SCREEN-PRINTED ELECTRODE MODIFIED WITH SILVER HEXACY ANOFERRATE-NAFION® FOR ASCORBIC ACID DETERMINATION

A flow injection system using a new and/or re-used graphite screen-printed electrode modified with silver hexacyanoferrate and a Nafion® polymer layer (AgHCF/GSPE) was employed for the determination of ascorbic acid in orange juice and drugs samples. Both modified electrodes showed an initial sensit...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: MATTOS,I.L, PADILLA,F, ZAGAL,J. H, FALCAO,E.H.L, SEGURA,R
Lenguaje:English
Publicado: Sociedad Chilena de Química 2011
Materias:
Acceso en línea:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072011000300018
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:scielo:S0717-97072011000300018
record_format dspace
spelling oai:scielo:S0717-970720110003000182012-01-11SCREEN-PRINTED ELECTRODE MODIFIED WITH SILVER HEXACY ANOFERRATE-NAFION® FOR ASCORBIC ACID DETERMINATIONMATTOS,I.LPADILLA,FZAGAL,J. HFALCAO,E.H.LSEGURA,R Silver hexacyanoferrate Ascorbic acid Food and pharmaceutical sample Re-used screen printed electrodes Flow amperometry A flow injection system using a new and/or re-used graphite screen-printed electrode modified with silver hexacyanoferrate and a Nafion® polymer layer (AgHCF/GSPE) was employed for the determination of ascorbic acid in orange juice and drugs samples. Both modified electrodes showed an initial sensitivity of 0.015 A.cm²־.M¹־, with a linear response over the range from 50 to 300 mg L¹ , relative standard deviations smaller than 2%, detection and quantification limits of c.a. 5.0 and 25.0 mg.L¹. The response of the electrodes was stable, with no variation of base line after 6-8 hours of continuous operation. With this system it is possible to measure 65-70 samples (20μΚ) per hour. By using 1.06 mg of AgNO3, 4.12 mg of K3Fe(CN)6, 50.5 mg of KNO3 and 800μL of HNO3, it is possible to obtain between 25 and 30 modified electrodes. The proposed system showed to be inexpensive, versatile, robust and suitable for industrial application. The surface morphology of the bare and/or modified graphite screen-printed electrode was characterized by scanning electron microscopy.info:eu-repo/semantics/openAccessSociedad Chilena de QuímicaJournal of the Chilean Chemical Society v.56 n.3 20112011-01-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072011000300018en10.4067/S0717-97072011000300018
institution Scielo Chile
collection Scielo Chile
language English
topic Silver hexacyanoferrate
Ascorbic acid
Food and pharmaceutical sample
Re-used screen printed electrodes
Flow amperometry
spellingShingle Silver hexacyanoferrate
Ascorbic acid
Food and pharmaceutical sample
Re-used screen printed electrodes
Flow amperometry
MATTOS,I.L
PADILLA,F
ZAGAL,J. H
FALCAO,E.H.L
SEGURA,R
SCREEN-PRINTED ELECTRODE MODIFIED WITH SILVER HEXACY ANOFERRATE-NAFION® FOR ASCORBIC ACID DETERMINATION
description A flow injection system using a new and/or re-used graphite screen-printed electrode modified with silver hexacyanoferrate and a Nafion® polymer layer (AgHCF/GSPE) was employed for the determination of ascorbic acid in orange juice and drugs samples. Both modified electrodes showed an initial sensitivity of 0.015 A.cm²־.M¹־, with a linear response over the range from 50 to 300 mg L¹ , relative standard deviations smaller than 2%, detection and quantification limits of c.a. 5.0 and 25.0 mg.L¹. The response of the electrodes was stable, with no variation of base line after 6-8 hours of continuous operation. With this system it is possible to measure 65-70 samples (20μΚ) per hour. By using 1.06 mg of AgNO3, 4.12 mg of K3Fe(CN)6, 50.5 mg of KNO3 and 800μL of HNO3, it is possible to obtain between 25 and 30 modified electrodes. The proposed system showed to be inexpensive, versatile, robust and suitable for industrial application. The surface morphology of the bare and/or modified graphite screen-printed electrode was characterized by scanning electron microscopy.
author MATTOS,I.L
PADILLA,F
ZAGAL,J. H
FALCAO,E.H.L
SEGURA,R
author_facet MATTOS,I.L
PADILLA,F
ZAGAL,J. H
FALCAO,E.H.L
SEGURA,R
author_sort MATTOS,I.L
title SCREEN-PRINTED ELECTRODE MODIFIED WITH SILVER HEXACY ANOFERRATE-NAFION® FOR ASCORBIC ACID DETERMINATION
title_short SCREEN-PRINTED ELECTRODE MODIFIED WITH SILVER HEXACY ANOFERRATE-NAFION® FOR ASCORBIC ACID DETERMINATION
title_full SCREEN-PRINTED ELECTRODE MODIFIED WITH SILVER HEXACY ANOFERRATE-NAFION® FOR ASCORBIC ACID DETERMINATION
title_fullStr SCREEN-PRINTED ELECTRODE MODIFIED WITH SILVER HEXACY ANOFERRATE-NAFION® FOR ASCORBIC ACID DETERMINATION
title_full_unstemmed SCREEN-PRINTED ELECTRODE MODIFIED WITH SILVER HEXACY ANOFERRATE-NAFION® FOR ASCORBIC ACID DETERMINATION
title_sort screen-printed electrode modified with silver hexacy anoferrate-nafion® for ascorbic acid determination
publisher Sociedad Chilena de Química
publishDate 2011
url http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072011000300018
work_keys_str_mv AT mattosil screenprintedelectrodemodifiedwithsilverhexacyanoferratenafionforascorbicaciddetermination
AT padillaf screenprintedelectrodemodifiedwithsilverhexacyanoferratenafionforascorbicaciddetermination
AT zagaljh screenprintedelectrodemodifiedwithsilverhexacyanoferratenafionforascorbicaciddetermination
AT falcaoehl screenprintedelectrodemodifiedwithsilverhexacyanoferratenafionforascorbicaciddetermination
AT segurar screenprintedelectrodemodifiedwithsilverhexacyanoferratenafionforascorbicaciddetermination
_version_ 1718445452045582336