¿Es eficiente la protección anti-radiación otorgada por gorros de pabellón de tungsteno-bismuto en cardiología intervencionista?
Background: The effectiveness against radiation of tungsten bismuth caps, used in interventional cardiology is not well known. Aim: To determine the degree of radiation protection conferred by these caps in real work conditions. Material and Methods: We compared the gross electric charges received a...
Guardado en:
Autores principales: | , , , , |
---|---|
Lenguaje: | Spanish / Castilian |
Publicado: |
Sociedad Médica de Santiago
2016
|
Materias: | |
Acceso en línea: | http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872016000700003 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:scielo:S0034-98872016000700003 |
---|---|
record_format |
dspace |
spelling |
oai:scielo:S0034-988720160007000032016-10-03¿Es eficiente la protección anti-radiación otorgada por gorros de pabellón de tungsteno-bismuto en cardiología intervencionista?Ramos-Avasola,SergioDíaz,NataliaRoldán,ReynaldoGamarra,JorgeCatalán,Mónica Endovascular Procedures Occupational Exposure Occupational Health Radiation Protection Background: The effectiveness against radiation of tungsten bismuth caps, used in interventional cardiology is not well known. Aim: To determine the degree of radiation protection conferred by these caps in real work conditions. Material and Methods: We compared the gross electric charges received at brain lobe levels by three occupationally exposed professionals who participated in 22 consecutive procedures, inside and outside of the tungsten bismuth cap. Results: The median electric charges outside and inside the cap were 3.71 (range 1.46-5.62) and 2.2 (range 1.29-3.93) nC, which correspond to a 40% radiation attenuation. However, the protection was heterogeneous. Conclusions: Tungsten bismuth caps provide an adequate attenuation, but its degree is heterogeneous.info:eu-repo/semantics/openAccessSociedad Médica de SantiagoRevista médica de Chile v.144 n.7 20162016-07-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872016000700003es10.4067/S0034-98872016000700003 |
institution |
Scielo Chile |
collection |
Scielo Chile |
language |
Spanish / Castilian |
topic |
Endovascular Procedures Occupational Exposure Occupational Health Radiation Protection |
spellingShingle |
Endovascular Procedures Occupational Exposure Occupational Health Radiation Protection Ramos-Avasola,Sergio Díaz,Natalia Roldán,Reynaldo Gamarra,Jorge Catalán,Mónica ¿Es eficiente la protección anti-radiación otorgada por gorros de pabellón de tungsteno-bismuto en cardiología intervencionista? |
description |
Background: The effectiveness against radiation of tungsten bismuth caps, used in interventional cardiology is not well known. Aim: To determine the degree of radiation protection conferred by these caps in real work conditions. Material and Methods: We compared the gross electric charges received at brain lobe levels by three occupationally exposed professionals who participated in 22 consecutive procedures, inside and outside of the tungsten bismuth cap. Results: The median electric charges outside and inside the cap were 3.71 (range 1.46-5.62) and 2.2 (range 1.29-3.93) nC, which correspond to a 40% radiation attenuation. However, the protection was heterogeneous. Conclusions: Tungsten bismuth caps provide an adequate attenuation, but its degree is heterogeneous. |
author |
Ramos-Avasola,Sergio Díaz,Natalia Roldán,Reynaldo Gamarra,Jorge Catalán,Mónica |
author_facet |
Ramos-Avasola,Sergio Díaz,Natalia Roldán,Reynaldo Gamarra,Jorge Catalán,Mónica |
author_sort |
Ramos-Avasola,Sergio |
title |
¿Es eficiente la protección anti-radiación otorgada por gorros de pabellón de tungsteno-bismuto en cardiología intervencionista? |
title_short |
¿Es eficiente la protección anti-radiación otorgada por gorros de pabellón de tungsteno-bismuto en cardiología intervencionista? |
title_full |
¿Es eficiente la protección anti-radiación otorgada por gorros de pabellón de tungsteno-bismuto en cardiología intervencionista? |
title_fullStr |
¿Es eficiente la protección anti-radiación otorgada por gorros de pabellón de tungsteno-bismuto en cardiología intervencionista? |
title_full_unstemmed |
¿Es eficiente la protección anti-radiación otorgada por gorros de pabellón de tungsteno-bismuto en cardiología intervencionista? |
title_sort |
¿es eficiente la protección anti-radiación otorgada por gorros de pabellón de tungsteno-bismuto en cardiología intervencionista? |
publisher |
Sociedad Médica de Santiago |
publishDate |
2016 |
url |
http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872016000700003 |
work_keys_str_mv |
AT ramosavasolasergio eseficientelaproteccionantiradiacionotorgadaporgorrosdepabellondetungstenobismutoencardiologiaintervencionista AT diaznatalia eseficientelaproteccionantiradiacionotorgadaporgorrosdepabellondetungstenobismutoencardiologiaintervencionista AT roldanreynaldo eseficientelaproteccionantiradiacionotorgadaporgorrosdepabellondetungstenobismutoencardiologiaintervencionista AT gamarrajorge eseficientelaproteccionantiradiacionotorgadaporgorrosdepabellondetungstenobismutoencardiologiaintervencionista AT catalanmonica eseficientelaproteccionantiradiacionotorgadaporgorrosdepabellondetungstenobismutoencardiologiaintervencionista |
_version_ |
1718436892787081216 |