DEVELOPMENT AND VALIDATION OF A GC-NPD/micro-ECD METHOD USING DUAL COLUMN FOR THE DETERMINATION OF BENZODIAZEPINE IN HUMAN WHOLE BLOOD AND PLASMA

Four benzodiazepines flunitrazepam, nitrazepam, clonazepam, and alprazolam, have been analyzed from biological matrices by dual column gas chromatography using a nitrogen-phosphorus detector (NPD) and a micro-electron capture detector (m-ECD). The recoveries of the four benzodiazepines spiked into h...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: BRAVO,FELIPE, LOBOS,CLAUDIO, VENEGAS,KARINA, BENITES,JULIO
Lenguaje:English
Publicado: Sociedad Chilena de Química 2010
Materias:
Acceso en línea:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072010000400009
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:scielo:S0717-97072010000400009
record_format dspace
spelling oai:scielo:S0717-970720100004000092011-05-25DEVELOPMENT AND VALIDATION OF A GC-NPD/micro-ECD METHOD USING DUAL COLUMN FOR THE DETERMINATION OF BENZODIAZEPINE IN HUMAN WHOLE BLOOD AND PLASMABRAVO,FELIPELOBOS,CLAUDIOVENEGAS,KARINABENITES,JULIO Benzodiazepines gas chromatography nitrogen-phosphorus detector micro-electron capture detector Four benzodiazepines flunitrazepam, nitrazepam, clonazepam, and alprazolam, have been analyzed from biological matrices by dual column gas chromatography using a nitrogen-phosphorus detector (NPD) and a micro-electron capture detector (m-ECD). The recoveries of the four benzodiazepines spiked into human whole blood and plasma were 88.8 - 97.9 and 90.7 - 97.5%, respectively. The regression equations for the four benzodiazepines showed excellent linearity. The detection limits (LODs) were 0.14 - 0.95 ng/mL for whole blood and 0.13 - 0.93 ng/mL for plasma. The method is simple and sensitive for the determination of benzodiazepines in human whole blood and plasma, and may be useful in forensic science practice.info:eu-repo/semantics/openAccessSociedad Chilena de QuímicaJournal of the Chilean Chemical Society v.55 n.4 20102010-12-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072010000400009en10.4067/S0717-97072010000400009
institution Scielo Chile
collection Scielo Chile
language English
topic Benzodiazepines
gas chromatography
nitrogen-phosphorus detector
micro-electron capture detector
spellingShingle Benzodiazepines
gas chromatography
nitrogen-phosphorus detector
micro-electron capture detector
BRAVO,FELIPE
LOBOS,CLAUDIO
VENEGAS,KARINA
BENITES,JULIO
DEVELOPMENT AND VALIDATION OF A GC-NPD/micro-ECD METHOD USING DUAL COLUMN FOR THE DETERMINATION OF BENZODIAZEPINE IN HUMAN WHOLE BLOOD AND PLASMA
description Four benzodiazepines flunitrazepam, nitrazepam, clonazepam, and alprazolam, have been analyzed from biological matrices by dual column gas chromatography using a nitrogen-phosphorus detector (NPD) and a micro-electron capture detector (m-ECD). The recoveries of the four benzodiazepines spiked into human whole blood and plasma were 88.8 - 97.9 and 90.7 - 97.5%, respectively. The regression equations for the four benzodiazepines showed excellent linearity. The detection limits (LODs) were 0.14 - 0.95 ng/mL for whole blood and 0.13 - 0.93 ng/mL for plasma. The method is simple and sensitive for the determination of benzodiazepines in human whole blood and plasma, and may be useful in forensic science practice.
author BRAVO,FELIPE
LOBOS,CLAUDIO
VENEGAS,KARINA
BENITES,JULIO
author_facet BRAVO,FELIPE
LOBOS,CLAUDIO
VENEGAS,KARINA
BENITES,JULIO
author_sort BRAVO,FELIPE
title DEVELOPMENT AND VALIDATION OF A GC-NPD/micro-ECD METHOD USING DUAL COLUMN FOR THE DETERMINATION OF BENZODIAZEPINE IN HUMAN WHOLE BLOOD AND PLASMA
title_short DEVELOPMENT AND VALIDATION OF A GC-NPD/micro-ECD METHOD USING DUAL COLUMN FOR THE DETERMINATION OF BENZODIAZEPINE IN HUMAN WHOLE BLOOD AND PLASMA
title_full DEVELOPMENT AND VALIDATION OF A GC-NPD/micro-ECD METHOD USING DUAL COLUMN FOR THE DETERMINATION OF BENZODIAZEPINE IN HUMAN WHOLE BLOOD AND PLASMA
title_fullStr DEVELOPMENT AND VALIDATION OF A GC-NPD/micro-ECD METHOD USING DUAL COLUMN FOR THE DETERMINATION OF BENZODIAZEPINE IN HUMAN WHOLE BLOOD AND PLASMA
title_full_unstemmed DEVELOPMENT AND VALIDATION OF A GC-NPD/micro-ECD METHOD USING DUAL COLUMN FOR THE DETERMINATION OF BENZODIAZEPINE IN HUMAN WHOLE BLOOD AND PLASMA
title_sort development and validation of a gc-npd/micro-ecd method using dual column for the determination of benzodiazepine in human whole blood and plasma
publisher Sociedad Chilena de Química
publishDate 2010
url http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072010000400009
work_keys_str_mv AT bravofelipe developmentandvalidationofagcnpdmicroecdmethodusingdualcolumnforthedeterminationofbenzodiazepineinhumanwholebloodandplasma
AT lobosclaudio developmentandvalidationofagcnpdmicroecdmethodusingdualcolumnforthedeterminationofbenzodiazepineinhumanwholebloodandplasma
AT venegaskarina developmentandvalidationofagcnpdmicroecdmethodusingdualcolumnforthedeterminationofbenzodiazepineinhumanwholebloodandplasma
AT benitesjulio developmentandvalidationofagcnpdmicroecdmethodusingdualcolumnforthedeterminationofbenzodiazepineinhumanwholebloodandplasma
_version_ 1718445437139025920