Prueba de basculación (Tilt Table Testing): Comparación de dos protocolos: isoproterenol versus nitroglicerina

Background: There is debate about the advantages of different protocols usefulness of tilt test for the diagnosis of vasovagal collapse. Aim: To compare the sensitivity, specificity, adverse reactions, complications and time requirements of two different Tilt test protocols. Material and Methods: A...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Jiménez-Cohl,Pedro, Vega,Sebastián, Cáceres,Rocío, Gómez,Constanza, Rojas,Nadia
Lenguaje:Spanish / Castilian
Publicado: Sociedad Médica de Santiago 2015
Materias:
Acceso en línea:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872015000100009
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:scielo:S0034-98872015000100009
record_format dspace
spelling oai:scielo:S0034-988720150001000092015-08-11Prueba de basculación (Tilt Table Testing): Comparación de dos protocolos: isoproterenol versus nitroglicerinaJiménez-Cohl,PedroVega,SebastiánCáceres,RocíoGómez,ConstanzaRojas,Nadia Isoproterenol Nitroglycerin Primary dysautonomia Syncope Background: There is debate about the advantages of different protocols usefulness of tilt test for the diagnosis of vasovagal collapse. Aim: To compare the sensitivity, specificity, adverse reactions, complications and time requirements of two different Tilt test protocols. Material and Methods: A Tilt test using isoproterenol in progressive doses (2 μg for 10 min and 5 μg for 5 min posteriorly was performed in 159 patients aged 9 to 84 years (59 males). Another Tilt test using sublingual nitroglycerine in doses of 0.3 mg was performed in 201 patients aged 8 to 87 years (62 males). Also, 20 healthy volunteers were tested. Results: The positivity rates of the tests using isoproterenol and nitroglycerin were 75.5 and 77.6% respectively (NS). The figures for sensitivity were 98.4 and 99.3% (NS). The figures for specificity were 93.2 and 98.4% (NS). The test using isoproterenol requires 15 more minutes. As adverse reactions, 38% of participants experienced palpitations with isoproterenol and 22% experienced headache with nitroglycerin. Conclusions: The Tilt test with nitroglycerin is shorter, simpler, painless, with less personnel involved and has the same diagnostic accuracy than the test with isoproterenol.info:eu-repo/semantics/openAccessSociedad Médica de SantiagoRevista médica de Chile v.143 n.1 20152015-01-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872015000100009es10.4067/S0034-98872015000100009
institution Scielo Chile
collection Scielo Chile
language Spanish / Castilian
topic Isoproterenol
Nitroglycerin
Primary dysautonomia
Syncope
spellingShingle Isoproterenol
Nitroglycerin
Primary dysautonomia
Syncope
Jiménez-Cohl,Pedro
Vega,Sebastián
Cáceres,Rocío
Gómez,Constanza
Rojas,Nadia
Prueba de basculación (Tilt Table Testing): Comparación de dos protocolos: isoproterenol versus nitroglicerina
description Background: There is debate about the advantages of different protocols usefulness of tilt test for the diagnosis of vasovagal collapse. Aim: To compare the sensitivity, specificity, adverse reactions, complications and time requirements of two different Tilt test protocols. Material and Methods: A Tilt test using isoproterenol in progressive doses (2 μg for 10 min and 5 μg for 5 min posteriorly was performed in 159 patients aged 9 to 84 years (59 males). Another Tilt test using sublingual nitroglycerine in doses of 0.3 mg was performed in 201 patients aged 8 to 87 years (62 males). Also, 20 healthy volunteers were tested. Results: The positivity rates of the tests using isoproterenol and nitroglycerin were 75.5 and 77.6% respectively (NS). The figures for sensitivity were 98.4 and 99.3% (NS). The figures for specificity were 93.2 and 98.4% (NS). The test using isoproterenol requires 15 more minutes. As adverse reactions, 38% of participants experienced palpitations with isoproterenol and 22% experienced headache with nitroglycerin. Conclusions: The Tilt test with nitroglycerin is shorter, simpler, painless, with less personnel involved and has the same diagnostic accuracy than the test with isoproterenol.
author Jiménez-Cohl,Pedro
Vega,Sebastián
Cáceres,Rocío
Gómez,Constanza
Rojas,Nadia
author_facet Jiménez-Cohl,Pedro
Vega,Sebastián
Cáceres,Rocío
Gómez,Constanza
Rojas,Nadia
author_sort Jiménez-Cohl,Pedro
title Prueba de basculación (Tilt Table Testing): Comparación de dos protocolos: isoproterenol versus nitroglicerina
title_short Prueba de basculación (Tilt Table Testing): Comparación de dos protocolos: isoproterenol versus nitroglicerina
title_full Prueba de basculación (Tilt Table Testing): Comparación de dos protocolos: isoproterenol versus nitroglicerina
title_fullStr Prueba de basculación (Tilt Table Testing): Comparación de dos protocolos: isoproterenol versus nitroglicerina
title_full_unstemmed Prueba de basculación (Tilt Table Testing): Comparación de dos protocolos: isoproterenol versus nitroglicerina
title_sort prueba de basculación (tilt table testing): comparación de dos protocolos: isoproterenol versus nitroglicerina
publisher Sociedad Médica de Santiago
publishDate 2015
url http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872015000100009
work_keys_str_mv AT jimenezcohlpedro pruebadebasculaciontilttabletestingcomparaciondedosprotocolosisoproterenolversusnitroglicerina
AT vegasebastian pruebadebasculaciontilttabletestingcomparaciondedosprotocolosisoproterenolversusnitroglicerina
AT caceresrocio pruebadebasculaciontilttabletestingcomparaciondedosprotocolosisoproterenolversusnitroglicerina
AT gomezconstanza pruebadebasculaciontilttabletestingcomparaciondedosprotocolosisoproterenolversusnitroglicerina
AT rojasnadia pruebadebasculaciontilttabletestingcomparaciondedosprotocolosisoproterenolversusnitroglicerina
_version_ 1718436799433408512