2-MERCAPTOETHYLAMINE AS A MASKING AGENT FOR THE COMPLEXOMETRIC DETERMINATION OF PALLADIUM(II) IN CATALYSTS, ALLOYS AND COMPLEXES
A simple, rapid and accurate complexometric method for the determination of palladium in the presence of other metal ions is described, based on the selective masking ability of 2-mercaptoethylamine (MEA) towards Pd(II). Palladium(II) along with other associated metal ions present in a given sample...
Guardado en:
Autores principales: | , |
---|---|
Lenguaje: | English |
Publicado: |
Sociedad Chilena de Química
2008
|
Materias: | |
Acceso en línea: | http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072008000300013 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:scielo:S0717-97072008000300013 |
---|---|
record_format |
dspace |
spelling |
oai:scielo:S0717-970720080003000132008-10-232-MERCAPTOETHYLAMINE AS A MASKING AGENT FOR THE COMPLEXOMETRIC DETERMINATION OF PALLADIUM(II) IN CATALYSTS, ALLOYS AND COMPLEXESSHETTY,PRAKASHNITYANANDA SHETTY,A palladium determination complexometry masking reagent 2-mercaptoethylamine A simple, rapid and accurate complexometric method for the determination of palladium in the presence of other metal ions is described, based on the selective masking ability of 2-mercaptoethylamine (MEA) towards Pd(II). Palladium(II) along with other associated metal ions present in a given sample solution is first complexed with an excess of EDTA and the surplus EDTA is titrated with zinc sulphate solution at pH 5-6 (acetic acid-sodium acétate buffer) using xylenol as indicator. A known excess of 0.2% aqueous solution of MEA is then added to displace EDTA from Pd(II)-EDTA complex and swirled well. The released EDTA is again titrated with zinc sulphate solution as before. The method works well in the range 2-20 mg of palladium(II) with the relative error ± 0.27 and the relative standard deviation < 0.35%. The effect of the presence of various diverse ions on the accuracy of the results has been studied. The method has been satisfactorily applied for the determination of palladium in catalysts, alloys and complexesinfo:eu-repo/semantics/openAccessSociedad Chilena de QuímicaJournal of the Chilean Chemical Society v.53 n.3 20082008-09-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072008000300013en10.4067/S0717-97072008000300013 |
institution |
Scielo Chile |
collection |
Scielo Chile |
language |
English |
topic |
palladium determination complexometry masking reagent 2-mercaptoethylamine |
spellingShingle |
palladium determination complexometry masking reagent 2-mercaptoethylamine SHETTY,PRAKASH NITYANANDA SHETTY,A 2-MERCAPTOETHYLAMINE AS A MASKING AGENT FOR THE COMPLEXOMETRIC DETERMINATION OF PALLADIUM(II) IN CATALYSTS, ALLOYS AND COMPLEXES |
description |
A simple, rapid and accurate complexometric method for the determination of palladium in the presence of other metal ions is described, based on the selective masking ability of 2-mercaptoethylamine (MEA) towards Pd(II). Palladium(II) along with other associated metal ions present in a given sample solution is first complexed with an excess of EDTA and the surplus EDTA is titrated with zinc sulphate solution at pH 5-6 (acetic acid-sodium acétate buffer) using xylenol as indicator. A known excess of 0.2% aqueous solution of MEA is then added to displace EDTA from Pd(II)-EDTA complex and swirled well. The released EDTA is again titrated with zinc sulphate solution as before. The method works well in the range 2-20 mg of palladium(II) with the relative error ± 0.27 and the relative standard deviation < 0.35%. The effect of the presence of various diverse ions on the accuracy of the results has been studied. The method has been satisfactorily applied for the determination of palladium in catalysts, alloys and complexes |
author |
SHETTY,PRAKASH NITYANANDA SHETTY,A |
author_facet |
SHETTY,PRAKASH NITYANANDA SHETTY,A |
author_sort |
SHETTY,PRAKASH |
title |
2-MERCAPTOETHYLAMINE AS A MASKING AGENT FOR THE COMPLEXOMETRIC DETERMINATION OF PALLADIUM(II) IN CATALYSTS, ALLOYS AND COMPLEXES |
title_short |
2-MERCAPTOETHYLAMINE AS A MASKING AGENT FOR THE COMPLEXOMETRIC DETERMINATION OF PALLADIUM(II) IN CATALYSTS, ALLOYS AND COMPLEXES |
title_full |
2-MERCAPTOETHYLAMINE AS A MASKING AGENT FOR THE COMPLEXOMETRIC DETERMINATION OF PALLADIUM(II) IN CATALYSTS, ALLOYS AND COMPLEXES |
title_fullStr |
2-MERCAPTOETHYLAMINE AS A MASKING AGENT FOR THE COMPLEXOMETRIC DETERMINATION OF PALLADIUM(II) IN CATALYSTS, ALLOYS AND COMPLEXES |
title_full_unstemmed |
2-MERCAPTOETHYLAMINE AS A MASKING AGENT FOR THE COMPLEXOMETRIC DETERMINATION OF PALLADIUM(II) IN CATALYSTS, ALLOYS AND COMPLEXES |
title_sort |
2-mercaptoethylamine as a masking agent for the complexometric determination of palladium(ii) in catalysts, alloys and complexes |
publisher |
Sociedad Chilena de Química |
publishDate |
2008 |
url |
http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072008000300013 |
work_keys_str_mv |
AT shettyprakash 2mercaptoethylamineasamaskingagentforthecomplexometricdeterminationofpalladiumiiincatalystsalloysandcomplexes AT nityanandashettya 2mercaptoethylamineasamaskingagentforthecomplexometricdeterminationofpalladiumiiincatalystsalloysandcomplexes |
_version_ |
1718445391296331776 |