Diameter Measurements and Variations of the Hepatic Arterial System in Multidetector Computed Tomography Images
SUMMARY: Liver plays an important role in many events such as bile production, blood filtration and metabolic functions. The liver is supplied by the hepatic arterial system. The hepatic arterial system anatomy has a variable structure and the rate of variation is high. In our study, we aimed to det...
Guardado en:
Autores principales: | , , , , |
---|---|
Lenguaje: | English |
Publicado: |
Sociedad Chilena de Anatomía
2021
|
Materias: | |
Acceso en línea: | http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-95022021000300869 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:scielo:S0717-95022021000300869 |
---|---|
record_format |
dspace |
spelling |
oai:scielo:S0717-950220210003008692021-07-25Diameter Measurements and Variations of the Hepatic Arterial System in Multidetector Computed Tomography ImagesBilir,AbdulkadirFazliogullari,ZelihaKoplay,MustafaUnver-Dogan,NadireKarabulut,Ahmet Kagan Arterial system Liver Multidetector computed tomography Variation SUMMARY: Liver plays an important role in many events such as bile production, blood filtration and metabolic functions. The liver is supplied by the hepatic arterial system. The hepatic arterial system anatomy has a variable structure and the rate of variation is high. In our study, we aimed to determine the diameters and variation of the arteries supplying the liver with multidetector computed tomography images. In this study, hepatic arterial system variations of 500 cases whose abdominal region was imaged with multi- detector computed tomography were evaluated and the diameters of the related arteries were measured. The mean diameters of classical and variational anatomy were determined in this study. According to mean measurements of classical and variational anatomy were abdominal aorta 21.95 mm, celiac artery 7.2 mm, common hepatic artery 4.3 mm, proper hepatic artery 2.93 mm, right hepatic artery 2.92 mm, left hepatic artery 2.51 mm and abdominal aorta 21.85 mm, celiac artery 6.99 mm, common hepatic artery 5.07 mm, proper hepatic artery 3.83 mm, right hepatic artery 2.87 mm ve left hepatic artery 2.09 mm respectively. When evaluated in terms of variations, 85.6 % of the cases had branching according to Type I, 14.4 % of the cases had different branching patterns. Type III (87.5 %) was the most observed variation among them. As a result of the study, it was determined that the arterial diameters vary according to the state of variation and that the arterial diameter of men are greater than that of women.info:eu-repo/semantics/openAccessSociedad Chilena de AnatomíaInternational Journal of Morphology v.39 n.3 20212021-06-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-95022021000300869en10.4067/S0717-95022021000300869 |
institution |
Scielo Chile |
collection |
Scielo Chile |
language |
English |
topic |
Arterial system Liver Multidetector computed tomography Variation |
spellingShingle |
Arterial system Liver Multidetector computed tomography Variation Bilir,Abdulkadir Fazliogullari,Zeliha Koplay,Mustafa Unver-Dogan,Nadire Karabulut,Ahmet Kagan Diameter Measurements and Variations of the Hepatic Arterial System in Multidetector Computed Tomography Images |
description |
SUMMARY: Liver plays an important role in many events such as bile production, blood filtration and metabolic functions. The liver is supplied by the hepatic arterial system. The hepatic arterial system anatomy has a variable structure and the rate of variation is high. In our study, we aimed to determine the diameters and variation of the arteries supplying the liver with multidetector computed tomography images. In this study, hepatic arterial system variations of 500 cases whose abdominal region was imaged with multi- detector computed tomography were evaluated and the diameters of the related arteries were measured. The mean diameters of classical and variational anatomy were determined in this study. According to mean measurements of classical and variational anatomy were abdominal aorta 21.95 mm, celiac artery 7.2 mm, common hepatic artery 4.3 mm, proper hepatic artery 2.93 mm, right hepatic artery 2.92 mm, left hepatic artery 2.51 mm and abdominal aorta 21.85 mm, celiac artery 6.99 mm, common hepatic artery 5.07 mm, proper hepatic artery 3.83 mm, right hepatic artery 2.87 mm ve left hepatic artery 2.09 mm respectively. When evaluated in terms of variations, 85.6 % of the cases had branching according to Type I, 14.4 % of the cases had different branching patterns. Type III (87.5 %) was the most observed variation among them. As a result of the study, it was determined that the arterial diameters vary according to the state of variation and that the arterial diameter of men are greater than that of women. |
author |
Bilir,Abdulkadir Fazliogullari,Zeliha Koplay,Mustafa Unver-Dogan,Nadire Karabulut,Ahmet Kagan |
author_facet |
Bilir,Abdulkadir Fazliogullari,Zeliha Koplay,Mustafa Unver-Dogan,Nadire Karabulut,Ahmet Kagan |
author_sort |
Bilir,Abdulkadir |
title |
Diameter Measurements and Variations of the Hepatic Arterial System in Multidetector Computed Tomography Images |
title_short |
Diameter Measurements and Variations of the Hepatic Arterial System in Multidetector Computed Tomography Images |
title_full |
Diameter Measurements and Variations of the Hepatic Arterial System in Multidetector Computed Tomography Images |
title_fullStr |
Diameter Measurements and Variations of the Hepatic Arterial System in Multidetector Computed Tomography Images |
title_full_unstemmed |
Diameter Measurements and Variations of the Hepatic Arterial System in Multidetector Computed Tomography Images |
title_sort |
diameter measurements and variations of the hepatic arterial system in multidetector computed tomography images |
publisher |
Sociedad Chilena de Anatomía |
publishDate |
2021 |
url |
http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-95022021000300869 |
work_keys_str_mv |
AT bilirabdulkadir diametermeasurementsandvariationsofthehepaticarterialsysteminmultidetectorcomputedtomographyimages AT fazliogullarizeliha diametermeasurementsandvariationsofthehepaticarterialsysteminmultidetectorcomputedtomographyimages AT koplaymustafa diametermeasurementsandvariationsofthehepaticarterialsysteminmultidetectorcomputedtomographyimages AT unverdogannadire diametermeasurementsandvariationsofthehepaticarterialsysteminmultidetectorcomputedtomographyimages AT karabulutahmetkagan diametermeasurementsandvariationsofthehepaticarterialsysteminmultidetectorcomputedtomographyimages |
_version_ |
1718445201994809344 |