DETERMINATION OF Cd IN MUSSELS AND NON-FAT MILK POWDER BY FLOW INJECTION - FLAME ATOMIC ABSORPTION SPECTROPHOTOMETRY (FI-FAAS) WITH ON-LINE EXTRACTION BY A CHELATING RESIN

A simple low-cost FI-FAAS methodology was developed for determination of Cd traces in food samples using preconcentration by on-line extraction in a chelating resin, a strategy usually applied for analytical measurements in water samples. In the case of food samples, a more complex matrix medium, th...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Bruhn,Carlos G., Campos,Víctor H., Díaz,Víctor P., Cid,Hernán J., Nóbrega,Joaquim A.
Lenguaje:English
Publicado: Sociedad Chilena de Química 2002
Materias:
Acceso en línea:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0366-16442002000200008
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:scielo:S0366-16442002000200008
record_format dspace
spelling oai:scielo:S0366-164420020002000082002-10-14DETERMINATION OF Cd IN MUSSELS AND NON-FAT MILK POWDER BY FLOW INJECTION - FLAME ATOMIC ABSORPTION SPECTROPHOTOMETRY (FI-FAAS) WITH ON-LINE EXTRACTION BY A CHELATING RESINBruhn,Carlos G.Campos,Víctor H.Díaz,Víctor P.Cid,Hernán J.Nóbrega,Joaquim A. Flow injection flame atomic absorption spectrophotometry cadmium chelating resin food samples A simple low-cost FI-FAAS methodology was developed for determination of Cd traces in food samples using preconcentration by on-line extraction in a chelating resin, a strategy usually applied for analytical measurements in water samples. In the case of food samples, a more complex matrix medium, the pH of acid digested solutions (pH 1) was raised first to pH 3-5 off-line with 0.5 mol/L NH3, and then was on-line adjusted to pH 8.0 with ammonium acetate buffer (1.15 mol/L CH3COOH / 2.0 mol/L NH3) to proper retention of Cd as Cd-8-hydroxiquinoline complex, minimizing interferences. Cadmium was preconcentrated in a minicolumn filled with 8-hydroxiquinoline azo-immobilized on controlled-pore glass (80 mg). A multivariate approach was adopted to establish the main parameters involved in the FI system. Subsequently, the sample, eluent, and buffer flow rates were optimized using an univariate approach. An enrichment factor of 27 was achieved for 3.0 mL of reference solution and the sampling frequency was 63 h-1. The detection limit (3sBL / slope) was 0.7 and 0.4 mg/L for a preconcentration time of 30 and 60 s, respectively. The developed methodology was validated employing certified reference materials (Oyster tissue, Mussel, and Spiked skim milk powder) and the determined and certified values are in agreement (95% confidence level). The methodology was applied for trace levels determination of Cd in lyophilized mussel samples from the Chilean coast and non-fat milk powder, and a comparison made with graphite furnace electrothermal atomization (ETAAS) showed no statistically significant differences in results (95% confidence level)info:eu-repo/semantics/openAccessSociedad Chilena de QuímicaBoletín de la Sociedad Chilena de Química v.47 n.2 20022002-06-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0366-16442002000200008en10.4067/S0366-16442002000200008
institution Scielo Chile
collection Scielo Chile
language English
topic Flow injection
flame atomic absorption spectrophotometry
cadmium
chelating resin
food samples
spellingShingle Flow injection
flame atomic absorption spectrophotometry
cadmium
chelating resin
food samples
Bruhn,Carlos G.
Campos,Víctor H.
Díaz,Víctor P.
Cid,Hernán J.
Nóbrega,Joaquim A.
