Evaluation of a 3D Printed Female Anatomical Model for the Hands on Training of Trans-Obturator Tape (TOT) and Tension Free Vaginal Tape (TVT) Sling Procedures

SUMMARY: Trans-obturator tape (TOT) and tension free vaginal tape (TVT) procedures are efficient treatment options, which reduce the surgical complications and provide adequate support to urethra in case of increased abdominal pressure to prevent stress urinary incontinence (SUI). The aim of this st...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Tatar,Ilkan, Selçuk,Ilker, Huri,Emre
Lenguaje:English
Publicado: Sociedad Chilena de Anatomía 2020
Materias:
Acceso en línea:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-95022020000200292
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:scielo:S0717-95022020000200292
record_format dspace
spelling oai:scielo:S0717-950220200002002922020-02-03Evaluation of a 3D Printed Female Anatomical Model for the Hands on Training of Trans-Obturator Tape (TOT) and Tension Free Vaginal Tape (TVT) Sling ProceduresTatar,IlkanSelçuk,IlkerHuri,Emre 3D printed Female anatomical model Trans-obturator tape Tension free vaginal tape Stress urinary incontinence SUMMARY: Trans-obturator tape (TOT) and tension free vaginal tape (TVT) procedures are efficient treatment options, which reduce the surgical complications and provide adequate support to urethra in case of increased abdominal pressure to prevent stress urinary incontinence (SUI). The aim of this study is to evaluate the effect and efficacy of 3D printed female anatomical model on the training of TOT and TVT procedures. A 3D printed female anatomical model was produced for MedTRain3DModSim, Erasmus+ European Union project led by Turkey with the participation of Greece, Italy, Czech Republic and South Korea. Face and content validities of the model evaluated by the participants and the experts respectively. During two learning & teaching & training activities and a multiplier event of the project between 2016 and 2018; 41 medical students, 30 residents and 19 specialists of urology and gynecology were educated and performed TOT and TVT procedures with this model under the mentorship of 3 experts. All participants were assessed and scored for their achievement on both procedures with model according to 7 parameters by the experts. There was no statistical difference between the students and residents for each parameter. All the parameters of the students and specialists were statistically different. 3D anatomical models produced from real data and mimicking different types of tissues are suitable for basic anatomy education of students and residents, hands on training for junior surgeons before cadaveric courses in hybrid education system, surgical planning of the surgeons and informing the patients before the operation.info:eu-repo/semantics/openAccessSociedad Chilena de AnatomíaInternational Journal of Morphology v.38 n.2 20202020-04-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-95022020000200292en10.4067/S0717-95022020000200292
institution Scielo Chile
collection Scielo Chile
language English
topic 3D printed
Female anatomical model
Trans-obturator tape
Tension free vaginal tape
Stress urinary incontinence
spellingShingle 3D printed
Female anatomical model
Trans-obturator tape
Tension free vaginal tape
Stress urinary incontinence
Tatar,Ilkan
Selçuk,Ilker
Huri,Emre
Evaluation of a 3D Printed Female Anatomical Model for the Hands on Training of Trans-Obturator Tape (TOT) and Tension Free Vaginal Tape (TVT) Sling Procedures
description SUMMARY: Trans-obturator tape (TOT) and tension free vaginal tape (TVT) procedures are efficient treatment options, which reduce the surgical complications and provide adequate support to urethra in case of increased abdominal pressure to prevent stress urinary incontinence (SUI). The aim of this study is to evaluate the effect and efficacy of 3D printed female anatomical model on the training of TOT and TVT procedures. A 3D printed female anatomical model was produced for MedTRain3DModSim, Erasmus+ European Union project led by Turkey with the participation of Greece, Italy, Czech Republic and South Korea. Face and content validities of the model evaluated by the participants and the experts respectively. During two learning & teaching & training activities and a multiplier event of the project between 2016 and 2018; 41 medical students, 30 residents and 19 specialists of urology and gynecology were educated and performed TOT and TVT procedures with this model under the mentorship of 3 experts. All participants were assessed and scored for their achievement on both procedures with model according to 7 parameters by the experts. There was no statistical difference between the students and residents for each parameter. All the parameters of the students and specialists were statistically different. 3D anatomical models produced from real data and mimicking different types of tissues are suitable for basic anatomy education of students and residents, hands on training for junior surgeons before cadaveric courses in hybrid education system, surgical planning of the surgeons and informing the patients before the operation.
author Tatar,Ilkan
Selçuk,Ilker
Huri,Emre
author_facet Tatar,Ilkan
Selçuk,Ilker
Huri,Emre
author_sort Tatar,Ilkan
title Evaluation of a 3D Printed Female Anatomical Model for the Hands on Training of Trans-Obturator Tape (TOT) and Tension Free Vaginal Tape (TVT) Sling Procedures
title_short Evaluation of a 3D Printed Female Anatomical Model for the Hands on Training of Trans-Obturator Tape (TOT) and Tension Free Vaginal Tape (TVT) Sling Procedures
title_full Evaluation of a 3D Printed Female Anatomical Model for the Hands on Training of Trans-Obturator Tape (TOT) and Tension Free Vaginal Tape (TVT) Sling Procedures
title_fullStr Evaluation of a 3D Printed Female Anatomical Model for the Hands on Training of Trans-Obturator Tape (TOT) and Tension Free Vaginal Tape (TVT) Sling Procedures
title_full_unstemmed Evaluation of a 3D Printed Female Anatomical Model for the Hands on Training of Trans-Obturator Tape (TOT) and Tension Free Vaginal Tape (TVT) Sling Procedures
title_sort evaluation of a 3d printed female anatomical model for the hands on training of trans-obturator tape (tot) and tension free vaginal tape (tvt) sling procedures
publisher Sociedad Chilena de Anatomía
publishDate 2020
url http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-95022020000200292
work_keys_str_mv AT tatarilkan evaluationofa3dprintedfemaleanatomicalmodelforthehandsontrainingoftransobturatortapetotandtensionfreevaginaltapetvtslingprocedures
AT selcukilker evaluationofa3dprintedfemaleanatomicalmodelforthehandsontrainingoftransobturatortapetotandtensionfreevaginaltapetvtslingprocedures
AT huriemre evaluationofa3dprintedfemaleanatomicalmodelforthehandsontrainingoftransobturatortapetotandtensionfreevaginaltapetvtslingprocedures
_version_ 1718445136451469312