SCREEN-PRINTED ELECTRODE MODIFIED WITH SILVER HEXACY ANOFERRATE-NAFION® FOR ASCORBIC ACID DETERMINATION
A flow injection system using a new and/or re-used graphite screen-printed electrode modified with silver hexacyanoferrate and a Nafion® polymer layer (AgHCF/GSPE) was employed for the determination of ascorbic acid in orange juice and drugs samples. Both modified electrodes showed an initial sensit...
Guardado en:
Autores principales: | , , , , |
---|---|
Lenguaje: | English |
Publicado: |
Sociedad Chilena de Química
2011
|
Materias: | |
Acceso en línea: | http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072011000300018 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:scielo:S0717-97072011000300018 |
---|---|
record_format |
dspace |
spelling |
oai:scielo:S0717-970720110003000182012-01-11SCREEN-PRINTED ELECTRODE MODIFIED WITH SILVER HEXACY ANOFERRATE-NAFION® FOR ASCORBIC ACID DETERMINATIONMATTOS,I.LPADILLA,FZAGAL,J. HFALCAO,E.H.LSEGURA,R Silver hexacyanoferrate Ascorbic acid Food and pharmaceutical sample Re-used screen printed electrodes Flow amperometry A flow injection system using a new and/or re-used graphite screen-printed electrode modified with silver hexacyanoferrate and a Nafion® polymer layer (AgHCF/GSPE) was employed for the determination of ascorbic acid in orange juice and drugs samples. Both modified electrodes showed an initial sensitivity of 0.015 A.cm²־.M¹־, with a linear response over the range from 50 to 300 mg L¹ , relative standard deviations smaller than 2%, detection and quantification limits of c.a. 5.0 and 25.0 mg.L¹. The response of the electrodes was stable, with no variation of base line after 6-8 hours of continuous operation. With this system it is possible to measure 65-70 samples (20μΚ) per hour. By using 1.06 mg of AgNO3, 4.12 mg of K3Fe(CN)6, 50.5 mg of KNO3 and 800μL of HNO3, it is possible to obtain between 25 and 30 modified electrodes. The proposed system showed to be inexpensive, versatile, robust and suitable for industrial application. The surface morphology of the bare and/or modified graphite screen-printed electrode was characterized by scanning electron microscopy.info:eu-repo/semantics/openAccessSociedad Chilena de QuímicaJournal of the Chilean Chemical Society v.56 n.3 20112011-01-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072011000300018en10.4067/S0717-97072011000300018 |
institution |
Scielo Chile |
collection |
Scielo Chile |
language |
English |
topic |
Silver hexacyanoferrate Ascorbic acid Food and pharmaceutical sample Re-used screen printed electrodes Flow amperometry |
spellingShingle |
Silver hexacyanoferrate Ascorbic acid Food and pharmaceutical sample Re-used screen printed electrodes Flow amperometry MATTOS,I.L PADILLA,F ZAGAL,J. H FALCAO,E.H.L SEGURA,R SCREEN-PRINTED ELECTRODE MODIFIED WITH SILVER HEXACY ANOFERRATE-NAFION® FOR ASCORBIC ACID DETERMINATION |
description |
A flow injection system using a new and/or re-used graphite screen-printed electrode modified with silver hexacyanoferrate and a Nafion® polymer layer (AgHCF/GSPE) was employed for the determination of ascorbic acid in orange juice and drugs samples. Both modified electrodes showed an initial sensitivity of 0.015 A.cm²־.M¹־, with a linear response over the range from 50 to 300 mg L¹ , relative standard deviations smaller than 2%, detection and quantification limits of c.a. 5.0 and 25.0 mg.L¹. The response of the electrodes was stable, with no variation of base line after 6-8 hours of continuous operation. With this system it is possible to measure 65-70 samples (20μΚ) per hour. By using 1.06 mg of AgNO3, 4.12 mg of K3Fe(CN)6, 50.5 mg of KNO3 and 800μL of HNO3, it is possible to obtain between 25 and 30 modified electrodes. The proposed system showed to be inexpensive, versatile, robust and suitable for industrial application. The surface morphology of the bare and/or modified graphite screen-printed electrode was characterized by scanning electron microscopy. |
author |
MATTOS,I.L PADILLA,F ZAGAL,J. H FALCAO,E.H.L SEGURA,R |
author_facet |
MATTOS,I.L PADILLA,F ZAGAL,J. H FALCAO,E.H.L SEGURA,R |
author_sort |
MATTOS,I.L |
title |
SCREEN-PRINTED ELECTRODE MODIFIED WITH SILVER HEXACY ANOFERRATE-NAFION® FOR ASCORBIC ACID DETERMINATION |
title_short |
SCREEN-PRINTED ELECTRODE MODIFIED WITH SILVER HEXACY ANOFERRATE-NAFION® FOR ASCORBIC ACID DETERMINATION |
title_full |
SCREEN-PRINTED ELECTRODE MODIFIED WITH SILVER HEXACY ANOFERRATE-NAFION® FOR ASCORBIC ACID DETERMINATION |
title_fullStr |
SCREEN-PRINTED ELECTRODE MODIFIED WITH SILVER HEXACY ANOFERRATE-NAFION® FOR ASCORBIC ACID DETERMINATION |
title_full_unstemmed |
SCREEN-PRINTED ELECTRODE MODIFIED WITH SILVER HEXACY ANOFERRATE-NAFION® FOR ASCORBIC ACID DETERMINATION |
title_sort |
screen-printed electrode modified with silver hexacy anoferrate-nafion® for ascorbic acid determination |
publisher |
Sociedad Chilena de Química |
publishDate |
2011 |
url |
http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072011000300018 |
work_keys_str_mv |
AT mattosil screenprintedelectrodemodifiedwithsilverhexacyanoferratenafionforascorbicaciddetermination AT padillaf screenprintedelectrodemodifiedwithsilverhexacyanoferratenafionforascorbicaciddetermination AT zagaljh screenprintedelectrodemodifiedwithsilverhexacyanoferratenafionforascorbicaciddetermination AT falcaoehl screenprintedelectrodemodifiedwithsilverhexacyanoferratenafionforascorbicaciddetermination AT segurar screenprintedelectrodemodifiedwithsilverhexacyanoferratenafionforascorbicaciddetermination |
_version_ |
1718445452045582336 |