Concordance between estimated glomerular filtration rate using equations and that measured using an imaging method

ABSTRACT Background: Guidelines recommend estimating glomerular filtration rate (GFR) using creatinine-based equations (CBE). Aim: To evaluate the agreement between GFR measured using radionuclide imaging and estimated using creatinine-based equations. Material and Methods: In 421 patients aged 5...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: González G.,Camilo A., Durán Camero,Alejandro, Vargas,María Teresa, García,Paola K., Contreras,Kateir, Rodríguez,Patricia
Lenguaje:English
Publicado: Sociedad Médica de Santiago 2021
Materias:
Acceso en línea:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872021000100013
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:scielo:S0034-98872021000100013
record_format dspace
spelling oai:scielo:S0034-988720210001000132021-05-09Concordance between estimated glomerular filtration rate using equations and that measured using an imaging methodGonzález G.,Camilo A.Durán Camero,AlejandroVargas,María TeresaGarcía,Paola K.Contreras,KateirRodríguez,Patricia Glomerular Filtration Rate Kidney Function Tests Radionuclide Imaging Renal Insufficiency, Chronic ABSTRACT Background: Guidelines recommend estimating glomerular filtration rate (GFR) using creatinine-based equations (CBE). Aim: To evaluate the agreement between GFR measured using radionuclide imaging and estimated using creatinine-based equations. Material and Methods: In 421 patients aged 54 ± 17 years (47% women) GFR was estimated using the MDRD-4, CKD-EPI and the body surface adjusted Cockroft Gault equation. GFR was also measured using a radionuclide imaging method with 99mTc-DTPA. The concordance between estimated and measured GFR was calculated using Lin's concordance coefficient and Bland and Altman plots. Results: Average GFR values obtained with CKD-EPI, MDRD-4, body surface adjusted Cockroft Gault equation and 99mTc-DTPA imaging were 75.9 ± 26.6, 76.3 ± 28.8, 77.1 ± 31.6 and 77.9 ± 28.4 ml/min/1.73 m2, respectively. There was no significant difference in means and 29% of participants had a GFR < 60 ml/min/1.73 m2 by CKD-EPI. The correlation was good between equations, but acceptable when compared with the 99mTc-DTPA imaging. The weighted kappa between CBEs was good, but low when comparing CBEs with measured GFR. The Lin's concordance coefficient between estimated and measured GFR was low. Conclusions: GFR measured by 99mTc-DTPA radionuclide imaging has a low correlation and poor concordance with estimations using CBE.info:eu-repo/semantics/openAccessSociedad Médica de SantiagoRevista médica de Chile v.149 n.1 20212021-01-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872021000100013en10.4067/S0034-98872021000100013
institution Scielo Chile
collection Scielo Chile
language English
topic Glomerular Filtration Rate
Kidney Function Tests
Radionuclide Imaging
Renal Insufficiency, Chronic
spellingShingle Glomerular Filtration Rate
Kidney Function Tests
Radionuclide Imaging
Renal Insufficiency, Chronic
González G.,Camilo A.
Durán Camero,Alejandro
Vargas,María Teresa
García,Paola K.
Contreras,Kateir
Rodríguez,Patricia
Concordance between estimated glomerular filtration rate using equations and that measured using an imaging method
description ABSTRACT Background: Guidelines recommend estimating glomerular filtration rate (GFR) using creatinine-based equations (CBE). Aim: To evaluate the agreement between GFR measured using radionuclide imaging and estimated using creatinine-based equations. Material and Methods: In 421 patients aged 54 ± 17 years (47% women) GFR was estimated using the MDRD-4, CKD-EPI and the body surface adjusted Cockroft Gault equation. GFR was also measured using a radionuclide imaging method with 99mTc-DTPA. The concordance between estimated and measured GFR was calculated using Lin's concordance coefficient and Bland and Altman plots. Results: Average GFR values obtained with CKD-EPI, MDRD-4, body surface adjusted Cockroft Gault equation and 99mTc-DTPA imaging were 75.9 ± 26.6, 76.3 ± 28.8, 77.1 ± 31.6 and 77.9 ± 28.4 ml/min/1.73 m2, respectively. There was no significant difference in means and 29% of participants had a GFR < 60 ml/min/1.73 m2 by CKD-EPI. The correlation was good between equations, but acceptable when compared with the 99mTc-DTPA imaging. The weighted kappa between CBEs was good, but low when comparing CBEs with measured GFR. The Lin's concordance coefficient between estimated and measured GFR was low. Conclusions: GFR measured by 99mTc-DTPA radionuclide imaging has a low correlation and poor concordance with estimations using CBE.
author González G.,Camilo A.
Durán Camero,Alejandro
Vargas,María Teresa
García,Paola K.
Contreras,Kateir
Rodríguez,Patricia
author_facet González G.,Camilo A.
Durán Camero,Alejandro
Vargas,María Teresa
García,Paola K.
Contreras,Kateir
Rodríguez,Patricia
author_sort González G.,Camilo A.
title Concordance between estimated glomerular filtration rate using equations and that measured using an imaging method
title_short Concordance between estimated glomerular filtration rate using equations and that measured using an imaging method
title_full Concordance between estimated glomerular filtration rate using equations and that measured using an imaging method
title_fullStr Concordance between estimated glomerular filtration rate using equations and that measured using an imaging method
title_full_unstemmed Concordance between estimated glomerular filtration rate using equations and that measured using an imaging method
title_sort concordance between estimated glomerular filtration rate using equations and that measured using an imaging method
publisher Sociedad Médica de Santiago
publishDate 2021
url http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872021000100013
work_keys_str_mv AT gonzalezgcamiloa concordancebetweenestimatedglomerularfiltrationrateusingequationsandthatmeasuredusinganimagingmethod
AT durancameroalejandro concordancebetweenestimatedglomerularfiltrationrateusingequationsandthatmeasuredusinganimagingmethod
AT vargasmariateresa concordancebetweenestimatedglomerularfiltrationrateusingequationsandthatmeasuredusinganimagingmethod
AT garciapaolak concordancebetweenestimatedglomerularfiltrationrateusingequationsandthatmeasuredusinganimagingmethod
AT contreraskateir concordancebetweenestimatedglomerularfiltrationrateusingequationsandthatmeasuredusinganimagingmethod
AT rodriguezpatricia concordancebetweenestimatedglomerularfiltrationrateusingequationsandthatmeasuredusinganimagingmethod
_version_ 1718437176436326400