Eficacia y tolerabilidad de la reducción del volumen de polietilenglicol para la preparación para colonoscopia

Background: A successful colonoscopy depends, among other factors, on a proper colon cleansing. This variable also affects the acceptance of the patient to carry out the study. Aim: To analyze the efficacy and tolerability of a low volume polyethylene glycol formulation (2 liters), compared to the...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: López,Soledad, Vargas,Claudio, López,Carolina
Lenguaje:Spanish / Castilian
Publicado: Sociedad Médica de Santiago 2019
Materias:
Acceso en línea:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872019000800977
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:scielo:S0034-98872019000800977
record_format dspace
spelling oai:scielo:S0034-988720190008009772019-10-24Eficacia y tolerabilidad de la reducción del volumen de polietilenglicol para la preparación para colonoscopiaLópez,SoledadVargas,ClaudioLópez,Carolina Cathartics Colonoscopy Chile Polyethylene Glycols Background: A successful colonoscopy depends, among other factors, on a proper colon cleansing. This variable also affects the acceptance of the patient to carry out the study. Aim: To analyze the efficacy and tolerability of a low volume polyethylene glycol formulation (2 liters), compared to the conventional presentation of 4 liters. Material and Methods: Patients referred for a colonoscopy were randomly divided to receive either two or four liter of polyethylene glycol as bowel cleansing, which was assessed using the Boston score. Raters of the latter were blinded to the volume of polyethylene glycol that the patients used. Results: Seventy-four patients participated in the study. Subjects who received a 4 liters preparation had an average Boston score of 7.78, versus 8.16 for patients who received a volume of 2 liters (p = 0.267). No significant differences in tolerability were observed between both groups. No significant differences in the efficacy and tolerability between a conventional or a reduced volume of polyethylene glycol solution for the preparation of a colonoscopy were observed. These findings may be especially important for subgroups of patients with difficulties for oral administration of fluids.info:eu-repo/semantics/openAccessSociedad Médica de SantiagoRevista médica de Chile v.147 n.8 20192019-08-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872019000800977es10.4067/S0034-98872019000800977
institution Scielo Chile
collection Scielo Chile
language Spanish / Castilian
topic Cathartics
Colonoscopy
Chile
Polyethylene Glycols
spellingShingle Cathartics
Colonoscopy
Chile
Polyethylene Glycols
López,Soledad
Vargas,Claudio
López,Carolina
Eficacia y tolerabilidad de la reducción del volumen de polietilenglicol para la preparación para colonoscopia
description Background: A successful colonoscopy depends, among other factors, on a proper colon cleansing. This variable also affects the acceptance of the patient to carry out the study. Aim: To analyze the efficacy and tolerability of a low volume polyethylene glycol formulation (2 liters), compared to the conventional presentation of 4 liters. Material and Methods: Patients referred for a colonoscopy were randomly divided to receive either two or four liter of polyethylene glycol as bowel cleansing, which was assessed using the Boston score. Raters of the latter were blinded to the volume of polyethylene glycol that the patients used. Results: Seventy-four patients participated in the study. Subjects who received a 4 liters preparation had an average Boston score of 7.78, versus 8.16 for patients who received a volume of 2 liters (p = 0.267). No significant differences in tolerability were observed between both groups. No significant differences in the efficacy and tolerability between a conventional or a reduced volume of polyethylene glycol solution for the preparation of a colonoscopy were observed. These findings may be especially important for subgroups of patients with difficulties for oral administration of fluids.
author López,Soledad
Vargas,Claudio
López,Carolina
author_facet López,Soledad
Vargas,Claudio
López,Carolina
author_sort López,Soledad
title Eficacia y tolerabilidad de la reducción del volumen de polietilenglicol para la preparación para colonoscopia
title_short Eficacia y tolerabilidad de la reducción del volumen de polietilenglicol para la preparación para colonoscopia
title_full Eficacia y tolerabilidad de la reducción del volumen de polietilenglicol para la preparación para colonoscopia
title_fullStr Eficacia y tolerabilidad de la reducción del volumen de polietilenglicol para la preparación para colonoscopia
title_full_unstemmed Eficacia y tolerabilidad de la reducción del volumen de polietilenglicol para la preparación para colonoscopia
title_sort eficacia y tolerabilidad de la reducción del volumen de polietilenglicol para la preparación para colonoscopia
publisher Sociedad Médica de Santiago
publishDate 2019
url http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872019000800977
work_keys_str_mv AT lopezsoledad eficaciaytolerabilidaddelareducciondelvolumendepolietilenglicolparalapreparacionparacolonoscopia
AT vargasclaudio eficaciaytolerabilidaddelareducciondelvolumendepolietilenglicolparalapreparacionparacolonoscopia
AT lopezcarolina eficaciaytolerabilidaddelareducciondelvolumendepolietilenglicolparalapreparacionparacolonoscopia
_version_ 1718437076932755456