STABILITY-INDICATING RP-HPLC METHOD FOR ANALYSIS OF ATORVASTATIN IN BULK DRUG, MARKETED TABLET AND NANOEMULSION FORMULATION

A simple, highly sensitive, isocratic stability indicating reversed phase-high performance liquid chromatography (RP-HPLC) method with UV detection at 247 nm was developed and validated for analysis of atorvastatin (AT). Retention time of the AT was found to be 4.02 min. A mobile phase consisting of...

Description complète

Enregistré dans:
Détails bibliographiques
Auteurs principaux: MUSTAFA,GULAM, AZEEM,ADNAN, AHMAD,FARHAN J, KHAN,ZEENAT I, SHAKEEL,FAIYAZ, TALEGAONKAR,SUSHMA
Langue:English
Publié: Sociedad Chilena de Química 2010
Sujets:
Accès en ligne:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072010000200008
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
Description
Résumé:A simple, highly sensitive, isocratic stability indicating reversed phase-high performance liquid chromatography (RP-HPLC) method with UV detection at 247 nm was developed and validated for analysis of atorvastatin (AT). Retention time of the AT was found to be 4.02 min. A mobile phase consisting of 0.05 M sodium phosphate buffer and methanol (3:7 v/v) pH 4.1 at flow rate of lµL/min was employed in this study. The calibration curves were linear with regression coefficient (r²) of 0.9997 ± 0.0014. The limits of detection (LOD) and the limits of quantification (LOQ) were found to be 0.20 and 0.60 µg/mL, respectively. The method was statistically validated in accordance with International conference on harmonization (ICH) guidelines. The proposed method was found sensitive, specific and was successfully applied for the estimation of atorvastatin in pharmaceutical formulations (bulk drug, tablet, nanoemulsion).