PRECONCENTRATION OF Cd2+ IN DIFFERENT SAMPLES BY CHEMICALLY MODIFIED SIO2-DHAQ NANOPARTICLES
A new analytical method using 1,8-dihydroxyanthraquinone modified SiO2 nanoparticles as solid-phase extractant has been developed for the preconcentration of trace amounts of Cd2+ in different samples. Conditions of the analysis such as preconcentration factor, effect of pH, sample volume, shaking t...
Guardado en:
Autores principales: | , |
---|---|
Lenguaje: | English |
Publicado: |
Sociedad Chilena de Química
2011
|
Materias: | |
Acceso en línea: | http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072011000200005 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:scielo:S0717-97072011000200005 |
---|---|
record_format |
dspace |
spelling |
oai:scielo:S0717-970720110002000052011-09-01PRECONCENTRATION OF Cd2+ IN DIFFERENT SAMPLES BY CHEMICALLY MODIFIED SIO2-DHAQ NANOPARTICLESKAUR,ANUPREETGUPTA,USHA Chemically modified SiO-nanoparticles 1,8-dihydroxyanthraquinone Preconcentration Separation A new analytical method using 1,8-dihydroxyanthraquinone modified SiO2 nanoparticles as solid-phase extractant has been developed for the preconcentration of trace amounts of Cd2+ in different samples. Conditions of the analysis such as preconcentration factor, effect of pH, sample volume, shaking time, elution conditions and effects of interfering ions for the recovery of analyte were investigated. The adsorption capacity of nanometer SiO2-DHAQ was found to be 85.83 μmol/g at optimum pH and the detection limit (3σ) was 0.60ng/mL. The extractant showed rapid kinetic sorption. The adsorption equilibrium of Cd²+ on nanometer SiO2-DHAQ was achieved within 20 min. Adsorbed Cd²+ was easily eluted with 6mL of 1M hydrochloric acid. The maximum preconcentration factor has been found to be 66.70. The method was applied for the determination of trace amounts of Cd²+ in different samples.info:eu-repo/semantics/openAccessSociedad Chilena de QuímicaJournal of the Chilean Chemical Society v.56 n.2 20112011-01-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072011000200005en10.4067/S0717-97072011000200005 |
institution |
Scielo Chile |
collection |
Scielo Chile |
language |
English |
topic |
Chemically modified SiO-nanoparticles 1,8-dihydroxyanthraquinone Preconcentration Separation |
spellingShingle |
Chemically modified SiO-nanoparticles 1,8-dihydroxyanthraquinone Preconcentration Separation KAUR,ANUPREET GUPTA,USHA PRECONCENTRATION OF Cd2+ IN DIFFERENT SAMPLES BY CHEMICALLY MODIFIED SIO2-DHAQ NANOPARTICLES |
description |
A new analytical method using 1,8-dihydroxyanthraquinone modified SiO2 nanoparticles as solid-phase extractant has been developed for the preconcentration of trace amounts of Cd2+ in different samples. Conditions of the analysis such as preconcentration factor, effect of pH, sample volume, shaking time, elution conditions and effects of interfering ions for the recovery of analyte were investigated. The adsorption capacity of nanometer SiO2-DHAQ was found to be 85.83 μmol/g at optimum pH and the detection limit (3σ) was 0.60ng/mL. The extractant showed rapid kinetic sorption. The adsorption equilibrium of Cd²+ on nanometer SiO2-DHAQ was achieved within 20 min. Adsorbed Cd²+ was easily eluted with 6mL of 1M hydrochloric acid. The maximum preconcentration factor has been found to be 66.70. The method was applied for the determination of trace amounts of Cd²+ in different samples. |
author |
KAUR,ANUPREET GUPTA,USHA |
author_facet |
KAUR,ANUPREET GUPTA,USHA |
author_sort |
KAUR,ANUPREET |
title |
PRECONCENTRATION OF Cd2+ IN DIFFERENT SAMPLES BY CHEMICALLY MODIFIED SIO2-DHAQ NANOPARTICLES |
title_short |
PRECONCENTRATION OF Cd2+ IN DIFFERENT SAMPLES BY CHEMICALLY MODIFIED SIO2-DHAQ NANOPARTICLES |
title_full |
PRECONCENTRATION OF Cd2+ IN DIFFERENT SAMPLES BY CHEMICALLY MODIFIED SIO2-DHAQ NANOPARTICLES |
title_fullStr |
PRECONCENTRATION OF Cd2+ IN DIFFERENT SAMPLES BY CHEMICALLY MODIFIED SIO2-DHAQ NANOPARTICLES |
title_full_unstemmed |
PRECONCENTRATION OF Cd2+ IN DIFFERENT SAMPLES BY CHEMICALLY MODIFIED SIO2-DHAQ NANOPARTICLES |
title_sort |
preconcentration of cd2+ in different samples by chemically modified sio2-dhaq nanoparticles |
publisher |
Sociedad Chilena de Química |
publishDate |
2011 |
url |
http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072011000200005 |
work_keys_str_mv |
AT kauranupreet preconcentrationofcd2indifferentsamplesbychemicallymodifiedsio2dhaqnanoparticles AT guptausha preconcentrationofcd2indifferentsamplesbychemicallymodifiedsio2dhaqnanoparticles |
_version_ |
1718445445424873472 |