VALIDATED RP-HPLC METHOD FOR QUANTITATION OF GLIQUIDONE IN PHARMACEUTICAL FORMULATION AND HUMAN SERUM
1. A simple isocratic reversed phase high performance liquid chromatographic (HPLC) method using C18 column with ultraviolet detection at 225 nm has been described for quantitative determination of gliquidone in formulation and human serum. The system is operated at room temperature using a mobile p...
Guardado en:
Autores principales: | , , , |
---|---|
Lenguaje: | English |
Publicado: |
Sociedad Chilena de Química
2010
|
Materias: | |
Acceso en línea: | http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072010000200002 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:scielo:S0717-97072010000200002 |
---|---|
record_format |
dspace |
spelling |
oai:scielo:S0717-970720100002000022010-09-06VALIDATED RP-HPLC METHOD FOR QUANTITATION OF GLIQUIDONE IN PHARMACEUTICAL FORMULATION AND HUMAN SERUMARAYNE,M. SAEEDSULTANA,NAJMAMIRZA,AGHA ZEESHANSIDDIQUI,FARHAN AHMED Gliquidone methylparaben UV detection RP-HPLC dosage formulation method validation 1. A simple isocratic reversed phase high performance liquid chromatographic (HPLC) method using C18 column with ultraviolet detection at 225 nm has been described for quantitative determination of gliquidone in formulation and human serum. The system is operated at room temperature using a mobile phase consisting of methanol: water (90:10) adjusted to pH 3.50 with phosphoric acid with a flow rate of 1 in Lmin-1. Methylparaben is successfully used as an internal standard. The assay is reproducible, linear (concentration range of 0.60-25 µmL-1) with correlation coefficient of 0.9999 and accurate (99.23 to 102.78%). The intra and inter run precision results are 1.14 and 1.32%. The LOD and LOQ values are 0.03 and 0.6 µmL-1, respectively There are no interfering peaks duetothe excipients present in the pharmaceutical tablet. Thus, the proposed method is simple and suitable for the analysis of active ingredient in tablet dosage form and human serum.info:eu-repo/semantics/openAccessSociedad Chilena de QuímicaJournal of the Chilean Chemical Society v.55 n.2 20102010-06-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072010000200002en10.4067/S0717-97072010000200002 |
institution |
Scielo Chile |
collection |
Scielo Chile |
language |
English |
topic |
Gliquidone methylparaben UV detection RP-HPLC dosage formulation method validation |
spellingShingle |
Gliquidone methylparaben UV detection RP-HPLC dosage formulation method validation ARAYNE,M. SAEED SULTANA,NAJMA MIRZA,AGHA ZEESHAN SIDDIQUI,FARHAN AHMED VALIDATED RP-HPLC METHOD FOR QUANTITATION OF GLIQUIDONE IN PHARMACEUTICAL FORMULATION AND HUMAN SERUM |
description |
1. A simple isocratic reversed phase high performance liquid chromatographic (HPLC) method using C18 column with ultraviolet detection at 225 nm has been described for quantitative determination of gliquidone in formulation and human serum. The system is operated at room temperature using a mobile phase consisting of methanol: water (90:10) adjusted to pH 3.50 with phosphoric acid with a flow rate of 1 in Lmin-1. Methylparaben is successfully used as an internal standard. The assay is reproducible, linear (concentration range of 0.60-25 µmL-1) with correlation coefficient of 0.9999 and accurate (99.23 to 102.78%). The intra and inter run precision results are 1.14 and 1.32%. The LOD and LOQ values are 0.03 and 0.6 µmL-1, respectively There are no interfering peaks duetothe excipients present in the pharmaceutical tablet. Thus, the proposed method is simple and suitable for the analysis of active ingredient in tablet dosage form and human serum. |
author |
ARAYNE,M. SAEED SULTANA,NAJMA MIRZA,AGHA ZEESHAN SIDDIQUI,FARHAN AHMED |
author_facet |
ARAYNE,M. SAEED SULTANA,NAJMA MIRZA,AGHA ZEESHAN SIDDIQUI,FARHAN AHMED |
author_sort |
ARAYNE,M. SAEED |
title |
VALIDATED RP-HPLC METHOD FOR QUANTITATION OF GLIQUIDONE IN PHARMACEUTICAL FORMULATION AND HUMAN SERUM |
title_short |
VALIDATED RP-HPLC METHOD FOR QUANTITATION OF GLIQUIDONE IN PHARMACEUTICAL FORMULATION AND HUMAN SERUM |
title_full |
VALIDATED RP-HPLC METHOD FOR QUANTITATION OF GLIQUIDONE IN PHARMACEUTICAL FORMULATION AND HUMAN SERUM |
title_fullStr |
VALIDATED RP-HPLC METHOD FOR QUANTITATION OF GLIQUIDONE IN PHARMACEUTICAL FORMULATION AND HUMAN SERUM |
title_full_unstemmed |
VALIDATED RP-HPLC METHOD FOR QUANTITATION OF GLIQUIDONE IN PHARMACEUTICAL FORMULATION AND HUMAN SERUM |
title_sort |
validated rp-hplc method for quantitation of gliquidone in pharmaceutical formulation and human serum |
publisher |
Sociedad Chilena de Química |
publishDate |
2010 |
url |
http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072010000200002 |
work_keys_str_mv |
AT araynemsaeed validatedrphplcmethodforquantitationofgliquidoneinpharmaceuticalformulationandhumanserum AT sultananajma validatedrphplcmethodforquantitationofgliquidoneinpharmaceuticalformulationandhumanserum AT mirzaaghazeeshan validatedrphplcmethodforquantitationofgliquidoneinpharmaceuticalformulationandhumanserum AT siddiquifarhanahmed validatedrphplcmethodforquantitationofgliquidoneinpharmaceuticalformulationandhumanserum |
_version_ |
1718445424412459008 |