JORGE
Lenguaje:Spanish / Castilian
Publicado: Sociedad Médica de Santiago 2011
Materias:
Acceso en línea:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872011000200006
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:scielo:S0034-98872011000200006
record_format dspace
spelling oai:scielo:S0034-988720110002000062011-08-01La quemadura eléctrica por alto voltaje es un factor predictor de mortalidad en pacientes "grandes quemados"MANGELSDORFF G,GÜNTHERGARCÍA-HUIDOBRO D,M. ANGÉLICAATENAS M,OMARWHITTLE V,SANDRAVILLEGAS C,JORGE Burns, electric Intensive care Wounds and injuries Background: Electrical burns are associated with complications and may aggravate burned patients. Aim: To evaluate the effect of electrical burns in mortality and length of stay in a critical care unit for burn patients. Material and Methods: Retrospective analysis of medical records of 182 patients aged 15 to 90 years, admitted to an intensive care unit for burn patients. The length of stay and mortality of 14 patients that suffered electric burns was compared with the features of 168 patients with other type of burns. Results: Patients with electrical burns were younger, had a lower percentage of total body surface burnt and had a lower frequency of inhalatory injuries than their counterparts with other type of burns. Mortality rate among patients with electric or other types of burns was similar (three and 49 patients, respectively). Intensive care unit stay was also similar. A multivariate analysis showed that high voltage electric burns were an independent risk factor for death with an odds ratio of 12 (95% confidence intervals 1.8-79.4). Conclusions: High voltage electric burns are an independent risk factor for death among burn patients.info:eu-repo/semantics/openAccessSociedad Médica de SantiagoRevista médica de Chile v.139 n.2 20112011-02-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872011000200006es10.4067/S0034-98872011000200006
institution Scielo Chile
collection Scielo Chile
language Spanish / Castilian
topic Burns, electric
Intensive care
Wounds and injuries
spellingShingle Burns, electric
Intensive care
Wounds and injuries
MANGELSDORFF G,GÜNTHER
GARCÍA-HUIDOBRO D,M. ANGÉLICA
ATENAS M,OMAR
WHITTLE V,SANDRA
VILLEGAS C,JORGE
La quemadura eléctrica por alto voltaje es un factor predictor de mortalidad en pacientes "grandes quemados"
description Background: Electrical burns are associated with complications and may aggravate burned patients. Aim: To evaluate the effect of electrical burns in mortality and length of stay in a critical care unit for burn patients. Material and Methods: Retrospective analysis of medical records of 182 patients aged 15 to 90 years, admitted to an intensive care unit for burn patients. The length of stay and mortality of 14 patients that suffered electric burns was compared with the features of 168 patients with other type of burns. Results: Patients with electrical burns were younger, had a lower percentage of total body surface burnt and had a lower frequency of inhalatory injuries than their counterparts with other type of burns. Mortality rate among patients with electric or other types of burns was similar (three and 49 patients, respectively). Intensive care unit stay was also similar. A multivariate analysis showed that high voltage electric burns were an independent risk factor for death with an odds ratio of 12 (95% confidence intervals 1.8-79.4). Conclusions: High voltage electric burns are an independent risk factor for death among burn patients.
author MANGELSDORFF G,GÜNTHER
GARCÍA-HUIDOBRO D,M. ANGÉLICA
ATENAS M,OMAR
WHITTLE V,SANDRA
VILLEGAS C,JORGE
author_facet MANGELSDORFF G,GÜNTHER
GARCÍA-HUIDOBRO D,M. ANGÉLICA
ATENAS M,OMAR
WHITTLE V,SANDRA
VILLEGAS C,JORGE
author_sort MANGELSDORFF G,GÜNTHER
title La quemadura eléctrica por alto voltaje es un factor predictor de mortalidad en pacientes "grandes quemados"
title_short La quemadura eléctrica por alto voltaje es un factor predictor de mortalidad en pacientes "grandes quemados"
title_full La quemadura eléctrica por alto voltaje es un factor predictor de mortalidad en pacientes "grandes quemados"
title_fullStr La quemadura eléctrica por alto voltaje es un factor predictor de mortalidad en pacientes "grandes quemados"
title_full_unstemmed La quemadura eléctrica por alto voltaje es un factor predictor de mortalidad en pacientes "grandes quemados"
title_sort la quemadura eléctrica por alto voltaje es un factor predictor de mortalidad en pacientes "grandes quemados"
publisher Sociedad Médica de Santiago
publishDate 2011
url http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872011000200006
work_keys_str_mv AT mangelsdorffggunther laquemaduraelectricaporaltovoltajeesunfactorpredictordemortalidadenpacientesgrandesquemados
AT garciahuidobrodmangelica laquemaduraelectricaporaltovoltajeesunfactorpredictordemortalidadenpacientesgrandesquemados
AT atenasmomar laquemaduraelectricaporaltovoltajeesunfactorpredictordemortalidadenpacientesgrandesquemados
AT whittlevsandra laquemaduraelectricaporaltovoltajeesunfactorpredictordemortalidadenpacientesgrandesquemados
AT villegascjorge laquemaduraelectricaporaltovoltajeesunfactorpredictordemortalidadenpacientesgrandesquemados
_version_ 1718436551971569664