Application of the EROD-H4IIE bioassay for the determination of dioxins in pork in comparison to high resolution gas chromatography coupled to high resolution mass spectrometry

The EROD-H4IIE cell bioassay is a screening method for the detection of planar halogenated hydrocarbons (PHH), it has several advantages over analytical chemistry like speed, simplicity, accuracy, high sensitivity and low cost which makes it a valuable bioassay for biomonitoring studies. It has been...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Valdovinos,CE, Sotomayor,P, Stech,R, Schoffer,JT, Bustos-López,C
Lenguaje:English
Publicado: Facultad de Ciencias Veterinarias, Universidad Austral de Chile 2013
Materias:
Acceso en línea:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0301-732X2013000200009
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:scielo:S0301-732X2013000200009
record_format dspace
spelling oai:scielo:S0301-732X20130002000092013-09-03Application of the EROD-H4IIE bioassay for the determination of dioxins in pork in comparison to high resolution gas chromatography coupled to high resolution mass spectrometryValdovinos,CESotomayor,PStech,RSchoffer,JTBustos-López,C dioxins EROD/H4IIE HRGC/HRMS pork The EROD-H4IIE cell bioassay is a screening method for the detection of planar halogenated hydrocarbons (PHH), it has several advantages over analytical chemistry like speed, simplicity, accuracy, high sensitivity and low cost which makes it a valuable bioassay for biomonitoring studies. It has been successfully used as screening method for the detection of dioxins and furans (PCDD/Fs) in meat from broiler chicken. The aim of this study was to detect PCDD/Fs in pork, by using both the bioassay and the high resolution gas chromatography/high resolution mass spectrometry (HRGC/ HRMS). 59 composite samples of pork chuck loin were taken at a slaughtering plant of 6 Chilean production facilities between 2004 and 2007, with one sample being taken in 2011. Mean concentrations of PCDD/Fs obtained by HRGC/HRMS ranged between 0.22 and 0.34 pg WHO-TEQ/g fat. The maximum was 0.71 pg WHO-TEQ/g fat. The average value of the congeners was 0.1 pg WHO-TEQ fat-2,3,4,7,8-PeCDF (between 0.03 and 0.28 pg/g fat). Therefore, the samples did not exceed the maximum allowed by national and international legislation. When comparing the results obtained with the two methods, 36 out of 59 sample results were overestimated by the bioassay, while 19 were underestimated and 4 were similar. 15 samples exceeded 1 pg/g TCDD-EQ tissue and only 5 exceeded 2 pg TCDD-EQ/g tissue. It was not possible to establish an equivalence between EROD-H4IIE and HRGC/ HRMS for the detection of PCDD/Fs in pork since there was not a significant association between variables (r = -0.142, P ≥ 0.2840).info:eu-repo/semantics/openAccessFacultad de Ciencias Veterinarias, Universidad Austral de ChileArchivos de medicina veterinaria v.45 n.2 20132013-01-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0301-732X2013000200009en10.4067/S0301-732X2013000200009
institution Scielo Chile
collection Scielo Chile
language English
topic dioxins
EROD/H4IIE
HRGC/HRMS
pork
spellingShingle dioxins
EROD/H4IIE
HRGC/HRMS
pork
Valdovinos,CE
Sotomayor,P
Stech,R
Schoffer,JT
Bustos-López,C
Application of the EROD-H4IIE bioassay for the determination of dioxins in pork in comparison to high resolution gas chromatography coupled to high resolution mass spectrometry
description The EROD-H4IIE cell bioassay is a screening method for the detection of planar halogenated hydrocarbons (PHH), it has several advantages over analytical chemistry like speed, simplicity, accuracy, high sensitivity and low cost which makes it a valuable bioassay for biomonitoring studies. It has been successfully used as screening method for the detection of dioxins and furans (PCDD/Fs) in meat from broiler chicken. The aim of this study was to detect PCDD/Fs in pork, by using both the bioassay and the high resolution gas chromatography/high resolution mass spectrometry (HRGC/ HRMS). 59 composite samples of pork chuck loin were taken at a slaughtering plant of 6 Chilean production facilities between 2004 and 2007, with one sample being taken in 2011. Mean concentrations of PCDD/Fs obtained by HRGC/HRMS ranged between 0.22 and 0.34 pg WHO-TEQ/g fat. The maximum was 0.71 pg WHO-TEQ/g fat. The average value of the congeners was 0.1 pg WHO-TEQ fat-2,3,4,7,8-PeCDF (between 0.03 and 0.28 pg/g fat). Therefore, the samples did not exceed the maximum allowed by national and international legislation. When comparing the results obtained with the two methods, 36 out of 59 sample results were overestimated by the bioassay, while 19 were underestimated and 4 were similar. 15 samples exceeded 1 pg/g TCDD-EQ tissue and only 5 exceeded 2 pg TCDD-EQ/g tissue. It was not possible to establish an equivalence between EROD-H4IIE and HRGC/ HRMS for the detection of PCDD/Fs in pork since there was not a significant association between variables (r = -0.142, P ≥ 0.2840).
author Valdovinos,CE
Sotomayor,P
Stech,R
Schoffer,JT
Bustos-López,C
author_facet Valdovinos,CE
Sotomayor,P
Stech,R
Schoffer,JT
Bustos-López,C
author_sort Valdovinos,CE
title Application of the EROD-H4IIE bioassay for the determination of dioxins in pork in comparison to high resolution gas chromatography coupled to high resolution mass spectrometry
title_short Application of the EROD-H4IIE bioassay for the determination of dioxins in pork in comparison to high resolution gas chromatography coupled to high resolution mass spectrometry
title_full Application of the EROD-H4IIE bioassay for the determination of dioxins in pork in comparison to high resolution gas chromatography coupled to high resolution mass spectrometry
title_fullStr Application of the EROD-H4IIE bioassay for the determination of dioxins in pork in comparison to high resolution gas chromatography coupled to high resolution mass spectrometry
title_full_unstemmed Application of the EROD-H4IIE bioassay for the determination of dioxins in pork in comparison to high resolution gas chromatography coupled to high resolution mass spectrometry
title_sort application of the erod-h4iie bioassay for the determination of dioxins in pork in comparison to high resolution gas chromatography coupled to high resolution mass spectrometry
publisher Facultad de Ciencias Veterinarias, Universidad Austral de Chile
publishDate 2013
url http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0301-732X2013000200009
work_keys_str_mv AT valdovinosce applicationoftheerodh4iiebioassayforthedeterminationofdioxinsinporkincomparisontohighresolutiongaschromatographycoupledtohighresolutionmassspectrometry
AT sotomayorp applicationoftheerodh4iiebioassayforthedeterminationofdioxinsinporkincomparisontohighresolutiongaschromatographycoupledtohighresolutionmassspectrometry
AT stechr applicationoftheerodh4iiebioassayforthedeterminationofdioxinsinporkincomparisontohighresolutiongaschromatographycoupledtohighresolutionmassspectrometry
AT schofferjt applicationoftheerodh4iiebioassayforthedeterminationofdioxinsinporkincomparisontohighresolutiongaschromatographycoupledtohighresolutionmassspectrometry
AT bustoslopezc applicationoftheerodh4iiebioassayforthedeterminationofdioxinsinporkincomparisontohighresolutiongaschromatographycoupledtohighresolutionmassspectrometry
_version_ 1718437920289849344