Prueba de basculación (Tilt Table Testing): Comparación de dos protocolos: isoproterenol versus nitroglicerina
Background: There is debate about the advantages of different protocols usefulness of tilt test for the diagnosis of vasovagal collapse. Aim: To compare the sensitivity, specificity, adverse reactions, complications and time requirements of two different Tilt test protocols. Material and Methods: A...
Guardado en:
Autores principales: | , , , , |
---|---|
Lenguaje: | Spanish / Castilian |
Publicado: |
Sociedad Médica de Santiago
2015
|
Materias: | |
Acceso en línea: | http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872015000100009 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:scielo:S0034-98872015000100009 |
---|---|
record_format |
dspace |
spelling |
oai:scielo:S0034-988720150001000092015-08-11Prueba de basculación (Tilt Table Testing): Comparación de dos protocolos: isoproterenol versus nitroglicerinaJiménez-Cohl,PedroVega,SebastiánCáceres,RocíoGómez,ConstanzaRojas,Nadia Isoproterenol Nitroglycerin Primary dysautonomia Syncope Background: There is debate about the advantages of different protocols usefulness of tilt test for the diagnosis of vasovagal collapse. Aim: To compare the sensitivity, specificity, adverse reactions, complications and time requirements of two different Tilt test protocols. Material and Methods: A Tilt test using isoproterenol in progressive doses (2 μg for 10 min and 5 μg for 5 min posteriorly was performed in 159 patients aged 9 to 84 years (59 males). Another Tilt test using sublingual nitroglycerine in doses of 0.3 mg was performed in 201 patients aged 8 to 87 years (62 males). Also, 20 healthy volunteers were tested. Results: The positivity rates of the tests using isoproterenol and nitroglycerin were 75.5 and 77.6% respectively (NS). The figures for sensitivity were 98.4 and 99.3% (NS). The figures for specificity were 93.2 and 98.4% (NS). The test using isoproterenol requires 15 more minutes. As adverse reactions, 38% of participants experienced palpitations with isoproterenol and 22% experienced headache with nitroglycerin. Conclusions: The Tilt test with nitroglycerin is shorter, simpler, painless, with less personnel involved and has the same diagnostic accuracy than the test with isoproterenol.info:eu-repo/semantics/openAccessSociedad Médica de SantiagoRevista médica de Chile v.143 n.1 20152015-01-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872015000100009es10.4067/S0034-98872015000100009 |
institution |
Scielo Chile |
collection |
Scielo Chile |
language |
Spanish / Castilian |
topic |
Isoproterenol Nitroglycerin Primary dysautonomia Syncope |
spellingShingle |
Isoproterenol Nitroglycerin Primary dysautonomia Syncope Jiménez-Cohl,Pedro Vega,Sebastián Cáceres,Rocío Gómez,Constanza Rojas,Nadia Prueba de basculación (Tilt Table Testing): Comparación de dos protocolos: isoproterenol versus nitroglicerina |
description |
Background: There is debate about the advantages of different protocols usefulness of tilt test for the diagnosis of vasovagal collapse. Aim: To compare the sensitivity, specificity, adverse reactions, complications and time requirements of two different Tilt test protocols. Material and Methods: A Tilt test using isoproterenol in progressive doses (2 μg for 10 min and 5 μg for 5 min posteriorly was performed in 159 patients aged 9 to 84 years (59 males). Another Tilt test using sublingual nitroglycerine in doses of 0.3 mg was performed in 201 patients aged 8 to 87 years (62 males). Also, 20 healthy volunteers were tested. Results: The positivity rates of the tests using isoproterenol and nitroglycerin were 75.5 and 77.6% respectively (NS). The figures for sensitivity were 98.4 and 99.3% (NS). The figures for specificity were 93.2 and 98.4% (NS). The test using isoproterenol requires 15 more minutes. As adverse reactions, 38% of participants experienced palpitations with isoproterenol and 22% experienced headache with nitroglycerin. Conclusions: The Tilt test with nitroglycerin is shorter, simpler, painless, with less personnel involved and has the same diagnostic accuracy than the test with isoproterenol. |
author |
Jiménez-Cohl,Pedro Vega,Sebastián Cáceres,Rocío Gómez,Constanza Rojas,Nadia |
author_facet |
Jiménez-Cohl,Pedro Vega,Sebastián Cáceres,Rocío Gómez,Constanza Rojas,Nadia |
author_sort |
Jiménez-Cohl,Pedro |
title |
Prueba de basculación (Tilt Table Testing): Comparación de dos protocolos: isoproterenol versus nitroglicerina |
title_short |
Prueba de basculación (Tilt Table Testing): Comparación de dos protocolos: isoproterenol versus nitroglicerina |
title_full |
Prueba de basculación (Tilt Table Testing): Comparación de dos protocolos: isoproterenol versus nitroglicerina |
title_fullStr |
Prueba de basculación (Tilt Table Testing): Comparación de dos protocolos: isoproterenol versus nitroglicerina |
title_full_unstemmed |
Prueba de basculación (Tilt Table Testing): Comparación de dos protocolos: isoproterenol versus nitroglicerina |
title_sort |
prueba de basculación (tilt table testing): comparación de dos protocolos: isoproterenol versus nitroglicerina |
publisher |
Sociedad Médica de Santiago |
publishDate |
2015 |
url |
http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872015000100009 |
work_keys_str_mv |
AT jimenezcohlpedro pruebadebasculaciontilttabletestingcomparaciondedosprotocolosisoproterenolversusnitroglicerina AT vegasebastian pruebadebasculaciontilttabletestingcomparaciondedosprotocolosisoproterenolversusnitroglicerina AT caceresrocio pruebadebasculaciontilttabletestingcomparaciondedosprotocolosisoproterenolversusnitroglicerina AT gomezconstanza pruebadebasculaciontilttabletestingcomparaciondedosprotocolosisoproterenolversusnitroglicerina AT rojasnadia pruebadebasculaciontilttabletestingcomparaciondedosprotocolosisoproterenolversusnitroglicerina |
_version_ |
1718436799433408512 |