DETERMINATION OF Cd IN MUSSELS AND NON-FAT MILK POWDER BY FLOW INJECTION - FLAME ATOMIC ABSORPTION SPECTROPHOTOMETRY (FI-FAAS) WITH ON-LINE EXTRACTION BY A CHELATING RESIN
description A simple low-cost FI-FAAS methodology was developed for determination of Cd traces in food samples using preconcentration by on-line extraction in a chelating resin, a strategy usually applied for analytical measurements in water samples. In the case of food samples, a more complex matrix medium, the pH of acid digested solutions (pH 1) was raised first to pH 3-5 off-line with 0.5 mol/L NH3, and then was on-line adjusted to pH 8.0 with ammonium acetate buffer (1.15 mol/L CH3COOH / 2.0 mol/L NH3) to proper retention of Cd as Cd-8-hydroxiquinoline complex, minimizing interferences. Cadmium was preconcentrated in a minicolumn filled with 8-hydroxiquinoline azo-immobilized on controlled-pore glass (80 mg). A multivariate approach was adopted to establish the main parameters involved in the FI system. Subsequently, the sample, eluent, and buffer flow rates were optimized using an univariate approach. An enrichment factor of 27 was achieved for 3.0 mL of reference solution and the sampling frequency was 63 h-1. The detection limit (3sBL / slope) was 0.7 and 0.4 mg/L for a preconcentration time of 30 and 60 s, respectively. The developed methodology was validated employing certified reference materials (Oyster tissue, Mussel, and Spiked skim milk powder) and the determined and certified values are in agreement (95% confidence level). The methodology was applied for trace levels determination of Cd in lyophilized mussel samples from the Chilean coast and non-fat milk powder, and a comparison made with graphite furnace electrothermal atomization (ETAAS) showed no statistically significant differences in results (95% confidence level)
author Bruhn,Carlos G.
Campos,Víctor H.
Díaz,Víctor P.
Cid,Hernán J.
Nóbrega,Joaquim A.
author_facet Bruhn,Carlos G.
Campos,Víctor H.
Díaz,Víctor P.
Cid,Hernán J.
Nóbrega,Joaquim A.
author_sort Bruhn,Carlos G.
title DETERMINATION OF Cd IN MUSSELS AND NON-FAT MILK POWDER BY FLOW INJECTION - FLAME ATOMIC ABSORPTION SPECTROPHOTOMETRY (FI-FAAS) WITH ON-LINE EXTRACTION BY A CHELATING RESIN
title_short DETERMINATION OF Cd IN MUSSELS AND NON-FAT MILK POWDER BY FLOW INJECTION - FLAME ATOMIC ABSORPTION SPECTROPHOTOMETRY (FI-FAAS) WITH ON-LINE EXTRACTION BY A CHELATING RESIN
title_full DETERMINATION OF Cd IN MUSSELS AND NON-FAT MILK POWDER BY FLOW INJECTION - FLAME ATOMIC ABSORPTION SPECTROPHOTOMETRY (FI-FAAS) WITH ON-LINE EXTRACTION BY A CHELATING RESIN
title_fullStr DETERMINATION OF Cd IN MUSSELS AND NON-FAT MILK POWDER BY FLOW INJECTION - FLAME ATOMIC ABSORPTION SPECTROPHOTOMETRY (FI-FAAS) WITH ON-LINE EXTRACTION BY A CHELATING RESIN
title_full_unstemmed DETERMINATION OF Cd IN MUSSELS AND NON-FAT MILK POWDER BY FLOW INJECTION - FLAME ATOMIC ABSORPTION SPECTROPHOTOMETRY (FI-FAAS) WITH ON-LINE EXTRACTION BY A CHELATING RESIN
title_sort determination of cd in mussels and non-fat milk powder by flow injection - flame atomic absorption spectrophotometry (fi-faas) with on-line extraction by a chelating resin
publisher Sociedad Chilena de Química
publishDate 2002
url http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0366-16442002000200008
work_keys_str_mv AT bruhncarlosg determinationofcdinmusselsandnonfatmilkpowderbyflowinjectionflameatomicabsorptionspectrophotometryfifaaswithonlineextractionbyachelatingresin
AT camposvictorh determinationofcdinmusselsandnonfatmilkpowderbyflowinjectionflameatomicabsorptionspectrophotometryfifaaswithonlineextractionbyachelatingresin
AT diazvictorp determinationofcdinmusselsandnonfatmilkpowderbyflowinjectionflameatomicabsorptionspectrophotometryfifaaswithonlineextractionbyachelatingresin
AT cidhernanj determinationofcdinmusselsandnonfatmilkpowderbyflowinjectionflameatomicabsorptionspectrophotometryfifaaswithonlineextractionbyachelatingresin
AT nobregajoaquima determinationofcdinmusselsandnonfatmilkpowderbyflowinjectionflameatomicabsorptionspectrophotometryfifaaswithonlineextractionbyachelatingresin
_version_ 1718438143982567424