POLY(SODIUM-10-UNDECYLENATE) AS PSEUDO-STATIONARY PHASE IN THE SEPARATION AND QUANTIFICATION OF POLYAROMATIC HYDROCARBONS BY MICELLAR ELECTROKINETIC CHROMATOGRAPHY

In this work we reported the synthesis of different molar mass fraction of poly(sodium-10-undecylenate) (PSU), and its subsequent utilization as pseudostationary phase in the separation of a mix of 4 polyaromatic hydrocarbons (PAHs); naphthalene (NAPH), fluorene (FLU), phenantrene (PHEN) and pyrene...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: PEREIRA,EDUARDO D, RIVAS,BERNABÉ L, PERIC,IVÁN, GALLEGOS,PAOLA, FIGUEROA,VALESKA
Lenguaje:English
Publicado: Sociedad Chilena de Química 2010
Acceso en línea:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072010000100008
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:scielo:S0717-97072010000100008
record_format dspace
spelling oai:scielo:S0717-970720100001000082010-04-29POLY(SODIUM-10-UNDECYLENATE) AS PSEUDO-STATIONARY PHASE IN THE SEPARATION AND QUANTIFICATION OF POLYAROMATIC HYDROCARBONS BY MICELLAR ELECTROKINETIC CHROMATOGRAPHYPEREIRA,EDUARDO DRIVAS,BERNABÉ LPERIC,IVÁNGALLEGOS,PAOLAFIGUEROA,VALESKAIn this work we reported the synthesis of different molar mass fraction of poly(sodium-10-undecylenate) (PSU), and its subsequent utilization as pseudostationary phase in the separation of a mix of 4 polyaromatic hydrocarbons (PAHs); naphthalene (NAPH), fluorene (FLU), phenantrene (PHEN) and pyrene (PYR). Concentration and molar mass fraction of PSU were the main variable studied. The analytical parameters; efficiency (N), selectivity (a), and resolution (R) were calculated to assess the separation capacity. The best conditions for the separation were achieved using a buffer composed by 12.5 mM of each sodium borate and sodium hydrogen phosphate, yielding pH 9.2 in ACN/H2O (40/60) solvent, using PSU of molar mass fraction 30-50 kDa in concentration of 0.25 g 100 mL-1. The applied voltage was 25 kV. Finally, Limit of Detection (LOD) and Limit of Quantification (LOQ) for 4 PAHs were calculated from the calibration curves in optimal separation conditions.info:eu-repo/semantics/openAccessSociedad Chilena de QuímicaJournal of the Chilean Chemical Society v.55 n.1 20102010-01-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072010000100008en10.4067/S0717-97072010000100008
institution Scielo Chile
collection Scielo Chile
language English
description In this work we reported the synthesis of different molar mass fraction of poly(sodium-10-undecylenate) (PSU), and its subsequent utilization as pseudostationary phase in the separation of a mix of 4 polyaromatic hydrocarbons (PAHs); naphthalene (NAPH), fluorene (FLU), phenantrene (PHEN) and pyrene (PYR). Concentration and molar mass fraction of PSU were the main variable studied. The analytical parameters; efficiency (N), selectivity (a), and resolution (R) were calculated to assess the separation capacity. The best conditions for the separation were achieved using a buffer composed by 12.5 mM of each sodium borate and sodium hydrogen phosphate, yielding pH 9.2 in ACN/H2O (40/60) solvent, using PSU of molar mass fraction 30-50 kDa in concentration of 0.25 g 100 mL-1. The applied voltage was 25 kV. Finally, Limit of Detection (LOD) and Limit of Quantification (LOQ) for 4 PAHs were calculated from the calibration curves in optimal separation conditions.
author PEREIRA,EDUARDO D
RIVAS,BERNABÉ L
PERIC,IVÁN
GALLEGOS,PAOLA
FIGUEROA,VALESKA
spellingShingle PEREIRA,EDUARDO D
RIVAS,BERNABÉ L
PERIC,IVÁN
GALLEGOS,PAOLA
FIGUEROA,VALESKA
POLY(SODIUM-10-UNDECYLENATE) AS PSEUDO-STATIONARY PHASE IN THE SEPARATION AND QUANTIFICATION OF POLYAROMATIC HYDROCARBONS BY MICELLAR ELECTROKINETIC CHROMATOGRAPHY
author_facet PEREIRA,EDUARDO D
RIVAS,BERNABÉ L
PERIC,IVÁN
GALLEGOS,PAOLA
FIGUEROA,VALESKA
author_sort PEREIRA,EDUARDO D
title POLY(SODIUM-10-UNDECYLENATE) AS PSEUDO-STATIONARY PHASE IN THE SEPARATION AND QUANTIFICATION OF POLYAROMATIC HYDROCARBONS BY MICELLAR ELECTROKINETIC CHROMATOGRAPHY
title_short POLY(SODIUM-10-UNDECYLENATE) AS PSEUDO-STATIONARY PHASE IN THE SEPARATION AND QUANTIFICATION OF POLYAROMATIC HYDROCARBONS BY MICELLAR ELECTROKINETIC CHROMATOGRAPHY
title_full POLY(SODIUM-10-UNDECYLENATE) AS PSEUDO-STATIONARY PHASE IN THE SEPARATION AND QUANTIFICATION OF POLYAROMATIC HYDROCARBONS BY MICELLAR ELECTROKINETIC CHROMATOGRAPHY
title_fullStr POLY(SODIUM-10-UNDECYLENATE) AS PSEUDO-STATIONARY PHASE IN THE SEPARATION AND QUANTIFICATION OF POLYAROMATIC HYDROCARBONS BY MICELLAR ELECTROKINETIC CHROMATOGRAPHY
title_full_unstemmed POLY(SODIUM-10-UNDECYLENATE) AS PSEUDO-STATIONARY PHASE IN THE SEPARATION AND QUANTIFICATION OF POLYAROMATIC HYDROCARBONS BY MICELLAR ELECTROKINETIC CHROMATOGRAPHY
title_sort poly(sodium-10-undecylenate) as pseudo-stationary phase in the separation and quantification of polyaromatic hydrocarbons by micellar electrokinetic chromatography
publisher Sociedad Chilena de Química
publishDate 2010
url http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072010000100008
work_keys_str_mv AT pereiraeduardod polysodium10undecylenateaspseudostationaryphaseintheseparationandquantificationofpolyaromatichydrocarbonsbymicellarelectrokineticchromatography
AT rivasbernabel polysodium10undecylenateaspseudostationaryphaseintheseparationandquantificationofpolyaromatichydrocarbonsbymicellarelectrokineticchromatography
AT pericivan polysodium10undecylenateaspseudostationaryphaseintheseparationandquantificationofpolyaromatichydrocarbonsbymicellarelectrokineticchromatography
AT gallegospaola polysodium10undecylenateaspseudostationaryphaseintheseparationandquantificationofpolyaromatichydrocarbonsbymicellarelectrokineticchromatography
AT figueroavaleska polysodium10undecylenateaspseudostationaryphaseintheseparationandquantificationofpolyaromatichydrocarbonsbymicellarelectrokineticchromatography
_version_ 1718445418994466816