DEVELOPMENT AND VALIDATION OF A SOLID-PHASE EXTRACTION GAS CHROMATOGRAPHY-MASS SPECTROMETRY METHOD FOR THE SIMULTANEOUS QUANTIFICATION OF OPIOID DRUGS IN HUMAN WHOLE BLOOD AND PLASMA
A rapid, selective, sensitive, and specific method is presented to simultaneously quantify morphine, 6-monoacetylmorphine (6-MAM), codeine, heroin, fentanyl, and methadone in human whole blood and plasma. The drugs were extracted with phosphate buffer at pH 6, followed by solid-phase extraction (SPE...
Guardado en:
Autores principales: | , , |
---|---|
Lenguaje: | English |
Publicado: |
Sociedad Chilena de Química
2011
|
Materias: | |
Acceso en línea: | http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072011000300017 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:scielo:S0717-97072011000300017 |
---|---|
record_format |
dspace |
spelling |
oai:scielo:S0717-970720110003000172012-01-11DEVELOPMENT AND VALIDATION OF A SOLID-PHASE EXTRACTION GAS CHROMATOGRAPHY-MASS SPECTROMETRY METHOD FOR THE SIMULTANEOUS QUANTIFICATION OF OPIOID DRUGS IN HUMAN WHOLE BLOOD AND PLASMABRAVO,FELIPEGONZALEZ,DIEGOBENITES,JULIO Opiods gas chromatography mass selective detector solid-phase extraction A rapid, selective, sensitive, and specific method is presented to simultaneously quantify morphine, 6-monoacetylmorphine (6-MAM), codeine, heroin, fentanyl, and methadone in human whole blood and plasma. The drugs were extracted with phosphate buffer at pH 6, followed by solid-phase extraction (SPE) and quantification by GC/MS with electron impact ionization using helium as carrier gas. Quantification was performed based on nalorphine as internal standard (IS). The specificity, linearity, intra- and inter-assay precision and accuracy, and extraction recovery were fully evaluated. The limits of detection (LODs) were 0.40 - 7.63 ng/mL for whole blood and 0.80 - 32.00 ng/mL for plasma. The method is fast, simple, and accurate, with the sensitivity and specificity required in forensic and clinical toxicology.info:eu-repo/semantics/openAccessSociedad Chilena de QuímicaJournal of the Chilean Chemical Society v.56 n.3 20112011-01-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072011000300017en10.4067/S0717-97072011000300017 |
institution |
Scielo Chile |
collection |
Scielo Chile |
language |
English |
topic |
Opiods gas chromatography mass selective detector solid-phase extraction |
spellingShingle |
Opiods gas chromatography mass selective detector solid-phase extraction BRAVO,FELIPE GONZALEZ,DIEGO BENITES,JULIO DEVELOPMENT AND VALIDATION OF A SOLID-PHASE EXTRACTION GAS CHROMATOGRAPHY-MASS SPECTROMETRY METHOD FOR THE SIMULTANEOUS QUANTIFICATION OF OPIOID DRUGS IN HUMAN WHOLE BLOOD AND PLASMA |
description |
A rapid, selective, sensitive, and specific method is presented to simultaneously quantify morphine, 6-monoacetylmorphine (6-MAM), codeine, heroin, fentanyl, and methadone in human whole blood and plasma. The drugs were extracted with phosphate buffer at pH 6, followed by solid-phase extraction (SPE) and quantification by GC/MS with electron impact ionization using helium as carrier gas. Quantification was performed based on nalorphine as internal standard (IS). The specificity, linearity, intra- and inter-assay precision and accuracy, and extraction recovery were fully evaluated. The limits of detection (LODs) were 0.40 - 7.63 ng/mL for whole blood and 0.80 - 32.00 ng/mL for plasma. The method is fast, simple, and accurate, with the sensitivity and specificity required in forensic and clinical toxicology. |
author |
BRAVO,FELIPE GONZALEZ,DIEGO BENITES,JULIO |
author_facet |
BRAVO,FELIPE GONZALEZ,DIEGO BENITES,JULIO |
author_sort |
BRAVO,FELIPE |
title |
DEVELOPMENT AND VALIDATION OF A SOLID-PHASE EXTRACTION GAS CHROMATOGRAPHY-MASS SPECTROMETRY METHOD FOR THE SIMULTANEOUS QUANTIFICATION OF OPIOID DRUGS IN HUMAN WHOLE BLOOD AND PLASMA |
title_short |
DEVELOPMENT AND VALIDATION OF A SOLID-PHASE EXTRACTION GAS CHROMATOGRAPHY-MASS SPECTROMETRY METHOD FOR THE SIMULTANEOUS QUANTIFICATION OF OPIOID DRUGS IN HUMAN WHOLE BLOOD AND PLASMA |
title_full |
DEVELOPMENT AND VALIDATION OF A SOLID-PHASE EXTRACTION GAS CHROMATOGRAPHY-MASS SPECTROMETRY METHOD FOR THE SIMULTANEOUS QUANTIFICATION OF OPIOID DRUGS IN HUMAN WHOLE BLOOD AND PLASMA |
title_fullStr |
DEVELOPMENT AND VALIDATION OF A SOLID-PHASE EXTRACTION GAS CHROMATOGRAPHY-MASS SPECTROMETRY METHOD FOR THE SIMULTANEOUS QUANTIFICATION OF OPIOID DRUGS IN HUMAN WHOLE BLOOD AND PLASMA |
title_full_unstemmed |
DEVELOPMENT AND VALIDATION OF A SOLID-PHASE EXTRACTION GAS CHROMATOGRAPHY-MASS SPECTROMETRY METHOD FOR THE SIMULTANEOUS QUANTIFICATION OF OPIOID DRUGS IN HUMAN WHOLE BLOOD AND PLASMA |
title_sort |
development and validation of a solid-phase extraction gas chromatography-mass spectrometry method for the simultaneous quantification of opioid drugs in human whole blood and plasma |
publisher |
Sociedad Chilena de Química |
publishDate |
2011 |
url |
http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072011000300017 |
work_keys_str_mv |
AT bravofelipe developmentandvalidationofasolidphaseextractiongaschromatographymassspectrometrymethodforthesimultaneousquantificationofopioiddrugsinhumanwholebloodandplasma AT gonzalezdiego developmentandvalidationofasolidphaseextractiongaschromatographymassspectrometrymethodforthesimultaneousquantificationofopioiddrugsinhumanwholebloodandplasma AT benitesjulio developmentandvalidationofasolidphaseextractiongaschromatographymassspectrometrymethodforthesimultaneousquantificationofopioiddrugsinhumanwholebloodandplasma |
_version_ |
1718445451878858752 |