Concordance between estimated glomerular filtration rate using equations and that measured using an imaging method
ABSTRACT Background: Guidelines recommend estimating glomerular filtration rate (GFR) using creatinine-based equations (CBE). Aim: To evaluate the agreement between GFR measured using radionuclide imaging and estimated using creatinine-based equations. Material and Methods: In 421 patients aged 5...
Guardado en:
Autores principales: | , , , , , |
---|---|
Lenguaje: | English |
Publicado: |
Sociedad Médica de Santiago
2021
|
Materias: | |
Acceso en línea: | http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872021000100013 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:scielo:S0034-98872021000100013 |
---|---|
record_format |
dspace |
spelling |
oai:scielo:S0034-988720210001000132021-05-09Concordance between estimated glomerular filtration rate using equations and that measured using an imaging methodGonzález G.,Camilo A.Durán Camero,AlejandroVargas,María TeresaGarcía,Paola K.Contreras,KateirRodríguez,Patricia Glomerular Filtration Rate Kidney Function Tests Radionuclide Imaging Renal Insufficiency, Chronic ABSTRACT Background: Guidelines recommend estimating glomerular filtration rate (GFR) using creatinine-based equations (CBE). Aim: To evaluate the agreement between GFR measured using radionuclide imaging and estimated using creatinine-based equations. Material and Methods: In 421 patients aged 54 ± 17 years (47% women) GFR was estimated using the MDRD-4, CKD-EPI and the body surface adjusted Cockroft Gault equation. GFR was also measured using a radionuclide imaging method with 99mTc-DTPA. The concordance between estimated and measured GFR was calculated using Lin's concordance coefficient and Bland and Altman plots. Results: Average GFR values obtained with CKD-EPI, MDRD-4, body surface adjusted Cockroft Gault equation and 99mTc-DTPA imaging were 75.9 ± 26.6, 76.3 ± 28.8, 77.1 ± 31.6 and 77.9 ± 28.4 ml/min/1.73 m2, respectively. There was no significant difference in means and 29% of participants had a GFR < 60 ml/min/1.73 m2 by CKD-EPI. The correlation was good between equations, but acceptable when compared with the 99mTc-DTPA imaging. The weighted kappa between CBEs was good, but low when comparing CBEs with measured GFR. The Lin's concordance coefficient between estimated and measured GFR was low. Conclusions: GFR measured by 99mTc-DTPA radionuclide imaging has a low correlation and poor concordance with estimations using CBE.info:eu-repo/semantics/openAccessSociedad Médica de SantiagoRevista médica de Chile v.149 n.1 20212021-01-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872021000100013en10.4067/S0034-98872021000100013 |
institution |
Scielo Chile |
collection |
Scielo Chile |
language |
English |
topic |
Glomerular Filtration Rate Kidney Function Tests Radionuclide Imaging Renal Insufficiency, Chronic |
spellingShingle |
Glomerular Filtration Rate Kidney Function Tests Radionuclide Imaging Renal Insufficiency, Chronic González G.,Camilo A. Durán Camero,Alejandro Vargas,María Teresa García,Paola K. Contreras,Kateir Rodríguez,Patricia Concordance between estimated glomerular filtration rate using equations and that measured using an imaging method |
description |
ABSTRACT Background: Guidelines recommend estimating glomerular filtration rate (GFR) using creatinine-based equations (CBE). Aim: To evaluate the agreement between GFR measured using radionuclide imaging and estimated using creatinine-based equations. Material and Methods: In 421 patients aged 54 ± 17 years (47% women) GFR was estimated using the MDRD-4, CKD-EPI and the body surface adjusted Cockroft Gault equation. GFR was also measured using a radionuclide imaging method with 99mTc-DTPA. The concordance between estimated and measured GFR was calculated using Lin's concordance coefficient and Bland and Altman plots. Results: Average GFR values obtained with CKD-EPI, MDRD-4, body surface adjusted Cockroft Gault equation and 99mTc-DTPA imaging were 75.9 ± 26.6, 76.3 ± 28.8, 77.1 ± 31.6 and 77.9 ± 28.4 ml/min/1.73 m2, respectively. There was no significant difference in means and 29% of participants had a GFR < 60 ml/min/1.73 m2 by CKD-EPI. The correlation was good between equations, but acceptable when compared with the 99mTc-DTPA imaging. The weighted kappa between CBEs was good, but low when comparing CBEs with measured GFR. The Lin's concordance coefficient between estimated and measured GFR was low. Conclusions: GFR measured by 99mTc-DTPA radionuclide imaging has a low correlation and poor concordance with estimations using CBE. |
author |
González G.,Camilo A. Durán Camero,Alejandro Vargas,María Teresa García,Paola K. Contreras,Kateir Rodríguez,Patricia |
author_facet |
González G.,Camilo A. Durán Camero,Alejandro Vargas,María Teresa García,Paola K. Contreras,Kateir Rodríguez,Patricia |
author_sort |
González G.,Camilo A. |
title |
Concordance between estimated glomerular filtration rate using equations and that measured using an imaging method |
title_short |
Concordance between estimated glomerular filtration rate using equations and that measured using an imaging method |
title_full |
Concordance between estimated glomerular filtration rate using equations and that measured using an imaging method |
title_fullStr |
Concordance between estimated glomerular filtration rate using equations and that measured using an imaging method |
title_full_unstemmed |
Concordance between estimated glomerular filtration rate using equations and that measured using an imaging method |
title_sort |
concordance between estimated glomerular filtration rate using equations and that measured using an imaging method |
publisher |
Sociedad Médica de Santiago |
publishDate |
2021 |
url |
http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0034-98872021000100013 |
work_keys_str_mv |
AT gonzalezgcamiloa concordancebetweenestimatedglomerularfiltrationrateusingequationsandthatmeasuredusinganimagingmethod AT durancameroalejandro concordancebetweenestimatedglomerularfiltrationrateusingequationsandthatmeasuredusinganimagingmethod AT vargasmariateresa concordancebetweenestimatedglomerularfiltrationrateusingequationsandthatmeasuredusinganimagingmethod AT garciapaolak concordancebetweenestimatedglomerularfiltrationrateusingequationsandthatmeasuredusinganimagingmethod AT contreraskateir concordancebetweenestimatedglomerularfiltrationrateusingequationsandthatmeasuredusinganimagingmethod AT rodriguezpatricia concordancebetweenestimatedglomerularfiltrationrateusingequationsandthatmeasuredusinganimagingmethod |
_version_ |
1718437176436326400 |